JBL ON TIME MICRO (serv.man7) EMC - CB Certificate ▷ View online
Page 9 of 106 Report No.: NTEK-2011NT1009314E
2.2 DESCRIPTION OF TEST MODES
To investigate the maximum EMI emission characteristics generates from EUT, the test
system was pre-scanning tested base on the consideration of following EUT operation
mode or test configuration mode which possible have effect on EMI emission level.
Each of these EUT operation mode(s) or test configuration mode(s) mentioned above
was evaluated respectively.
system was pre-scanning tested base on the consideration of following EUT operation
mode or test configuration mode which possible have effect on EMI emission level.
Each of these EUT operation mode(s) or test configuration mode(s) mentioned above
was evaluated respectively.
Pretest Mode
Description
Mode 1
Audio in
Mode 2
FM
Mode 3
Ipod Playing
For Conducted Test
Final Test Mode
Description
Mode 1
Audio in
Mode 2
FM
Mode 3
Ipod Playing
For Radiated Test
Final Test Mode
Description
Mode 1
Audio in
Mode 2
FM
Mode 3
Ipod Playing
For EMS Test
Final Test Mode
Description
Mode 1
Audio in
Page 10 of 106 Report No.: NTEK-2011NT1009314E
2.3 DESCRIPTION OF TEST SETUP
Mode 1
Mode 2
Mode 3
E-5
AM-anteen
AM-anteen
E-4
FM-antenna
FM-antenna
E-3
IPod
IPod
C-1
C-2
C-4
C-3
E-1
EUT
EUT
E-6
Remote control
Remote control
E-2
Switching Power
Supply
Switching Power
Supply
AC Plug
E-4
FM-antenna
FM-antenna
C-2
C-4
E-1
EUT
EUT
E-6
Remote control
Remote control
E-2
Switching Power
Supply
Switching Power
Supply
AC Plug
E-3
Ipod
Ipod
C-2
C-4
E-1
EUT
EUT
E-2
Switching Power
Supply
Switching Power
Supply
AC Plug
E-6
Remote control
Remote control
Page 11 of 106 Report No.: NTEK-2011NT1009314E
2.4 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
Item
Equipment
Mfr/Brand
Model/Type No.
FCC ID
Series No.
Note
E-1
AM/FM radio &
speaker dock for
ipod/iphone
JBL
Jbl on time micro
VOC N/A
EUT
E-2
Switching Power
Supply
JBL S024EV1200150
VOC 3JMB N/A
E-3 IPod E2-1
JBL
S024EV1200150
VOC N/A
N/A
E-4 FM-antenna
N/A
N/A
VOC N/A N/A
E-5
AM-antenna N/A N/A
VOC
N/A
N/A
E-6 Remote
control
N/A
Quantity
5
VOC SI02734 N/A
Item Shielded Type Ferrite Core
Length
Note
C-1 NO
NO
25cm
C-2 NO
YES
180cm
C-3 NO
NO
280cm
C-4 NO
NO
120cm
Note:
(1)
The support equipment was authorized by Declaration of Confirmation.
(2)
For detachable type I/O cable should be specified the length in cm in『Length』column.
(3)
“YES” is means “shielded” “with core”; “NO” is means “unshielded” “without core”.
Page 12 of 106 Report No.: NTEK-2011NT1009314E
2.5 MEASUREMENT INSTRUMENTS LIST
2.5.1 CONDUCTED TEST SITE
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1
LISN
R&S
ENV216
101313
Jul. 06, 2012
2
LISN
EMCO
3816/2
00042990
Jul. 06, 2012
3
50Ω Switch
ANRITSU CORP
MP59B
6200983704
Jul. 06, 2012
4
Test Cable
N/A
C01
N/A
Jul. 06, 2012
5
Test Cable
N/A
C02
N/A
Jul. 06, 2012
6
Test Cable
N/A
C03
N/A
Jul. 06, 2012
7
EMI Test Receiver
R&S
ESCI
101160
Jul. 06, 2012
8
Passive Voltage
Probe
ESH2-Z3
R&S
100196
Jul. 06, 2012
9
Triple-Loop
Antenna
EVERFINE
LIA-2
11020003
Jul. 06, 2012
10 Absorbing Clamp
R&S
MDS-21
100423
Jul. 08, 2012
2.5.2 RADIATED TEST SITE
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1
Bilog Antenna
TESEQ
CBL6111D
31216
Jul. 06, 2012
2
Test Cable
N/A
R-01
N/A
Jul. 06, 2012
3
Test Cable
N/A
R-02
N/A
Jul. 06, 2012
4
EMI Test Receiver
R&S
ESCI-7
101318
Jul. 06, 2012
5
Antenna Mast
EM
SC100_1
N/A
N/A
6
Turn Table
EM
SC100
060531
N/A
7
50Ω Switch
Anritsu Corp
MP59B
6200983705
Jul. 06, 2012
8 Spectrum Analyzer
Aglient
E4407B
MY45108040
Jul. 06. 2012
9
Horn Antenna
EM
EM-AH-1018
0
2011071402
Jul. 06. 2012
10
Amplifier
EM
EM-30180
060538
Jul. 06. 2012
2.5.3 HARMONICS AND FILCK
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1 Harmonic & Flicker
EM TEST
DPA500
0303-04
Jul. 06, 2012
2
AC Power Source
EM TEST
ACS500
0203-01
Jul. 06, 2012
2.5.4 ESD
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1
ESD Simulator
Thermo
MZ-15/EC
0502184
Nov. 24, 2011
2.5.5 EFT/BURST
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1
EFT/B Generator
EVERFINE
EMS61000-4
A-V2
1012005
Aug. 04, 2012
Click on the first or last page to see other ON TIME MICRO (serv.man7) service manuals if exist.