JBL ON BEAT MINI EMC - CB Certificate ▷ View online
Page 16 of 44
Report No. : W13-950-006
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Korea Testing Certification
2.10.6.2
Coated printed boards
N/A
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
surface of a printed board
N/A
2.10.6.4
Insulation between conductors on different layers of
a printed board
a printed board
N/A
Distance through insulation
N/A
Number of insulation layers (pcs) ........................... :
N/A
2.10.7
Component external terminations
N/A
2.10.8
Tests on coated printed boards and coated
components
components
N/A
2.10.8.1
Sample preparation and preliminary inspection
N/A
2.10.8.2 Thermal
conditioning
N/A
2.10.8.3
Electric strength test
N/A
2.10.8.4
Abrasion resistance test
N/A
2.10.9 Thermal
cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
joints
No such device used.
N/A
2.10.12
Enclosed and sealed parts
N/A
3
WIRING, CONNECTIONS AND SUPPLY
P
3.1 General
P
3.1.1
Current rating and overcurrent protection
P
3.1.2
Protection against mechanical damage
Wires do not touch sharp
edges which could damage
the insulation and cause
hazards.
edges which could damage
the insulation and cause
hazards.
P
3.1.3
Securing of internal wiring
Wire ways are smooth and
free from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding
damage to the insulation of
the conductors.
free from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding
damage to the insulation of
the conductors.
P
Page 17 of 44
Report No. : W13-950-006
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Korea Testing Certification
3.1.4
Insulation of conductors
Insulation on internal
conductors is considered to
be of adequate quality and
suitable for the application
and the working voltage
involved.
conductors is considered to
be of adequate quality and
suitable for the application
and the working voltage
involved.
P
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
N/A
3.1.9
Termination of conductors
P
10 N pull test
All conductors are reliable
secured.
secured.
P
3.1.10
Sleeving on wiring
N/A
3.2
Connection to a mains supply
N/A
3.2.1
Means of connection
N/A
3.2.1.1
Connection to an a.c. mains supply
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
conduits (mm) ....................................................... :
3.2.4 Appliance
inlets
N/A
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Type
......................................................................
:
Rated current (A), cross-sectional area (mm
2
),
AWG ..................................................................... :
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ......................... :
Longitudinal
displacement (mm) ........................... :
3.2.7
Protection against mechanical damage
N/A
3.2.8 Cord
guards
N/A
Diameter or minor dimension D (mm); test mass (g)
............................................................................... :
............................................................................... :
Radius of curvature of cord (mm) .......................... :
3.2.9
Supply wiring space
N/A
Page 18 of 44
Report No. : W13-950-006
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Korea Testing Certification
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
Class III equipment (supplied
by SELV).
by SELV).
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3 Screw
terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm
area (mm
2
) ............................................................. :
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :
(mm) ...................................................................... :
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8 Stranded
wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1
General requirement
Class III equipment (supplied
by SELV).
by SELV).
N/A
3.4.2 Disconnect
devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10 Interconnected
equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1 General
requirements
Considered.
P
3.5.2
Types of interconnection circuits ............ :
SELV circuit
P
3.5.3
ELV circuits as interconnection circuits
No ELV.
N/A
3.5.4
Data ports for additional equipment
The USB port complied cl. 2.5
LPS.
LPS.
P
Page 19 of 44
Report No. : W13-950-006
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
Korea Testing Certification
4 PHYSICAL
REQUIREMENTS
N/A
4.1 Stability
N/A
Angle of 10
N/A
Test
force
(N) ........................................................ :
N/A
4.2 Mechanical
strength
P
4.2.1 General
P
Rack-mounted equipment.
N/A
4.2.2
Steady force test, 10 N
10N force applied to
components
components
P
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
250N force applied to
enclsoure
enclsoure
P
4.2.5 Impact
test
N/A
Fall
test
N/A
Swing
test
N/A
4.2.6
Drop test; height (mm) .......................................... :
Movable equipment N/A
4.2.7
Stress relief test
70
C, 7h
P
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ........................... :
(see separate test report or
attached certificate)
attached certificate)
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ...... :
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) ............. :
No knobs, grips, handles,
lever etc.
lever etc.
N/A
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N/A
4.3.4
Securing of parts
No connection likely to be
exposed to mechanical stress
are provided in unit.
exposed to mechanical stress
are provided in unit.
N/A
4.3.5
Connection by plugs and sockets
No mismatch connector, plug
or socket possible.
or socket possible.
N/A
4.3.6
Direct plug-in equipment
N/A
Torque
.................................................................. :