Page 60 of 99                      Report No.: NTEK-2012DC1231016E 
 
 
                                                                                                                                                                   
 
4.7.3 TEST SETUP 
 
NOTE: 
FLOOR-STANDING EQUIPMENT 
The equipment to be tested is placed on an insulating support of 0.1 meters height above a 
ground reference plane. All relevant cables shall be provided with the appropriate coupling and 
decoupling devices at a distance between 0.1 meters and 0.3 meters from the projected geometry 
of the EUT on the ground reference plane. 
                                                   
                                                       
Page 61 of 99                      Report No.: NTEK-2012DC1231016E 
 
 
                                                                                                                                                                   
 
4.7.4 TEST RESULTS 
 
EUT: 
Speaker dock for iPhone, iPad 
and iPod 
Model Name  : 
JBL OnBeat Mini 
Temperature: 
25 ℃ 
Relative Humidity: 60% 
Pressure: 
1010 hPa 
Test Date : 
2013-01-09 
Test Mode  : 
Mode 1 
Test Power : 
DC 13V From Adapter AC 230V/50Hz 
 
Test Ports 
(Mode) 
Freq. Range 
MHz) 
Field Strength
Perform. 
Criteria 
Results 
Judgment 
Input/ Output 
AC. Power Port 
0.15 ---80 
A A 
PASS 
Input/ Output 
DC. Power Port 
0.15 --- 80 
A N/A 
N/A 
Signal Line 
0.15 --- 80 
3V(rms) 
AM Modulated
1000Hz, 80%
A N/A 
N/A 
 
 
Note:  
 
1) N/A - denotes test is not applicable in this Test Report. 
 
2) Criteria A: There was no change operated with initial operating during the test. 
 
3) Criteria B: The EUT function loss during the test, but self-recoverable after the test. 
 
4) Criteria C: The system shut down during the test. 
 
 
                                                   
                                                       
Page 62 of 99                      Report No.: NTEK-2012DC1231016E 
 
 
                                                                                                                                                                   
 
4.8  POWER FREQUENCY MAGNETIC FIELD TESTING   
 
4.8.1 TEST SPECIFICATION 
 
 
Basic Standard: 
IEC/EN 61000-4-8 
Required Performance 
Frequency Range: 
50Hz 
Field Strength: 
1 A/m 
Observation Time: 
1 minute 
Inductance Coil: 
Rectangular type, 1mx1m 
 
 
4.8.2 TEST PROCEDURE 
 The EUT and support equipment, are placed on a table that is 0.8 meter above a metal ground 
plane measured 1m*1m min. and 0.65mm thick min.   
The other condition as following manner: 
a. The equipment cabinets shall be connected to the safety earth directly on the GRP via the 
earth terminal of the EUT. 
b. The cables supplied or recommended by the equipment manufacturer shall be used. 1 meter 
of all cables used shall be exposed to the magnetic field. 
  
  
 
 
 
 
                                                   
                                                       
Page 63 of 99                      Report No.: NTEK-2012DC1231016E 
 
 
                                                                                                                                                                   
 
4.8.3 TEST SETUP 
Note: 
TABLE-TOP EQUIPMENT   
 
The equipment shall be subjected to the test magnetic field by using the induction coil of standard 
dimension (1 m x 1 m). The induction coil shall then be rotated by 90 degrees in order to expose 
the EUT to the test field with different orientations. 
FLOOR-STANDING EQUIPMENT 
The equipment shall be subjected to the test magnetic field by using induction coils of suitable 
dimensions. The test shall be repeated by moving and shifting the induction coils, in order to test 
the whole volume of the EUT for each orthogonal direction. The test shall be repeated with the coil 
shifted to different positions along the side of the EUT, in steps corresponding to 50 % of the 
shortest side of the coil. The induction coil shall then be rotated by 90 degrees in order to expose 
the EUT to the test field with different orientations. 