DOWNLOAD JBL DUET II (serv.man7) Service Manual ↓ Size: 1007.3 KB | Pages: 87 in PDF or view online for FREE

Model
DUET II (serv.man7)
Pages
87
Size
1007.3 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
duet-ii-sm7.pdf
Date

JBL DUET II (serv.man7) EMC - CB Certificate ▷ View online

 
 
- Page 49 of 51 - 
 
 
www.nemko.com
 
Report No.  114383 
 
TRF No.:IECEN60950_1B 
 
 
4.7 
TABLE: resistance to fire 
N/A 
 
part 
manufacturer of material 
type of material 
thickness 
(mm) 
flammability
class 
 
 
 
 
 
supplementary information: 
 
 
5.1 
TABLE: touch current measurement 
N/A 
 
Measured between: 
Measured  
(mA) 
Limit  
(mA) 
Comments/conditions 
Class III equipment. 
 
 
 
 
 
 
 
supplementary information: 
 
 
5.2 
TABLE: electric strength tests, impulse tests and voltage surge tests 
N/A 
 
test voltage applied between: 
test voltage (V) 
a.c. / d.c. 
breakdown 
 Yes / No 
Class III equipment. 
 
 
 
 
 
supplementary information 
 
 
 
 
- Page 50 of 51 - 
 
 
www.nemko.com
 
Report No.  114383 
 
TRF No.:IECEN60950_1B 
 
 
5.3 
TABLE: Fault condition tests 
 
Ambient temperature (
°C) ...................................:  25°C 
⎯ 
 
Power source for EUT: Manufacturer, model/type, 
output rating .........................................................: 
Refer to page 41 
⎯ 
Component  
No. 
Fault 
Supply  
voltage 
 (V) 
Test time
Fuse # 
Fuse  
current  
(A) 
Observation 
U6 pin 2-8 
s-c 
264 
3h8min
F1 
(inside 
adapter)
0.961 
Unit operated normally, no 
hazards, no damaged. Max. 
measured temp. in  
PCB near U6= 116.3°C,  
Enclosure=40.7°C,  
ambient= 27°C 
U6 pin 8-9 
s-c 
264 
10min 
F1 
(inside 
adapter)
0.004 
Unit shutdown, no hazards. 
U6 pin 2-9 
s-c 
264 
7h3min
F1 
(inside 
adapter)
1.07 
Unit operated normally, no 
hazards, no damaged. Max. 
measured temp. in  
PCB near U6= 117.7°C,  
Enclosure=39.8°C,  
ambient= 25.2°C 
C51 s-c 
264 
4.0h 
F1 
(inside 
adapter)
1.13 
Unit operated normally, no 
hazards, no damaged. Max. 
measured temp. in  
PCB near U6= 116.5°C,  
Enclosure=42.3°C,  
ambient= 28.8°C 
C20 s-c 
264 
10min 
F1 
(inside 
adapter)
0.037-0.087 Unit oscillate, no hazards. 
U6 pin 1-9 
s-c 
264 
2h40min
F1 
(inside 
adapter)
0.968 
Unit operated normally, no 
hazards, no damaged. Max. 
measured temp. in  
PCB near U6= 109.9°C,  
Enclosure=41.7°C,  
ambient= 26.3°C 
Speaker 
output  
s-c 264 
8h5min
F1 
(inside 
adapter)
0.273 
Unit operated normally,  
no hazards, no damaged. Max. 
measured temp. in  
PCB= 120.3°C,  
Enclosure=42.8°C,   
ambient= 26.8°C
 
supplementary information: 
S-c = short circuit  
 
 
- Page 51 of 51 - 
 
 
www.nemko.com
 
Report No.  114383 
 
TRF No.:IECEN60950_1B 
 
 
 
C.2 TABLE: 
transformers 
N/A 
 
Loc. 
Tested insulation 
Working 
voltage 
peak / V 
 
(2.10.2) 
Working 
voltage 
rms / V 
 
(2.10.2) 
Required 
electric 
strength 
 
(5.2) 
Required 
clearance / 
mm 
 
(2.10.3) 
Required 
creepage 
distance / 
mm 
(2.10.4) 
Required 
distance 
thr. insul. 
 
(2.10.5) 
 
 
 
 
 
 
 
 
Loc. 
 
 
 
 
Tested insulation 
 
 
Test 
voltage/ 
Measured 
clearance / 
mm 
Measured 
creepage 
dist./ mm 
Measured 
distance 
thr. insul. / 
mm; 
number of 
layers 
 
 
 
 
 
 
supplementary information: 
 
 
 
 
- Page 1 of 6 - 
 
photos
 
www.nemko.com 
Report No.  114383 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 87
Display