Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
2.10.6.2 
Coated printed boards 
 
N/A 
2.10.6.3 
Insulation between conductors on the same inner 
surface of a printed board 
 N/A 
2.10.6.4 
Insulation between conductors on different layers of 
a printed board 
 N/A 
 
Distance through insulation 
 
N/A 
 
Number of insulation layers (pcs) ........................... : 
 
N/A 
2.10.7 
Component external terminations 
 
N/A 
2.10.8 
Tests on coated printed boards and coated 
components 
 N/A 
2.10.8.1 
Sample preparation and preliminary inspection 
 
N/A 
2.10.8.2 Thermal 
conditioning 
 
N/A 
2.10.8.3 
Electric strength test 
 
N/A 
2.10.8.4 
Abrasion resistance test 
 
N/A 
2.10.9 Thermal 
cycling 
 
N/A 
2.10.10 
Test for Pollution Degree 1 environment and 
insulating compound 
 N/A 
2.10.11 
Tests for semiconductor devices and cemented 
joints 
No such device used. 
N/A 
2.10.12 
Enclosed and sealed parts 
 
N/A 
 
 
WIRING, CONNECTIONS AND SUPPLY 
3.1 General 
3.1.1 
Current rating and overcurrent protection 
3.1.2 
Protection against mechanical damage 
Wires do not touch sharp 
edges which could damage 
the insulation and cause 
hazards. 
3.1.3 
Securing of internal wiring 
Wire ways are smooth and 
free from edges. Wires are 
adequately fixed to prevent 
excessive strain on wire and 
terminals and avoiding 
damage to the insulation of 
the conductors. 
 
Page 17 of 44 
Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
3.1.4 
Insulation of conductors 
Insulation on internal 
conductors is considered to 
be of adequate quality and 
suitable for the application 
and the working voltage 
involved.  
3.1.5 
Beads and ceramic insulators 
 
N/A 
3.1.6 
Screws for electrical contact pressure 
 
N/A 
3.1.7 
Insulating materials in electrical connections 
 
N/A 
3.1.8 
Self-tapping and spaced thread screws 
 
N/A 
3.1.9 
Termination of conductors 
 
 
10 N pull test 
All conductors are reliable 
secured. 
3.1.10 
Sleeving on wiring 
 
N/A 
 
3.2 
Connection to a mains supply 
N/A 
3.2.1 
Means of connection  
 
N/A 
3.2.1.1 
Connection to an a.c. mains supply 
 
N/A 
3.2.1.2 
Connection to a d.c. mains supply 
 
N/A 
3.2.2 
Multiple supply connections  
 
N/A 
3.2.3 
Permanently connected equipment 
 
N/A 
 
Number of conductors, diameter of cable and 
conduits (mm)  ....................................................... : 
 
 
3.2.4 Appliance 
inlets 
 
N/A 
3.2.5 
Power supply cords  
 
N/A 
3.2.5.1 
AC power supply cords 
 
N/A 
 Type 
 
...................................................................... 
 
 
 
Rated current (A), cross-sectional area (mm
2
),  
AWG  ..................................................................... : 
 
 
3.2.5.2 
DC power supply cords 
 
N/A 
3.2.6 
Cord anchorages and strain relief 
 
N/A 
 
Mass of equipment (kg), pull (N)   ......................... : 
 
 
 Longitudinal 
displacement (mm)  ........................... : 
 
 
3.2.7 
Protection against mechanical damage 
 
N/A 
3.2.8 Cord 
guards 
 
N/A 
 
Diameter or minor dimension D (mm); test mass (g) 
 ............................................................................... : 
 
 
 
Radius of curvature of cord (mm) .......................... : 
 
 
3.2.9 
Supply wiring space 
 
N/A 
 
Page 18 of 44 
Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
 
3.3 
Wiring terminals for connection of external conductors 
N/A 
3.3.1 
Wiring terminals 
Class III equipment (supplied 
by SELV). 
N/A 
3.3.2 
Connection of non-detachable power supply cords 
 
N/A 
3.3.3 Screw 
terminals 
 
N/A 
3.3.4 
Conductor sizes to be connected 
 
N/A 
 
Rated current (A), cord/cable type, cross-sectional 
area (mm
2
) ............................................................. : 
 
 
3.3.5 
Wiring terminal sizes 
 
N/A 
 
Rated current (A), type, nominal thread diameter 
(mm) ...................................................................... : 
 
 
3.3.6 
Wiring terminal design 
 
N/A 
3.3.7 
Grouping of wiring terminals 
 
N/A 
3.3.8 Stranded 
wire 
 
N/A 
 
3.4 
Disconnection from the mains supply 
N/A 
3.4.1 
General requirement 
Class III equipment (supplied 
by SELV). 
N/A 
3.4.2 Disconnect 
devices 
 
N/A 
3.4.3 
Permanently connected equipment 
 
N/A 
3.4.4 
Parts which remain energized 
 
N/A 
3.4.5 
Switches in flexible cords 
 
N/A 
3.4.6 
Number of poles - single-phase and d.c. equipment
 
N/A 
3.4.7 
Number of poles - three-phase equipment 
 
N/A 
3.4.8 
Switches as disconnect devices 
 
N/A 
3.4.9 
Plugs as disconnect devices 
 
N/A 
3.4.10 Interconnected 
equipment 
 
N/A 
3.4.11 
Multiple power sources 
 
N/A 
 
3.5 
Interconnection of equipment 
3.5.1 General 
requirements 
Considered. 
3.5.2 
Types of interconnection circuits  ............ : 
SELV circuit  
3.5.3 
ELV circuits as interconnection circuits  
No ELV. 
N/A 
3.5.4 
Data ports for additional equipment 
The USB port complied cl. 2.5 
LPS.  
 
 
Page 19 of 44 
Report No. : W13-950-006 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
Korea Testing Certification
 
4 PHYSICAL 
REQUIREMENTS 
N/A 
4.1 Stability 
N/A 
 
Angle of 10
 
 N/A 
 Test 
force 
(N)  ........................................................ :
 N/A 
 
4.2 Mechanical 
strength 
4.2.1 General 
 
 
Rack-mounted equipment.  
 
N/A 
4.2.2 
Steady force test, 10 N 
10N force applied to 
components 
 
4.2.3 
Steady force test, 30 N 
 
N/A 
4.2.4 
Steady force test, 250 N 
250N force applied to 
enclsoure  
4.2.5 Impact 
test 
 
N/A 
 Fall 
test 
 
N/A 
 Swing 
test 
 
N/A 
4.2.6 
Drop test; height (mm)  .......................................... :
Movable equipment N/A 
4.2.7 
Stress relief test 
70
C, 7h  
4.2.8 
Cathode ray tubes 
 
N/A 
 
Picture tube separately certified  ........................... :
(see  separate test report or  
attached certificate)    
N/A 
4.2.9 
High pressure lamps 
 
N/A 
4.2.10 
Wall or ceiling mounted equipment; force (N)  ...... :
 
N/A 
 
4.3 
Design and construction  
4.3.1 
Edges and corners 
All edges and corners are 
rounded and/or smoothed. 
4.3.2 
Handles and manual controls; force (N) ............. : 
No knobs, grips, handles, 
lever etc. 
N/A 
4.3.3 
Adjustable controls  
No hazardous adjustable 
controls. 
N/A 
4.3.4 
Securing of parts 
No connection likely to be 
exposed to mechanical stress 
are provided in unit. 
N/A 
4.3.5 
Connection by plugs and sockets 
No mismatch connector, plug 
or socket possible. 
N/A 
4.3.6 
Direct plug-in equipment 
 
N/A 
 Torque 
 ..................................................................  : 
 
 
Page of 71