DOWNLOAD JBL ON STAGE 200ID Service Manual ↓ Size: 1.6 MB | Pages: 103 in PDF or view online for FREE

Model
ON STAGE 200ID
Pages
103
Size
1.6 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-stage-200id.pdf
Date

JBL ON STAGE 200ID EMC - CB Certificate ▷ View online

 
 
- Page 56 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
2.5 
 
TABLE: limited power sources 
Circuit output tested: See below 
Measured Uoc (V) with all load circuits 
disconnected: See below 
 
I
sc 
(A) 
VA 
Measuring position 
Meas. 
Limit 
Meas. 
Limit 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
 
2.10.2 
TABLE: determination of operating voltage measurement  
 
Location 
Component  
From  
To  
Peak  Voltage (Vac) RMS Voltage (Vac)  Comments 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
 
2.10.3 and 
2.10.4 
TABLE: Clearance and creepage distance measurements 
Clearance (cl) and creepage 
distance (cr) at/of/between: 
U peak 
(V) 
U r.m.s.
 (V) 
Required cl
 (mm) 
cl 
 (mm) 
Required cr 
(mm) 
cr 
(mm) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
 
 
- Page 57 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
Copy of PCB, layout of tracing (not to scale): 
 
   
 
 
2.10.5 
TABLE: Distance through insulation measurements 
Distance through insulation (DTI) at/of: 
U peak
(V) 
U rms 
(V) 
Test 
voltage 
 (Vac) 
Required DTI
 (mm) 
DTI 
(mm) 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
 
 
- Page 58 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
4.3.8 TABLE: 
Batteries 
The tests of 4.3.8 are applicable only when appropriate battery 
data is not available 
 
 
Is it possible to install the battery in a reverse polarity position? 
 
 
Non-rechargeable batteries 
Rechargeable batteries 
Discharging 
Charging 
Discharging 
Reversed 
charging 
 
Meas. 
current
Manuf. 
Specs. 
Un-
intentional 
charging 
Meas. 
current
Manuf. 
Specs.
Meas. 
current 
Manuf. 
Specs. 
Meas. 
current
Manuf. 
Specs.
Max. 
current 
during 
normal 
condition 
 
 
 
 
 
 
 
 
 
Max. 
current 
during 
fault 
condition 
 
 
 
 
 
 
 
 
 
 
Test results: 
 
Verdict
- Chemical leaks 
 
 
- Explosion of the battery 
 
 
- Emission of flame or expulsion of molten metal 
 
 
- Electric strength tests of equipment after completion of tests 
 
 
supplementary information: 
 
 
 
 
- Page 59 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
4.5 
TABLE: Thermal requirements 
 
Supply voltage (V)  .....................
90V / 50Hz 
264V / 60Hz 
⎯ 
Maximum measured temperature T of 
part/at:: 
T (
°C) 
Allowed 
T
max
 (
°C)
Supplied 1KHz sine wave for speakers in computer speaker system and obtain 1/8 Maximum non-clipped 
output power, & charging Ipod (500mA 5V) 
Adaptor enclosure 
45.1 
48.5 
80.3 
Plug part of adaptor enclosure 
32.5 
32.7 
80.3 
PCB under IC U5 
79.4 
86.2 
90.3 
L2 81.4 
88.7 
115.3 
PCB near Q5 
70.5 
74.6 
90.3 
C13 69.6 
74.9 
90.3 
External enclosure of speaker 
57.6 
62.1 
80.3 
External enclosure near Ipod socket 
40 
40.8 
80.3 
External enclosure near on/off switch 
41.3 
43.5 
80.3 
Ambient 25.5 
25.3 
-- 
Having a specified maximum ambient temperature of 40°C, the maximum temperatures are calculated 
based upon a (minimum) test temperature of 25.3°C. Temp. limits are adjusted according to Cl. 1.4.12.3. 
Temperature limits include less 10K for thermocouple measurement method. 
Temperature T of winding: 
t
1
 (°C)
R
1
 (
Ω)
t
2
 (°C)
R
2
 (
Ω)
T (
°C) 
Allowed 
T
max
 (
°C)
Insulatio
n class
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
Page of 103