Report Reference No.: 086-2101101501-000
TÜV SÜD Hong Kong Ltd.
 Test Report National and Group Differences for IEC 60950-1 2
nd
 Ed. Rev. 01 / 2010-04
3.2.1.1 
In the United Kingdom, apparatus which is fitted
with a flexible cable or cord and is designed to
be connected to a mains socket conforming to
BS 1363 by means of that flexible cable or cord
and plug, shall be fitted with a ‘standard plug’ in
accordance with Statutory Instrument 1768:1994
- The Plugs and Sockets etc. (Safety)
Regulations 1994, unless exempted by those
regulations.
NOTE ‘Standard plug’ is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
N/A
3.2.5.1 
In the United Kingdom, a power supply cord with
conductor of 1,25 mm
2
 is allowed for equipment
with a rated current over 10 A and up to and
including 13 A.
N/A
3.3.4
In the United Kingdom, the range of conductor
sizes of flexible cords to be accepted by
terminals for equipment with a RATED
CURRENT of over 10 A up to and including 13 A
is:
•   1,25 mm
2
 to 1,5 mm
2
 nominal cross-
sectional area.
N/A
4.3.6
In the United Kingdom, the torque test is
performed using a socket outlet complying with
BS 1363 part 1:1995, including Amendment 1:
1997 and Amendment 2:2003 and the plug part
of DIRECT PLUG-IN EQUIPMENT shall be
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3,
12.9, 12.11, 12.12, 12.13, 12.16 and 12.17,
except that the test of 12.17 is performed at not
less than 125 °C. Where the metal earth pin is
replaced by an Insulated Shutter Opening Device
(ISOD), the requirements of clauses 22.2 and 23
also apply.
Direct plug-in integrated plug tested
should be considered during the
national approval.
N/A
ES
3.2.1.1  
In Spain, supply cords of single-phase equipment
having a rated current not exceeding 10 A shall
be provided with a plug according to UNE
20315:1994.
Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be
provided with a plug according to UNE-EN
50075:1993.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules, shall be provided with a plug in
accordance with standard UNE 20315:1994.
If poly-phase equipment is provided with a
supply cord with a plug, this plug shall be in
accordance with UNE-EN 60309-2
N/A
KR
Page 14 of 33
Report Reference No.: 086-2101101501-000
TÜV SÜD Hong Kong Ltd.
 Test Report National and Group Differences for IEC 60950-1 2
nd
 Ed. Rev. 01 / 2010-04
1.5.101 Addition
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305).
EMC report will be provided by
client separately.
N/A
8
EMC
Addition
The apparatus shall comply with the relevant
CISPR standards
N/A
NO
1.2.13.14 In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
N/A
1.5.7.1
In Finland, Norway and Sweden, resistors
bridging
BASIC INSULATION
in
CLASS I PLUGGABLE
EQUIPMENT TYPE A
must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
N/A
1.5.8
In Norway, due to the IT power system used (see
annex V, Figure V.7), capacitors are required to
be rated for the applicable line-to-line voltage
(230 V).
N/A
1.5.9.4  
In Finland, Norway and Sweden, the third dashed
sentence is applicable only to equipment as
defined in 6.1.2.2 of this annex.
N/A
1.7.2.1 
In Finland, Norway and Sweden, CLASS I
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall,
if safety relies on connection to protective earth
or if surge suppressors are connected between
the network terminals and accessible parts, have
a marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland:
"Laite on liitettävä suojamaadoituskoskettimilla
varustettuun pistorasiaan"
In Norway:
“Apparatet må tilkoples jordet stikkontakt”
In Sweden:
“Apparaten skall anslutas till jordat uttag”
N/A
Page 15 of 33
Report Reference No.: 086-2101101501-000
TÜV SÜD Hong Kong Ltd.
 Test Report National and Group Differences for IEC 60950-1 2
nd
 Ed. Rev. 01 / 2010-04
1.7.2.1
In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of
a cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator,
which may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective
earthing of the building installation through the
mains connection or through other equipment
with a connection to protective earthing – and
to a cable distribution system using coaxial
cable, may in some circumstances create a
fire hazard. Connection to a cable distribution
system has therefore to be provided through a
device providing electrical isolation below a
certain frequency range (galvanic isolator, see
EN 60728-11).”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr
– og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal
det ved tilkopling av utstyret til kabel-TV
nettet installeres en galvanisk isolator mellom
utstyret og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medf ra risk f r brand. F r att
undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk
isolator finnas mellan utrustningen och kabel-
TV nätet.”
N/A
2.2.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
N/A
2.3.2
In Finland, Norway and Sweden there are
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
N/A
2.3.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1
and 6.1.2.2 of this annex.
N/A
Page 16 of 33
Report Reference No.: 086-2101101501-000
TÜV SÜD Hong Kong Ltd.
 Test Report National and Group Differences for IEC 60950-1 2
nd
 Ed. Rev. 01 / 2010-04
2.10.5.13 In Finland, Norway and Sweden, there are
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.
N/A
5.1.7.1 
In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding 3,5
mA
r.m.s. are permitted only for the following
equipment:
  STATIONARY PLUGGABLE EQUIPMENT
TYPE A that is intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, for
example, in a telecommunication centre; and
  has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR;
and
  is provided with instructions for the
installation of that conductor by a SERVICE
PERSON;
  STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
  STATIONARY 
PERMANENTLY
CONNECTED EQUIPMENT.
N/A