DATE
DOCUMENT NAME
DOCUMENT #
PAGE
September 17, 2004
Harman Multimedia JBL Encounter EMC Test Report
2004 090584 EMC
29 of 79
Figure 6. EFT Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1. Test Laboratory (6 x 7 meters)
2. Ground
Plane
3. Power Strip for Peripherals from power line filter
4. DC Power for Devices
5. Capacitive Coupling Clamp (grounded)
6. Mains Power for EUT
7. AC Power for Fast Transient Noise Generator (120V)
8. Fast Transient Noise Generator
9. Coupling
4. DC Power for Devices
5. Capacitive Coupling Clamp (grounded)
6. Mains Power for EUT
7. AC Power for Fast Transient Noise Generator (120V)
8. Fast Transient Noise Generator
9. Coupling
Network
10. 10cm Non-Conducting Platform
11. EUT
12. Associated System
11. EUT
12. Associated System
1
10
2
3
4
9
8
6
7
5
11
10
12
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
September 17, 2004
Harman Multimedia JBL Encounter EMC Test Report
2004 090584 EMC
30 of 79
4.10. Power Line Surge Immunity: IEC 61000-4-5 (1995),A1(2001)
This test simulates a lightning event by inducing transients onto the AC/DC power supply lines in common
and differential mode. Testing was performed in accordance with IEC 61000-4-5.
Each device was tested in a total of three surge configurations:
Surge #1: Combination Wave, Line to Protective Earth with 9uF and 10Ohm, common mode, generator
earthed.
Surge #2: Combination Wave, Neutral to Protective Earth with 9uF and 10Ohm, common mode,
generator earthed.
Surge #3: Combination Wave, Line to Neutral with 18uF, differential mode, generator floated.
For further information, please refer to the technical sections in the IEC 61000-4-5 in addition to the test
results section and photographs of the test set-up provided in this report.
For further information, please refer to the technical sections in the IEC 61000-4-5 in addition to the test
results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
September 17, 2004
Harman Multimedia JBL Encounter EMC Test Report
2004 090584 EMC
31 of 79
Figure 7. Power Line Surge Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1. Test
Laboratory
2. AC power for Devices
3. Power strip for associated devices from power line filter
4. Copper Ground Plane
5. Surge
3. Power strip for associated devices from power line filter
4. Copper Ground Plane
5. Surge
Generator
6. Surge Coupling Network
7. Nonconductive tables 80cm above Ground Plane
8. EUT
7. Nonconductive tables 80cm above Ground Plane
8. EUT
9. Associated
System
3
2
4
7
1
6
5
7
8
9
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
September 17, 2004
Harman Multimedia JBL Encounter EMC Test Report
2004 090584 EMC
32 of 79
4.11. Radio Frequency Conducted Common Mode Immunity: IEC 61000-4-6
(1996)A1(2000)
This test injects a disturbance directly onto AC/DC power and signal I/O cables. Testing was performed in
accordance with IEC 61000-4-6. The standard configuration as outlined in the IEC 61000-4-6 was used. For
further information, please refer to the technical sections of the IEC 61000-4-6 publication in addition to the
test results section and photographs of the test set-up provided in this report.