JBL DSC 1000 EMC - CB Certificate ▷ View online
Page 8 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
< 5V
P
If C is not greater than 0,1 µF no test needed
0.2
µ
F
N
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
P
30 mm diameter test tool for 5 s (100 or 250 N) ... : 100N
P
9.2
No hazard after removing a cover by hand
Can not be removed by hand
N
10
INSULATION REQUIREMENTS
10.1
Insulation resistance (MO) at least 2 MO min. after
surge test for basic and 4 MO min. for reinforced
insulation ......................................................... :
surge test for basic and 4 MO min. for reinforced
insulation ......................................................... :
(See appended table)
P
10.2
Humidity treatment 48 h or 120 h ....................... : 120h, 40
O
C, 93%R.H.
P
10.3
Insulation resistance and dielectric strength
(See appended table)
P
11
FAULT CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
(See appended table)
P
No hazard from softening solder
P
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N
Page 9 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
P
12
MECHANICAL STRENGTH
12.1.1
Bump test where mass >7 kg
4.6kg
N
12.1.2
Vibration test
Not carried out, no connection
which might impair safety can
become loosen
which might impair safety can
become loosen
P
12.1.3
Impact hammer test
0.5J
P
Steel ball test
2J
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
P
12.1.5
Thermoplastic enclosures strain relief test
70
o
C, 7h
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
P
12.5
Antenna coaxial sockets providing isolation
N
12.6
Telescoping or rod antennas construction
N
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Between TR1 primary winding
and secondary winding
minimum 4.2mm required.
(458V peak)
and secondary winding
minimum 4.2mm required.
(458V peak)
Between TR2 primary winding
and secondary winding
minimum 4.3mm required.
(504V peak)
and secondary winding
minimum 4.3mm required.
(504V peak)
P
Page 10 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Creepage distances in accordance with 13.4
Between TR1 primary winding
and secondary winding in
transformer 5.6mm required.
(400V r.m.s., margin tape and
insulating tape material group
II )
and secondary winding in
transformer 5.6mm required.
(400V r.m.s., margin tape and
insulating tape material group
II )
Between TR2 primary winding
and secondary winding in
transformer 5.6mm required.
(392V r.m.s., margin tape and
insulating tape material group
II )
and secondary winding in
transformer 5.6mm required.
(392V r.m.s., margin tape and
insulating tape material group
II )
Between TR1 primary winding
leader and secondary on PCB
track 5.6mm required (400V
r.m.s., PCB material group II).
leader and secondary on PCB
track 5.6mm required (400V
r.m.s., PCB material group II).
Between TR2 primary winding
leader and secondary on PCB
track 5.6mm required (392V
r.m.s., PCB material group II).
leader and secondary on PCB
track 5.6mm required (392V
r.m.s., PCB material group II).
Other PCB tracks between
primary and secondary 4.0mm
required (264V r.m.s., PCB
material group II).
primary and secondary 4.0mm
required (264V r.m.s., PCB
material group II).
P
13.2
Determination of operating voltage
P
13.3
Clearances
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
Between primary and
secondary: minimum 6.0 mm
on PCB track
secondary: minimum 6.0 mm
on PCB track
Different polarity conductively
connected to the mains:
minimum 3.5mm on PCB track
connected to the mains:
minimum 3.5mm on PCB track
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N
13.4
Creepage distances
Between primary and
secondary on PCB track
minimum 6.0mm.
secondary on PCB track
minimum 6.0mm.
P
Creepage distances greater than table 11 minima
P
13.5
Printed boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
Page 11 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
No such parts
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No such parts
N
14
COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistor
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N
b) Resistors separately approved ....................... : No
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY1, CY2, CY3, CY4,
CY5, CY6
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: CX1, CX2
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ................... :
connected to the mains: tests for X2 ................... :
No such component
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better .............................................................. :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better .............................................................. :
EC16 metal case
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ................................... :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ................................... :
EC16 metal case
N
Shielded by a barrier to V-0 or metal .................. :
N
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N
Click on the first or last page to see other DSC 1000 service manuals if exist.