JBL ON TIME MICRO (serv.man7) EMC - CB Certificate ▷ View online
Page 5 of 106 Report No.: NTEK-2011NT1009314E
Table of Contents
Page
4.9 IMMUNITY TO RF FIELD (KEYED CARRIER) (S5)
88
4.9.1 TEST LIMIT
88
4.9.2 TEST PROCEDURE
88
4.9.3 TEST SETUP
88
4.9.4 TEST RESULTS
89
5 . EUT TEST PHOTO
92
ATTACHMENT PHOTOGRAPHS OF EUT
99
Page 6 of 106 Report No.: NTEK-2011NT1009314E
1. TEST SUMMARY
Test procedures according to the technical standards:
EMC Emission
Standard
Test Item
Limit
Judgment Remark
Conducted Emission
Class B
PASS
EN 55013:2001/A2:2006
Radiated Emission
Class B
PASS
EN61000-3-2:2006/A2:2009 Harmonic Current Emission Class A or D
NOTE (2)
PASS
EN 61000-3-3:2008
Voltage Fluctuations &
Flicker
------ PASS
EMC Immunity
Section
EN 55020:2007
Test Item
Performance
Criteria
Judgment Remark
EN 61000-4-2:2009
Electrostatic Discharge
B
PASS
EN61000-4-4:2004/A1:2010 Fast
transients
B PASS
EN 55020:2007
Input immunity to RF
voltages (differential mode)
(S1)
A PASS
EN 55020:2007
Immunity to induced
voltage test (in differential
mode)(S2a)
A PASS
EN 55020:2007
Immunity to RF voltages
(common mode) at
antenna terminals(S2b)
A PASS
EN 55020:2007
Immunity to ambient
electromagnetic fields (AM
Modulated Carrier)(S3)
A PASS
EN 55020:2007
Screening effectiveness of
the coaxial antenna
terminals(S4)
A PASS
EN 55020:2007
Immunity to RF field
(Keyed Carrier)(S5)
A PASS
NOTE:
(1)” N/A” denotes test is not applicable in this Test Report
(4) For client’s request and manual description, the test will not be executed.
Page 7 of 106 Report No.: NTEK-2011NT1009314E
1.1 TEST FACILITY
NTEK Testing Technology Co., Ltd.
NTEK Testing Technology Co., Ltd.
Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District,
Shenzhen P.R. China
.
FCC FRN Registration Number:238937; IC Registration Number:9270A-1
1.2 MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95 %。
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95 %。
A. Conducted Measurement :
Test Site Method
Measurement Frequency Range
U,(dB)
NOTE
NTEKC01 ANSI
150 KHz ~ 30MHz
3.2
B. Radiated Measurement :
Test Site Method
Measurement Frequency Range
U,(dB)
NOTE
NTEKA01 ANSI
30MHz ~ 1000MHz
4.7
1GHz
~6000GHz
5.0
Page 8 of 106 Report No.: NTEK-2011NT1009314E
2. GENERAL INFORMATION
2.1 GENERAL DESCRIPTION OF EUT
Equipment
AM/FM radio & speaker dock for ipod/iphone
Brand Name
JBL
Model Name.
Jbl on time™ micro
Serial No
N/A
Model Difference
N/A
Product Description
The EUT is a AM/FM radio & speaker dock for
ipod/iphone.
Based on the application, features, or specification
exhibited in User's Manual, the EUT is considered as an
ITE/Computing Device. More details of EUT technical
specification, please refer to the User's Manual.
32.768KHz
Operating frequency:
26MHz
FM ANT
AM ANT
AUX-IN
DC Port
FM ANT
AM ANT
AUX-IN
DC Port
Connecting I/O port:
IPod
Power Source
DC Voltage
Power Rating
DC 12V, 1.5A
Click on the first or last page to see other ON TIME MICRO (serv.man7) service manuals if exist.