JBL ENCOUNTER (serv.man6) EMC - CB Certificate ▷ View online

IEC 60950
Clause
Requirement 
 Test
Result - Remark
Verdict
TRF No.:
 I950___D
TRF originator: FIMKO
Page 31 of 74
<E 2060978E01>
6.3.3.1
Insulation between TNV circuit and parts or circuitry
that may be earthed
N
6.3.3.2
Exclusions ...............................................................:
N
6.3.4.1
Limitation of leakage current (mA) to
telecommunication network  ....................................:
N
6.3.4.2
Summation of leakage currents from
telecommunication network  ....................................:
N
6.4
Protection of the equipment user from voltages on the telecommunication network
N
6.4.1
Separation requirements
N
6.4.2
Test procedure
N
6.4.2.1
Impulse test: separation between TNV-1 circuits/TNV-3 circuits and:
N
6.4.2.1 a)
unearthed conductive parts/non-conductive parts of
the equipment expected to be held or touched
during normal use; test at 2,5 kV
N
6.4.2.1 b)
parts and circuitry that can be touched by the test
finger except contacts of connectors that cannot be
touched by test probe; test at 1,5 kV
N
6.4.2.1 c)
circuitry which is provided for connection of other
equipment; test at 1,5 kV
N
6.4.2.2
Electric strength test: separation between TNV-1 circuits/TNV-3 circuits and:
N
6.4.2.2 a)
unearthed conductive parts/non-conductive parts of
the equipment expected to be held or touched
during normal use; test at 1,5 kV
N
6.4.2.2 b)
parts and circuitry that can be touched by the test
finger except contacts of connectors that cannot be
touched by test probe; test at 1,0 kV
N
6.4.2.2 c)
circuitry which is provided for connection of other
equipment; test at 1,0 kV
N
6.4.2.3
Compliance criteria
N
6.5
Protection of telecommunication wiring system from overheating
N
Maximum continuous output current (A)  ................:
N
IEC 60950
Clause
Requirement 
 Test
Result - Remark
Verdict
TRF No.:
 I950___D
TRF originator: FIMKO
Page 32 of 74
<E 2060978E01>
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
P
A.1
Flammability test for fire enclosures of moveable equipment having a total mass
exceeding 18 kg, and of stationary equipment
N
A.2
Flammability test for fire enclosures of moveable equipment having a total mass not
exceeding 18 kg, and for materials located within fire enclosures
P
A.3
High current arcing ignition test
N
A.3.6
Number of arcs  .......................................................:
N
A.4
Hot wire ignition test
N
A.4.6
Ignition time (s) ........................................................:
N
A.5
Hot flaming oil test
N
A.6
Flammability test for classifying materials V-0, V-1
or V-2
N
A.7
Flammability test for classifying foamed materials
HF-1, HF-2 or HBF
N
A.8
Flammability test for classifying materials HB
N
A.9
Flammability test for classifying materials 5V
N
A
Tested material
N
Preconditioning: 7 days (168 h); temperature (
°
C) .:
Mounting of samples during test .............................:
Wall thickness  .........................................................:
Sample 1 burning time ............................................:
N
Sample 2 burning time ............................................:
N
Sample 3 burning time ............................................:
N
Material: compliance with the requirements
N
Manufacturer of tested material ..............................:
Type of tested material  ...........................................:
Additional information ..............................................:
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS
See 5.4.2
N
B.1
General requirements
N
Position ....................................................................:
Manufacturer ...........................................................:
Type .........................................................................:
IEC 60950
Clause
Requirement 
 Test
Result - Remark
Verdict
TRF No.:
 I950___D
TRF originator: FIMKO
Page 33 of 74
<E 2060978E01>
Rated voltage (V) or current (A) ..............................:
B.2
Test conditions
N
B.3
Maximum temperatures
N
B.4
Running overload test
N
B.5
Locked-rotor overload test
N
Test duration (days)  ................................................:
Electric strength test: test voltage (V)  .....................:
B.6
Running overload test for DC motor in secondary
circuits
N
B.7
Locked-rotor overload test for DC motor in secondary circuits
N
B.7.2
Test time (h)  ............................................................:
N
B.7.3
Test time (h)  ............................................................:
N
B.8
Test for motors with capacitors
N
B.9
Test for three-phase motors
N
B.10
Test for series motors
N
Test voltage (V) .......................................................:
C
ANNEX C, TRANSFORMERS
P
Position ....................................................................: P.T.
Manufacturer ...........................................................: Full Technics Electronic Ltd
Type .........................................................................: TEAC-48-XYZ, TEAD-48-XYZ,
TEAC-XYZ, TE-XYZ series
Rated values  ...........................................................: class B
Temperatures
(see appended table 5.4)
P
Thermal cut-out
(see appended table 5.1)
P
C.1
Overload test
(see 5.4.3)
P
Conventional transformer
N
C.2
Insulation
P
Precautions .............................................................: (see transformer construction
check next page)
P
Retaining of end turns of all windings
Ditto
P
Earthing test at 25 A
Ditto
N
C.3
Electric strength test
(see 5.3)
P
IEC 60950
Clause
Requirement 
 Test
Result - Remark
Verdict
TRF No.:
 I950___D
TRF originator: FIMKO
Page 34 of 74
<E 2060978E01>
C.2
Safety isolation transformer
P
Construction details:
Transformer P.T.
Mfr.: Full Technics Electronic Ltd
Type : TEAC-48-XYV, TEAD-48-XYV, TEAC-XYV, TE-XYV
series
Recurring peak voltage
326V 0-p
Required clearance for reinforced
insulation (from table 3 and 4)
4.0mm + 0.0mm
Effective voltage rms
230V
Required creepage for reinforced
insulation (from table 6)
5.0mm
Measured min. creepages
Location
inside (mm)
outside (mm)
prim-sec
7.1
>7.1
prim-core
6.1
>6.1
sec-core
1.0
>1.0
prim-prim
%
%
Measured min. clearances
Location
inside (mm)
outside (mm)
prim-sec
7.1
>7.1
prim-core
6.1
>6.1
sec-core
1.0
>1.0
prim-prim
%
%
Construction:
Primary and secondary wires wound on separated Nylon 66 bobbin. Outer wraps for primary and secondary
windings are three-layer Mylar film insulation. Core is made by silicone steel (type EI-48). Windings held in
position by tape and spool design of bobbin. Winding ends fixed with tape. Thermal fuse was wrap inside the
primary windings and held in position by tape.