Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
4.5 
TABLE: Thermal requirements 
 Supply 
voltage 
(V)  .......................... : 12VDC
12VDC
 
 
 
 
 
Ambient T
min 
(
C)  ............................. :
20.3 19.9 
 
 
 
 
 
Ambient T
max 
(
C)  ............................ :
22.0 22.3 
 
 
 
 
Maximum measured temperature T of part/at:: 
T (
C) 
Allowed 
T
max
 
(
C) 
DC inlet 
34.2 
35.7 
 
 
 
70 
I/O board CONN body 
46.1 
44.2 
 
 
 
90 
C666 body 
47.8 
47.2 
 
 
 
105 
L500 coil 
63.3 
64.8 
 
 
 
130 
L600 coil 
38.6 
62.2 
 
 
 
130 
PCB near D601 
38.2 
53.4 
 
 
 
130 
L502 coil 
39.7 
40.5 
 
 
 
130 
PCB near V101 
36.0 
36.3 
 
 
 
130 
L200 coil 
43.5 
40.6 
 
 
 
130 
PCB near U200 
44.8 
44.3 
 
 
 
130 
C206 body 
38.5 
39.2 
 
 
 
105 
Iphone connector 
40.6 
42.9 
 
 
 
90 
Battary 38.9 
42.4 
 
 
 
Ref 
Enclosure inside (Near Iphone inlet) 
33.5 
35.8 
 
 
 
Ref 
Enclosure outside(Near Iphone inlet) 
30.4 
30.2 
 
 
 
95 
Button 26.3 
27.5 
 
 
 
70 
Enclosure of AC adapter, near transformer 
39.4 
47.0 
 
 
 
95 
Output wire of AC adapter 
24.8 
24.6 
 
 
 
80 
Ambient 22.0 
22.8 
 
 
 
-- 
Supplementary information: 
Temperature T of winding: 
t
1
 (°C)
R
1
 (
)
t
2
 (°C)
R
2
 (
)
T (
C) 
Allowed 
T
max
 (
C)
Insulatio
n class
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Supplementary information: 
@: AC Adapter supply voltage: 90V/60Hz 
#: AC Adapter supply voltage: 264V/50Hz 
 
 
 
Page 41 of 44 
Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
4.5.5 
TABLE: Ball pressure test of thermoplastic parts 
N/A 
 
Allowed impression diameter (mm)  ..................... :
 2 mm 
 
Part 
Test temperature 
(
C) 
Impression diameter 
(mm) 
 
 
 
 
 
 
Supplementary information: 
 
 
4.7 
TABLE: Resistance to fire 
N/A 
Part 
Manufacturer of 
material 
Type of material 
Thickness 
(mm) 
Flammability
class 
Evidence 
 
 
 
 
 
 
 
 
 
 
 
 
Supplementary information: 
 
5.1 
TABLE: touch current measurement 
N/A 
 
Measured between: 
Measured  
(mA) 
Limit  
(mA) 
Comments/conditions 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
 
 
Page 42 of 44 
Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
5.2 
TABLE: Electric strength tests, impulse tests and voltage surge tests 
N/A 
Test voltage applied between: 
Voltage shape 
(AC, DC, 
impulse, surge) 
Test voltage 
(V) 
Breakdo
wn 
 Yes / No
Functional: 
 
 
 
 
 
 
 
 
Basic/supplementary: 
 
 
 
 
 
 
 
 
Reinforced: 
 
 
 
 
 
 
 
 
Supplementary information: 
 
 
5.3 
TABLE: Fault condition tests 
 
 
Ambient temperature (
C)  ................................... : 
 
 
 
Power source for EUT: Manufacturer, model/type, 
output rating  ......................................................... : 
 
 
Component  
No. 
Fault 
Supply 
voltage
 (V) 
Test 
time 
Fuse #
Fuse 
current
(A) 
Observation 
Battery  
S-C: polarities 
of battery 
240 1s 
The short circuit current dropped 
to 0A immediately, no component 
damage, no high temperature, no 
fire generation. 
Opening Block 
240  2h - 
0.268 
Normal work, no damage and no 
hazards. 
Speaker  
S-C 
240 
2.4h 
-- 
0.300 
Normal work, no damage and no 
hazards. 
Speaker 
Max. non-
clipped 
240 2.5h 
-- 
0.407 
Normal work, no damage and no 
hazards. 
Battery  
Overcharger  
240 
7h. 
-- 
-- 
Temperature stability and no 
damage, no hazards. 
Battery  
Over-
discharger  
240 7h. 
--  -- 
Temperature stability and no 
damage, no hazards. 
USB output  Overload 
240 
5.5h 
-- 
0.371 
USB overload to 1.7A, run for 
thermal equilibrium. Over 1.7A, 
USB load shut down. No hazard. 
 
Page 43 of 44 
Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
Iphone 
output 
Overload 240 
4.8h 
-- 
0.236 
Iphone overload to 4.0A, run for 
thermal equilibrium. Over 4.0A, 
Iphone load shut down. No 
hazard. 
Supplementary information: 
 
C.2 TABLE: 
transformers 
N/A 
 
Loc. 
Tested insulation 
Working 
voltage 
peak / V 
 
(2.10.2) 
Working 
voltage 
rms / V 
 
(2.10.2) 
Required 
electric 
strength 
 
(5.2) 
Required 
clearance / 
mm 
 
(2.10.3) 
Required 
creepage 
distance / 
mm 
(2.10.4) 
Required 
distance 
thr. insul. 
 
(2.10.5) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Loc. 
 
 
 
 
Tested insulation 
 
 
Test 
voltage/ 
Measured 
clearance / 
mm 
Measured 
creepage 
dist./ mm 
Measured 
distance 
thr. insul. / 
mm; 
number of 
layers 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
C.2 TABLE: 
transformers 
N/A 
Transformer 
 
 