JBL ES 150PW (serv.man3) EMC - CB Certificate ▷ View online
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
29
6.7 ELECTROSTATIC DISCHARGE
6.7.1 Test Specification
Basic Standard:
IEC 61000-4-2
Discharge Impedance:
330 ohm / 150 pF
Discharge Voltage:
Air Discharge:2kV/4kV/8kV (Direct)
Contact Discharge:2kV/4kV (Direct/Indirect)
Contact Discharge:2kV/4kV (Direct/Indirect)
Polarity:
Positive & Negative
Number of Discharge:
Air Discharge: min. 10 times at each test point
Contact Discharge: min. 200 times in total
Contact Discharge: min. 200 times in total
Discharge Mode:
Single Discharge
Discharge Period:
1 second minimum
6.7.2 Test Procedure
The test generator necessary to perform direct and indirect application of discharges
to the EUT in the following manner:
a. Contact discharge was applied to conductive surfaces and coupling planes of the
EUT.
to the EUT in the following manner:
a. Contact discharge was applied to conductive surfaces and coupling planes of the
EUT.
During the test, it was performed with single discharges. For the single discharge
time
between successive single discharges was at least 1 second. The EUT shall be
exposed to at least 200 discharges, 100 each at negative and positive polarity, at a
minimum of four test points. One of the test points shall be subjected to at least 50
indirect discharges to the center of the front edge of the horizontal coupling plane.
The remaining three test points shall each receive at least 50 direct contact
discharges.
If no direct contact test points are available, then at least 200 indirect discharges
shall be applied in the indirect mode. Test shall be performed at a maximum
repetition rate of one discharge per second.
The selected point, which was performed with electrostatic discharge, please
refers to the “Photo(s) shown the location(s) of ESD evaluated”.
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and
positioned at a distance 0.1m from, the EUT, with the Discharge Electrode
touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned
vertically at a distance of 0.1m from the EUT, with the Discharge Electrode
touching the coupling plane. The four faces of the EUT will be performed with
electrostatic discharge.
time
between successive single discharges was at least 1 second. The EUT shall be
exposed to at least 200 discharges, 100 each at negative and positive polarity, at a
minimum of four test points. One of the test points shall be subjected to at least 50
indirect discharges to the center of the front edge of the horizontal coupling plane.
The remaining three test points shall each receive at least 50 direct contact
discharges.
If no direct contact test points are available, then at least 200 indirect discharges
shall be applied in the indirect mode. Test shall be performed at a maximum
repetition rate of one discharge per second.
The selected point, which was performed with electrostatic discharge, please
refers to the “Photo(s) shown the location(s) of ESD evaluated”.
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and
positioned at a distance 0.1m from, the EUT, with the Discharge Electrode
touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned
vertically at a distance of 0.1m from the EUT, with the Discharge Electrode
touching the coupling plane. The four faces of the EUT will be performed with
electrostatic discharge.
b. Air discharges at insulation surfaces of the EUT.
It was at least ten single discharges with positive and negative at the same selected
point.
point.
c. For the actual test configuration, please refer to the related Item –EUT Test Photos.
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
30
6.7.3 Deviation From Test Standard
No deviation
6.7.4 Test Setup
Note:
TABLE-TOP EQUIPMENT
The configuration consisted of a wooden table 0.8 meters high standing on the
Ground Reference Plane. The GRP consisted of a sheet of aluminum at least 0.25mm
thick, and 2.5 meters square connected to the protective grounding system. A
Horizontal Coupling Plane (1.6m x 0.8m) was placed on the table and attached to the
GRP by means of a cable with 940k total impedance. The equipment under test, was
installed in a representative system as described in section 7 of IEC 61000-4-2, and its
cables were placed on the HCP and isolated by an insulating support of 0.5mm
thickness. A distance of1-meter minimum was provided between the EUT and the
walls of the laboratory and any other metallic structure.
FLOOR-STANDING EQUIPMENT
The equipment under test was installed in a representative system as described in
section 7 of IEC 61000-4-2, and its cables were isolated from the Ground Reference
Plane by an insulating support of 0.1-meter thickness. The GRP consisted of a sheet
of aluminum that is at least 0.25mm thick, and 2.5meters square connected to the
protective grounding system and extended at least 0.5 meters from the EUT on all
sides.
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
31
6.7.5 Test Photographs
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
32
Blue arrow mark for Contact Discharge and red arrow mark for Air Discharge
Blue arrow mark for Contact Discharge and red arrow mark for Air Discharge