Report No. : W13-950-006 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
 
Copy of marking plate  
The artwork below may be only a draft. The use of certification marks on a product must be authorized 
by the respective NCBs that own these marks. 
(Additional requirements for markings. See 1.7 NOTE) 
 
 
 
Page 5 of 44 
Report No. : W13-950-006 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
 
Test item particulars ................................................... :  
Equipment mobility..................................................... : [X] movable     [] hand-held       [] transportable 
[] stationary  [] for building-in  [] direct plug-in 
Connection to the mains ............................................ : [] pluggable equipment   [] type A   [] type B 
[] permanent connection 
[] detachable power supply cord      
[] non-detachable power supply cord 
[X] not directly connected to the mains 
Operating condition .................................................... : [X] continuous 
[] rated operating / resting time:  
Access location  ......................................................... : [X] operator accessible 
[] restricted access location 
Over voltage category (OVC)  ................................... : [] OVC I     [] OVC II     [] OVC III     [] OVC IV 
[X] other: not directly connected to the mains
 
Mains supply tolerance (%) or absolute mains 
supply values  ............................................................ :
±10% 
Tested for IT power systems  .................................... : [] Yes     [X] No 
IT testing, phase-phase voltage (V)  .......................... :  
Class of equipment  ................................................... : [] Class I     [] Class II     [X] Class III      
[] Not classified 
Considered current rating of protective device as 
part of the building installation (A)  ............................ :
 
Pollution degree (PD)  ............................................... : [] PD 1     [X] PD 2     [] PD 3 
IP protection class  .................................................... : IP20 
Altitude during operation (m)  .................................... :
≤2000m 
Altitude of test laboratory (m)  .................................... : <500m 
Mass of equipment (kg)  ............................................ : 0.360 
Possible test case verdicts: 
 
- test case does not apply to the test object ................. : N/A  
- test object does meet the requirement....................... : P (Pass) 
- test object does not meet the requirement ................ : F (Fail) 
Testing .......................................................................... :  
Date of receipt of test item ............................................ : 2013.01.14 
Date(s) of performance of tests ....................................  : 2013.01.15 to 2013.02.05 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report a 
 comma / 
 point is used as the decimal separator. 
 
 
 
 
Page 6 of 44 
Report No. : W13-950-006 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: 
The application for obtaining a CB Test Certificate 
includes more than one factory location and a 
declaration from the Manufacturer stating that the 
sample(s) submitted for evaluation is (are) 
representative of the products from each factory has 
been provided ................................................................:
Yes 
 Not applicable 
 
When differences exist; they shall be identified in the General product information section. 
Name and address of factory (ies) .......................... :
Harman International Industries, Incorporated
 
 
General product information: 
       The product is 
Speaker dock for iPhone, iPad and iPod. Model no.: JBL OnBeat Mini. 
 
It’s the 2*JBL full-range transducers. The amplifier used two powers: one AC power with 7 Watts*2, 
other one battery power with 3.5 Watts*2.  
 
      The battery type is Lithium polymer with the rating 7.4V, 2000mAh. And the AC power model is 
KSAS0451300323D5 with the input: 100-240V~, 50/60Hz, 1.2A, output: 13VDC, 3.23A. The AC power got 
the CB certificate SG-OF-07650 which can meet the standard IEC 60950-1:2005 2Ed. + A1:2009. 
 
 
 
 
 
 
 
 
 
Abbreviations used in the report: 
 
normal 
conditions 
  N.C. 
   - single fault conditions 
 
S.F.C 
functional 
insulation 
 OP 
   - 
basic 
insulation 
  BI 
double 
insulation 
  DI 
   - 
supplementary 
insulation 
SI 
- between parts of opposite 
 
 
polarity 
   BOP 
   - 
reinforced 
insulation 
 RI 
 
Indicate used abbreviations (if any) 
 
 
 
 
 
 
 
 
 
 
Page 7 of 44 
Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
1 GENERAL 
 
1.5 Components 
1.5.1 General 
 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended tables 1.5.1) 
1.5.2 
Evaluation and testing of components 
Certified components are 
used in accordance with their 
ratings, certifications and they 
comply with applicable parts 
of this standard. 
Components not certified are 
used in accordance with their 
ratings and they comply with 
applicable parts of IEC 
60950-1 and the relevant 
component standard. 
Components, for which no 
relevant IEC-standard exists, 
have been tested under the 
conditions occurring in the 
equipment, using applicable 
parts of IEC 60950-1. 
1.5.3 
Thermal controls 
No thermal controls 
N/A 
1.5.4 Transformers 
No 
transformers. 
N/A 
1.5.5 Interconnecting 
cables 
No 
such cables provided.  
N/A 
1.5.6 
Capacitors bridging insulation  
No such capacitors provided. 
N/A 
1.5.7 
Resistors bridging insulation 
No such resistors.  
N/A 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
 N/A 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
 N/A 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable  
 N/A 
1.5.8 
Components in equipment for IT power systems 
 
N/A 
1.5.9 Surge 
suppressors 
 
N/A 
1.5.9.1 General 
 
 
1.5.9.2 
Protection of VDRs 
 
N/A 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
N/A 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 N/A 
Page of 71