JBL ES 150PW (serv.man3) EMC - CB Certificate ▷ View online
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
1
1. TEST REPORT CERTIFICATION
Applicant: Meiloon Industrial Co., Ltd.
Address: No.77, Lane 1775, Chuen-Ryh Road, Taoyuan City, Taiwan
EUT: Wireless Speaker Amplifier
Trade Name: JBL
Model No. : ES150PW/230
Test Standards: EN 55020:2007
IEC 61000-4-2:1995+A1:1998+A2:2000
IEC 61000-4-3:2006+A1:2007
IEC 61000-4-4:2004
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
2
2. SUMMARY OF TEST RESULTS
2.1 Test Result
2.1 Test Result
The EUT has been tested according to the following specifications:
IMMUNITY(EN 55020: 2007)
Standard
Test Type
Result
Remarks
Input immunity
N/A
The immunity test at antenna
input terminal of EUT.
The performance criteria is A
input terminal of EUT.
The performance criteria is A
Immunity to Induced voltages PASS
The immunity test at Audio
and mains terminal of EUT by
CDN.
The performance criteria is A
and mains terminal of EUT by
CDN.
The performance criteria is A
Immunity to RF voltage at
antenna terminal
antenna terminal
N/A
The immunity test at antenna
input terminal of EUT by
CDN.
The performance criteria is A
input terminal of EUT by
CDN.
The performance criteria is A
Immunity from radiated
fields
fields
PASS
The immunity test at enclosure
of EUT by open strip line.
The performance criteria is A
of EUT by open strip line.
The performance criteria is A
EN 55020:2007
Screening effectiveness
N/A
The screening effectiveness is
≧
≧
50dB
EN 55020:2007
IEC 61000-4-2
IEC 61000-4-2
Electrostatic discharge
immunity test
immunity test
PASS
Contact discharge up to ±4 kV
Air discharge up to ±8 kV
The performance criteria is B
Air discharge up to ±8 kV
The performance criteria is B
EN 55020:2007
IEC 61000-4-3
IEC 61000-4-3
Radiated, radio-frequency,
electromagnetic field
immunity test
electromagnetic field
immunity test
PASS
900MHz
(duty cycle 1/8 , 217Hz
repetition frequency): 3V/m
The performance criteria is A
(duty cycle 1/8 , 217Hz
repetition frequency): 3V/m
The performance criteria is A
EN 55020:2007
IEC 61000-4-4
IEC 61000-4-4
Electrical fast transient / burst
immunity test.
immunity test.
PASS
±
0.5 kV, ±1 kV(AC Input)
The performance criteria is B
The above equipment has been tested by Telecom Technology Center, and found
compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true
and accurate accounts of the measurements of the sample’s EMC characteristics under
the conditions specified in this report.
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
3
2.2 Description of EUT
EUT
Wireless Speaker Amplifier
Trade Name
JBL
Model No.
ES150PW/230
Serial No.
N/A
Product Description
More details of EUT Technical specification please
refer to the User’s Manual
refer to the User’s Manual
Power Supply
Amplifier: AC 220-230 V / 50-60 Hz
Transmitter: Adaptor ( I/P: AC 100-240 V / 50-60 Hz
/ 0.45 A,O/P: 18 Vdc / 400 mA )
Transmitter: Adaptor ( I/P: AC 100-240 V / 50-60 Hz
/ 0.45 A,O/P: 18 Vdc / 400 mA )
Connecting I/O Ports
Sub In (R/L/LFE) ﹡1
Transmitter Sub In ﹡1
Transmitter Sub In ﹡1
2.3 Tested Configuration
The EUT connected with other devices.
Following peripheral devices and interface cables were connected during the
measurement: For Conducted Emission Test and Radiated Emission Test
Following peripheral devices and interface cables were connected during the
measurement: For Conducted Emission Test and Radiated Emission Test
Device Manufacturer
Model
Description
Notebook ACER
MS2231
Sound
Generator
TEST CONFIGURATION
EUT
Notebook
Audio
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
4
3. Test Mode & EUT Components Description
To investigate the maximum EMI emission characteristics generates from EUT, the
test system was pre-scanning tested base on the consideration of following EUT
operation mode or test configuration mode which possible have effect on EMI
emission level. Each of these EUT operation mode(s) or test configuration mode(s)
mentioned above was evaluated respectively.
Data of test
2010/02/25
Temperature
23.3 ℃
Location
DTV Shield Room
Humidity
39 %RH
Data of test
2010/02/25
Temperature
15.1 ℃
Location
Fully Anechoic Chamber Humidity
62 %RH
Data of test
2010/02/25
Temperature
21.4 ℃
Location
EFT Room
Humidity
44 %RH
Data of test
2010/02/25
Temperature
22.1 ℃
Location
ESD Room
Humidity
50 %RH
Test Mode
Monitor
Sound
Sound play mode
Speaker PASS