JBL ON BEAT MINI (serv.man2) EMC - CB Certificate ▷ View online
Page 64 of 99 Report No.: NTEK-2012DC1231016E
4.8.4 TEST RESULTS
EUT:
Speaker dock for iPhone, iPad
and iPod
and iPod
Model Name :
JBL OnBeat Mini
Temperature:
25 ℃
Relative Humidity: 60%
Pressure:
1010 hPa
Test Date :
2013-01-09
Test Mode :
Mode 1
Test Power :
DC 13V From Adapter AC 230V/50Hz
Test Mode
Test Level
Antenna
aspect
Duration
(s)
Perform
Criteria
Results
Judgment
Enclosure
1 A/m
X 60
s A A
Pass
Enclosure
1 A/m
Y 60
s A A
Pass
Enclosure
1 A/m
Z 60
s A A
Pass
Note:
1) N/A - denotes test is not applicable in this test report
2) Criteria A: There was no change operated with initial operating during the test.
3) Criteria B: The EUT function loss during the test, but self-recoverable after the test.
4) Criteria C: The system shut down during the test.
Page 65 of 99 Report No.: NTEK-2012DC1231016E
4.9 VOLTAGE INTERRUPTION/DIPS TESTING
4.9.1 TEST SPECIFICATION
Basic Standard:
IEC/EN 61000-4-11
Required Performance
B (For 100% Voltage Dips)
C (For 30% Voltage Dips)
C (For 100% Voltage Interruptions)
C (For 30% Voltage Dips)
C (For 100% Voltage Interruptions)
Test Duration Time:
Minimum three test events in sequence
Interval between Event:
Minimum ten seconds
Phase Angle:
0°/45°/90°/135°/180°/225°/270°/315°/360°
Test Cycle:
3 times
4.9.2 TEST PROCEDURE
The EUT shall be tested for each selected combination of test levels and duration with a
sequence of three dips/interruptions with intervals of 10 s minimum (between each test event).
Each representative mode of operation shall be tested. Abrupt changes in supply voltage shall
occur at zero crossings of the voltage waveform.
Each representative mode of operation shall be tested. Abrupt changes in supply voltage shall
occur at zero crossings of the voltage waveform.
4.9.3 TEST SETUP
Page 66 of 99 Report No.: NTEK-2012DC1231016E
4.9.4 TEST RESULTS
EUT:
Speaker dock for iPhone, iPad
and iPod
and iPod
Model Name :
JBL OnBeat Mini
Temperature:
25 ℃
Relative Humidity: 60%
Pressure:
1010 hPa
Test Date :
2013-01-09
Test Mode :
Mode 1
Test Power :
DC 13V From Adapter AC 230V/50Hz
Interruption & Dips
Duration
(T)
Perform
Criteria
Results
Judgment
Voltage dip 100%
0.5
B
B PASS
Voltage dip 30%
25
C B
PASS
Voltage dip 100%
250
C C
PASS
Note:
1) N/A - denotes test is not applicable in this test report.
2) Criteria A: There was no change operated with initial operating during the test.
3) Criteria B: The EUT function loss during the test, but self-recoverable after the test.
4) Criteria C: The system shut down during the test.
Page 67 of 99 Report No.: NTEK-2012DC1231016E
4.10 INPUT IMMUNITY TO RF VOLTAGES (DIFFERENTIAL MODE) (S1)
4.10.1 TEST LIMIT
Click on the first or last page to see other ON BEAT MINI (serv.man2) service manuals if exist.