 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
1.5.1 
TABLE: Opto Electronic Devices 
Distance 
Manufacturer 
Type 
External 
creepage 
creepage 
Through 
insulation 
Bridging 
insulation 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
 
1.6.2 
TABLE: Electrical data (in normal conditions) 
With Adaptor 700-0078-001/2/3/4/6/7 
Supplied 1KHz sine wave for speakers in computer speaker system. Refer to the following remark for 
condition of output. 
Po (W) 
Un (Vac)  
input of 
adapter 
In (A)  
input of 
adapter 
Pn (W)  
input of 
adapter 
Un (Vdc) 
input of unit
In(A) 
input of unit
Pn (W)  
input of unit 
Speakers (4ohm x 2) 
No Signal 
90 / 50Hz 
0.048 
1.9 
12.13 
0.119 
1.44 
— 
— 
100 / 50Hz 
0.045 
2.0 
12.13 
0.119 
1.44 
— 
— 
240 / 50Hz 
0.029 
2.2 
12.13 
0.119 
1.44 
— 
— 
264 / 50Hz 
0.028 
2.3 
12.13 
0.119 
1.44 
— 
— 
90 / 60Hz 
0.048 
1.9 
12.13 
0.119 
1.44 
— 
— 
100 / 60Hz 
0.045 
2.0 
12.13 
0.119 
1.44 
— 
— 
240 / 60Hz 
0.029 
2.2 
12.13 
0.119 
1.44 
— 
— 
264 / 60Hz 
0.028 
2.3 
12.13 
0.119 
1.44 
— 
— 
Po (W) 
Un (Vac)  
input of 
adapter 
In (A)  
input of 
adapter 
Pn (W)  
input of 
adapter 
Un (Vdc) 
input of unit
In(A) 
input of unit
Pn (W)  
input of unit 
Speakers (4ohm x 2) 
Maximum non-clipped output power & charging Ipod (500mA 5V) 
90 / 50Hz 
0.36 
20.7 
11.93 
1.43 
17.1 
4.73 x2 
— 
100 / 50Hz 
0.33 
20.2 
11.93 
1.43 
17.1 
5.06 x2 
— 
 
 
- Page 53 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
240 / 50Hz 
0.18 
21.8 
11.93 
1.46 
17.4 
5.06 x2 
— 
264 / 50Hz 
0.17 
21.8 
11.93 
1.45 
17.3 
5.06 x2 
— 
90 / 60Hz 
0.38 
21.9 
11.91 
1.52 
18.1 
5.93 x2 
— 
100 / 60Hz 
0.35 
21.6 
11.91 
1.52 
18.1 
5.91 x2 
— 
240 / 60Hz 
0.18 
22.4 
11.91 
1.52 
18.1 
5.88 x2 
— 
264 / 60Hz 
0.17 
22.7 
11.91 
1.53 
18.2 
5.81 x2 
— 
Po (W) 
Un (Vac)  
input of 
adapter 
In (A)  
input of 
adapter 
Pn (W)  
input of 
adapter 
Un (Vdc) 
input of unit
In(A) 
input of unit
Pn (W)  
input of unit 
Speakers (4ohm x 2) 
1/8 Maximum non-clipped output power & charging Ipod (500mA 5V) 
90 / 50Hz 
0.2 
11.4 
12 
0.75 
0.59 x2 
— 
100 / 50Hz 
0.18 
11.3 
12 
0.75 
0.63 x2 
— 
240 / 50Hz 
0.11 
10.8 
12 
0.75 
0.63 x2 
— 
264 / 50Hz 
0.1 
11.0 
12 
0.75 
0.63 x2 
— 
90 / 60Hz 
0.21 
11.9 
12 
0.77 
9.24 
0.74 x2 
— 
100 / 60Hz 
0.19 
11.8 
12 
0.77 
9.24 
0.74 x2 
— 
240 / 60Hz 
0.11 
11.1 
12.01 
0.77 
9.25 
0.74 x2 
— 
264 / 60Hz 
0.1 
11.2 
12.01 
0.77 
9.25 
0.73 x2 
— 
supplementary information: 
 
 
 
 
- Page 54 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
2.1.1.5 c1)  TABLE: max. V, A, VA test  
Voltage (rated)  
(V) 
Current (rated) 
(A) 
Voltage (max.) 
(V) 
Current (max.) 
(A) 
VA (max.)  
(VA) 
 
 
 
 
 
supplementary information: 
The above measurements are the maximum values (max. V and max. A not obtained at the same time). 
 
 
2.1.1.5 c2)  TABLE: stored energy 
Capacitance C (µF) 
Voltage U (V) 
Energy E (J) 
 
 
 
 
 
 
supplementary information:  
 
 
 
 
- Page 55 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
2.2 
TABLE: evaluation of voltage limiting components in SELV circuits 
Component (measured between) 
max. voltage (V) 
(normal operation)
Voltage Limiting Components
 
V peak
V d.c. 
 
 
 
 
 
 
 
 
 
 
Fault test performed on voltage limiting components
Voltage measured (V) in SELV circuits 
(V peak or V d.c.) 
 
 
supplementary information: 
S-c = Short circuit 
 
 
2.4.2 
Limited current circuit measurement 
Location :  
Condition 
Voltage 
(V) 
Current 
(mA) 
Freq. 
(kHz) 
Limit 
(mA) 
Comments
 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 