JBL ON BEAT MINI EMC - CB Certificate ▷ View online
Page 4 of 44
Report No. : W13-950-006
TRF No. IEC60950_1C
Korea Testing Certification
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be authorized
by the respective NCBs that own these marks.
by the respective NCBs that own these marks.
(Additional requirements for markings. See 1.7 NOTE)
Page 5 of 44
Report No. : W13-950-006
TRF No. IEC60950_1C
Korea Testing Certification
Test item particulars ................................................... :
Equipment mobility..................................................... : [X] movable [] hand-held [] transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains ............................................ : [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
Operating condition .................................................... : [X] continuous
[] rated operating / resting time:
Access location ......................................................... : [X] operator accessible
[] restricted access location
Over voltage category (OVC) ................................... : [] OVC I [] OVC II [] OVC III [] OVC IV
[X] other: not directly connected to the mains
Mains supply tolerance (%) or absolute mains
supply values ............................................................ :
supply values ............................................................ :
±10%
Tested for IT power systems .................................... : [] Yes [X] No
IT testing, phase-phase voltage (V) .......................... :
Class of equipment ................................................... : [] Class I [] Class II [X] Class III
[] Not classified
Considered current rating of protective device as
part of the building installation (A) ............................ :
part of the building installation (A) ............................ :
Pollution degree (PD) ............................................... : [] PD 1 [X] PD 2 [] PD 3
IP protection class .................................................... : IP20
Altitude during operation (m) .................................... :
≤2000m
Altitude of test laboratory (m) .................................... : <500m
Mass of equipment (kg) ............................................ : 0.360
Possible test case verdicts:
- test case does not apply to the test object ................. : N/A
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ............................................ : 2013.01.14
Date(s) of performance of tests .................................... : 2013.01.15 to 2013.02.05
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Page 6 of 44
Report No. : W13-950-006
TRF No. IEC60950_1C
Korea Testing Certification
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ................................................................:
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ................................................................:
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... :
Harman International Industries, Incorporated
General product information:
The product is
Speaker dock for iPhone, iPad and iPod. Model no.: JBL OnBeat Mini.
It’s the 2*JBL full-range transducers. The amplifier used two powers: one AC power with 7 Watts*2,
other one battery power with 3.5 Watts*2.
The battery type is Lithium polymer with the rating 7.4V, 2000mAh. And the AC power model is
KSAS0451300323D5 with the input: 100-240V~, 50/60Hz, 1.2A, output: 13VDC, 3.23A. The AC power got
the CB certificate SG-OF-07650 which can meet the standard IEC 60950-1:2005 2Ed. + A1:2009.
Abbreviations used in the report:
-
normal
conditions
N.C.
- single fault conditions
S.F.C
-
functional
insulation
OP
-
basic
insulation
BI
-
double
insulation
DI
-
supplementary
insulation
SI
- between parts of opposite
polarity
BOP
-
reinforced
insulation
RI
Indicate used abbreviations (if any)
Page 7 of 44
Report No. : W13-950-006
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Korea Testing Certification
1 GENERAL
P
1.5 Components
P
1.5.1 General
P
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended tables 1.5.1)
P
1.5.2
Evaluation and testing of components
Certified components are
used in accordance with their
ratings, certifications and they
comply with applicable parts
of this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC
60950-1 and the relevant
component standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
used in accordance with their
ratings, certifications and they
comply with applicable parts
of this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC
60950-1 and the relevant
component standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
P
1.5.3
Thermal controls
No thermal controls
N/A
1.5.4 Transformers
No
transformers.
N/A
1.5.5 Interconnecting
cables
No
such cables provided.
N/A
1.5.6
Capacitors bridging insulation
No such capacitors provided.
N/A
1.5.7
Resistors bridging insulation
No such resistors.
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
N/A
1.5.9 Surge
suppressors
N/A
1.5.9.1 General
—
1.5.9.2
Protection of VDRs
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
N/A
Click on the first or last page to see other ON BEAT MINI service manuals if exist.