JBL ON STAGE 200ID EMC - CB Certificate ▷ View online
- Page 52 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.5.1
TABLE: Opto Electronic Devices
N
Distance
Manufacturer
Type
External
creepage
creepage
Through
insulation
Bridging
insulation
supplementary information:
1.6.2
TABLE: Electrical data (in normal conditions)
P
With Adaptor 700-0078-001/2/3/4/6/7
Supplied 1KHz sine wave for speakers in computer speaker system. Refer to the following remark for
condition of output.
condition of output.
Po (W)
Un (Vac)
input of
adapter
In (A)
input of
adapter
Pn (W)
input of
adapter
Un (Vdc)
input of unit
In(A)
input of unit
Pn (W)
input of unit
Speakers (4ohm x 2)
No Signal
90 / 50Hz
0.048
1.9
12.13
0.119
1.44
—
—
100 / 50Hz
0.045
2.0
12.13
0.119
1.44
—
—
240 / 50Hz
0.029
2.2
12.13
0.119
1.44
—
—
264 / 50Hz
0.028
2.3
12.13
0.119
1.44
—
—
90 / 60Hz
0.048
1.9
12.13
0.119
1.44
—
—
100 / 60Hz
0.045
2.0
12.13
0.119
1.44
—
—
240 / 60Hz
0.029
2.2
12.13
0.119
1.44
—
—
264 / 60Hz
0.028
2.3
12.13
0.119
1.44
—
—
Po (W)
Un (Vac)
input of
adapter
In (A)
input of
adapter
Pn (W)
input of
adapter
Un (Vdc)
input of unit
In(A)
input of unit
Pn (W)
input of unit
Speakers (4ohm x 2)
Maximum non-clipped output power & charging Ipod (500mA 5V)
90 / 50Hz
0.36
20.7
11.93
1.43
17.1
4.73 x2
—
100 / 50Hz
0.33
20.2
11.93
1.43
17.1
5.06 x2
—
- Page 53 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
240 / 50Hz
0.18
21.8
11.93
1.46
17.4
5.06 x2
—
264 / 50Hz
0.17
21.8
11.93
1.45
17.3
5.06 x2
—
90 / 60Hz
0.38
21.9
11.91
1.52
18.1
5.93 x2
—
100 / 60Hz
0.35
21.6
11.91
1.52
18.1
5.91 x2
—
240 / 60Hz
0.18
22.4
11.91
1.52
18.1
5.88 x2
—
264 / 60Hz
0.17
22.7
11.91
1.53
18.2
5.81 x2
—
Po (W)
Un (Vac)
input of
adapter
In (A)
input of
adapter
Pn (W)
input of
adapter
Un (Vdc)
input of unit
In(A)
input of unit
Pn (W)
input of unit
Speakers (4ohm x 2)
1/8 Maximum non-clipped output power & charging Ipod (500mA 5V)
90 / 50Hz
0.2
11.4
12
0.75
9
0.59 x2
—
100 / 50Hz
0.18
11.3
12
0.75
9
0.63 x2
—
240 / 50Hz
0.11
10.8
12
0.75
9
0.63 x2
—
264 / 50Hz
0.1
11.0
12
0.75
9
0.63 x2
—
90 / 60Hz
0.21
11.9
12
0.77
9.24
0.74 x2
—
100 / 60Hz
0.19
11.8
12
0.77
9.24
0.74 x2
—
240 / 60Hz
0.11
11.1
12.01
0.77
9.25
0.74 x2
—
264 / 60Hz
0.1
11.2
12.01
0.77
9.25
0.73 x2
—
supplementary information:
- Page 54 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.1.1.5 c1) TABLE: max. V, A, VA test
N
Voltage (rated)
(V)
Current (rated)
(A)
Voltage (max.)
(V)
Current (max.)
(A)
VA (max.)
(VA)
supplementary information:
The above measurements are the maximum values (max. V and max. A not obtained at the same time).
2.1.1.5 c2) TABLE: stored energy
N
Capacitance C (µF)
Voltage U (V)
Energy E (J)
supplementary information:
- Page 55 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.2
TABLE: evaluation of voltage limiting components in SELV circuits
N
Component (measured between)
max. voltage (V)
(normal operation)
Voltage Limiting Components
V peak
V d.c.
Fault test performed on voltage limiting components
Voltage measured (V) in SELV circuits
(V peak or V d.c.)
supplementary information:
S-c = Short circuit
2.4.2
Limited current circuit measurement
N
Location :
Condition
Voltage
(V)
Current
(mA)
Freq.
(kHz)
Limit
(mA)
Comments
supplementary information:
Click on the first or last page to see other ON STAGE 200ID service manuals if exist.