Report Reference No.: 086-2101101501-000
TÜV SÜD Hong Kong Ltd.
 Test Report National and Group Differences for IEC 60950-1 2
nd
 Ed. Rev. 01 / 2010-04
DE
1.7.2.1
Germany (Gesetz über technische Arbeitsmittel
und Verbraucherprodukte (Geräte- und
Produktsicherheitsgesetz – GPSG) [Law on
technical labour equipment and consumer
products], of 6th January 2004, Section 2, Article
4, Clause (4), Item 2).
If for the assurance of safety and health certain
rules during use, amending or maintenance of a
technical labour equipment or readymade
consumer product are to be followed, a manual
in German language has to be delivered when
placing the product on the market.
Of this requirement, rules for use even only by
SERVICE PERSONS are not exempted.
N/A
DK
1.2.4.1  
In Denmark, certain types of Class I appliances
(see 3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted
into Danish socket-outlets.
N/A
1.7.5
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a,
when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet
shall be in accordance with Standard Sheet DK
1-1b or DK 1-5a.
N/A
1.7.5
For CLASS II EQUIPMENT the socket outlet
shall be in accordance with Standard Sheet DKA
1-4a.
N/A
3.2.1.1 
In Denmark, supply cords of single-phase
equipment having a rated current not
exceeding13 A shall be provided with a plug
according to the Heavy Current Regulations,
Section 107-2-D1.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with standard sheet DK 2-1a or DK
2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance with
the Heavy Current Regulations, Section 107-2-
D1 or EN 60309-2.
N/A
Page 10 of 33
Report Reference No.: 086-2101101501-000
TÜV SÜD Hong Kong Ltd.
 Test Report National and Group Differences for IEC 60950-1 2
nd
 Ed. Rev. 01 / 2010-04
FI
1.5.7.1
Resistors bridging BASIC INSULATION in
CLASS I PLUGGABLE EQUIPMENT TYPE A
must comply with the requirements in 1.5.7.2.
N/A
1.5.9.4 
The third dashed sentence is applicable only to
equipment as defined in 6.1.2.2 of this annex.
N/A
1.7.2.1 
CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed
mains socket-outlet.
The marking text shall be as follows:
“Laite on liitettävä suojakosketinpistorasiaan”
N/A
5.1.7.1 
TOUCH CURRENT measurement results
exceeding 3,5 mA r.m.s. are permitted only for
the following equipment:
  STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
o
  is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential
bonding has been applied, for example,
in telecommunication centre; and
o
  has provision for a permanently
connected PROTECTIVE EARTHING
CONDUCTOR; and
o
  is provided with instructions for the
installation of that conductor by a
SERVICE PERSON;
  STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
  STATIONARY 
PERMANENTLY
CONNECTED EQUIPMENT.
N/A
Page 11 of 33
Report Reference No.: 086-2101101501-000
TÜV SÜD Hong Kong Ltd.
 Test Report National and Group Differences for IEC 60950-1 2
nd
 Ed. Rev. 01 / 2010-04
6.1.2.1 
Add the following text between the first and
second paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
two layers of thin sheet material, each of
which shall pass the electric strength test
below, or
one layer having a distance through
insulation of at least 0,4 mm, which shall
pass the electric strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES
do not exist, if the component passes the electric
strength test in accordance with the compliance
clause below and in addition
passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5
kV multiplied by 1,6 (the electric strength
test of 2.10.10 shall be performed using 1,5
kV), and
is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test
voltage of 1,5 kV.
It is permitted to bridge this insulation with a
capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN
132400:1994, may bridge this insulation under
the following conditions:
the insulation requirements are satisfied by
having a capacitor classified Y3 as defined
by EN 132400, which in addition to the Y3
testing, is tested with an impulse test of 2,5
kV defined in EN 60950-1:2006, 6.2.2.1;
the additional testing shall be performed on
all the test specimens as described in EN
132400;
the impulse test of 2,5 kV is to be performed
before the endurance test in 132400, in the
sequence of tests as described in EN
132400.
N/A
Page 12 of 33
Report Reference No.: 086-2101101501-000
TÜV SÜD Hong Kong Ltd.
 Test Report National and Group Differences for IEC 60950-1 2
nd
 Ed. Rev. 01 / 2010-04
A capacitor classified Y3 according to EN
132400:1994, may bridge this insulation under
the following conditions:
the insulation requirements are satisfied by
having a capacitor classified Y3 as defined
by EN 132400, which in addition to the Y3
testing, is tested with an impulse test of 2,5
kV defined in EN 60950-1:2006, 6.2.2.1;
the additional testing shall be performed on
all the test specimens as described in EN
132400;
the impulse test of 2,5 kV is to be performed
before the endurance test in 132400, in the
sequence of tests as described in EN
132400.
6.1.2.2 
-  The 
exclusions 
are 
applicable 
for
PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT
TYPE B and equipment intended to be used
in a RESTRICTED ACCESS LOCATION
where equipotential bonding has been
applied, e.g. in a telecommunication centre,
and which has provision for a permanently
connected PROTECTIVE EARTHING
CONDUCTOR and is provided with
instructions for the installation of that
conductor by a SERVICE PERSON.
N/A
7.2
For requirements see 6.1.2.1 and 6.1.2.2 of
this annex. The term
TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
N/A
GB
2.6.3.3  
In the United Kingdom, the current rating of the
circuit shall be taken as 13 A, not 16 A.
N/A
2.7.1
In the United Kingdom, to protect against
excessive currents and short-circuits in the
PRIMARY CIRCUIT of DIRECT PLUG-IN
EQUIPMENT, tests according to 5.3 shall be
conducted, using an external protective device
rated 30 A or 32 A. If these tests fail, suitable
protective devices shall be included as integral
parts of the DIRECT PLUG-IN EQUIPMENT, so
that the requirements of 5.3 are met.
N/A