DOWNLOAD JBL ES 150PW (serv.man3) Service Manual ↓ Size: 3.21 MB | Pages: 48 in PDF or view online for FREE

Model
ES 150PW (serv.man3)
Pages
48
Size
3.21 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
es-150pw-sm3.pdf
Date

JBL ES 150PW (serv.man3) EMC - CB Certificate ▷ View online

Report No:W-N-1002010-CY-01-1                                                                                                       
Telecom Technology Center 
 
 
1. TEST REPORT CERTIFICATION 
 
Applicant: Meiloon Industrial Co., Ltd. 
Address: No.77, Lane 1775, Chuen-Ryh Road, Taoyuan City, Taiwan 
 
EUT: Wireless Speaker Amplifier 
Trade Name: JBL 
Model No. : ES150PW/230 
 
Test Standards: EN 55020:2007 
              IEC 61000-4-2:1995+A1:1998+A2:2000 
              IEC 61000-4-3:2006+A1:2007 
              IEC 61000-4-4:2004 
 
 
Report No:W-N-1002010-CY-01-1                                                                                                       
Telecom Technology Center 
 
2. SUMMARY OF TEST RESULTS 
 
2.1 Test Result 
The EUT has been tested according to the following specifications: 
 
IMMUNITY(EN 55020: 2007) 
Standard 
Test Type 
Result
Remarks 
Input immunity 
N/A 
The immunity test at antenna 
input terminal of EUT. 
The performance criteria is A 
Immunity to Induced voltages PASS
The immunity test at Audio 
and mains terminal of EUT by 
CDN. 
The performance criteria is A 
Immunity to RF voltage at 
antenna terminal 
N/A 
The immunity test at antenna 
input terminal of EUT by 
CDN. 
The performance criteria is A 
Immunity from radiated 
fields 
PASS
The immunity test at enclosure 
of EUT by open strip line. 
The performance criteria is A 
EN 55020:2007 
Screening effectiveness 
N/A 
The screening effectiveness is 
50dB 
EN 55020:2007 
IEC 61000-4-2 
Electrostatic discharge 
immunity test 
PASS
Contact discharge up to  ±4 kV
Air discharge up to  ±8 kV 
The performance criteria is B 
EN 55020:2007 
IEC 61000-4-3 
Radiated, radio-frequency, 
electromagnetic field 
immunity test 
PASS
900MHz 
(duty cycle 1/8 , 217Hz 
repetition frequency): 3V/m 
The performance criteria is A 
EN 55020:2007 
IEC 61000-4-4 
Electrical fast transient / burst 
immunity test. 
PASS
±
0.5 kV,  ±1 kV(AC Input) 
The performance criteria is B 
 
The above equipment has been tested by Telecom Technology Center, and found 
compliance with the requirement of the above standards. The test record, data 
evaluation & Equipment Under Test (EUT) configurations represented herein are true 
and accurate accounts of the measurements of the sample’s EMC characteristics under 
the conditions specified in this report. 
Report No:W-N-1002010-CY-01-1                                                                                                       
Telecom Technology Center 
 
2.2 Description of EUT
 
EUT 
Wireless Speaker Amplifier 
Trade Name 
JBL 
Model No. 
ES150PW/230 
Serial No. 
N/A 
Product Description 
More details of EUT Technical specification please 
refer to the User’s Manual 
Power Supply 
Amplifier: AC 220-230 V / 50-60 Hz 
Transmitter: Adaptor ( I/P: AC 100-240 V / 50-60 Hz 
/ 0.45 A,O/P: 18 Vdc / 400 mA ) 
Connecting I/O Ports 
Sub In (R/L/LFE)  ﹡1 
Transmitter Sub In  ﹡1 
 
2.3 Tested Configuration 
The EUT connected with other devices. 
Following peripheral devices and interface cables were connected during the 
measurement: For Conducted Emission Test and Radiated Emission Test
 
 
Device Manufacturer 
Model 
Description 
Notebook ACER 
MS2231 
Sound 
Generator 
 
 
 
TEST CONFIGURATION 
 
 
 
 
 
 
 
 
 
 
 
 
 
EUT
 
Notebook
 
Audio 
Report No:W-N-1002010-CY-01-1                                                                                                       
Telecom Technology Center 
 
3. Test Mode & EUT Components Description 
 
To investigate the maximum EMI emission characteristics generates from EUT, the 
test system was pre-scanning tested base on the consideration of following EUT 
operation mode or test configuration mode which possible have effect on EMI 
emission level. Each of these EUT operation mode(s) or test configuration mode(s) 
mentioned above was evaluated respectively.
 
 
Data of test 
2010/02/25 
Temperature 
23.3  ℃ 
Location 
DTV Shield Room 
Humidity 
39 %RH 
 
Data of test 
2010/02/25 
Temperature 
15.1 ℃ 
Location 
Fully Anechoic Chamber  Humidity 
62 %RH 
 
Data of test 
2010/02/25 
Temperature 
21.4 ℃ 
Location 
EFT Room 
Humidity 
44 %RH 
 
Data of test 
2010/02/25 
Temperature 
22.1 ℃ 
Location 
ESD Room 
Humidity 
50 %RH 
 
 
Test Mode 
Monitor 
Sound 
Sound play mode 
Speaker PASS 
 
 
 
Page of 48