JBL DSC 1000 EMC - CB Certificate ▷ View online
Page 32 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Annex
ZC
ZC
(informative)
A-deviations
A-deviation: A national deviation due to regulations, the alteration of which - at least for
the time being - outside the competence of the CEN/CENELEC member.
the time being - outside the competence of the CEN/CENELEC member.
5
Germany
The following markings are required:
a) In case of intrinsically ionizing radiation safe
cathode-ray tubes with accelerating voltages
between 20 kV and 30 kV:
- On the cathode-ray tube itself the wording:
Eigensichere Kathodenstrahlröhre nach Anlage
III Röntgen-verordnung
- Inside the apparatus:
the maximum allowed accelerating voltage in kV,
and the maximum allowed beam current in mA.
- On the outer of the apparatus:
a notice in German language that produced X-
rays are sufficiently shielded by the intrinsically
safe cathode-ray tube.
b) In case of approval of the whole TV receiver
with an accelerating voltage
exceeding 20 kV:
- On the outer of the apparatus:
the licence number .../.../.../Rö, and the following
text:
Die in diesem Gerät entstehende
Röntgenstrahlung ist ausreichend
abgeschirmt. Beschleunigungsspannung: max: ...
kV.
- Supplied with the apparatus:
a copy of the "Zulassungsschein", together with
the notices required there.
c) In case of TV receivers with accelerating
voltages not exceeding 20 kV:
Die in diesem Gerät entstehende
Röntgenstrahlung ist ausreichend
abgeschirmt. Beschleunigungsspannung: max: ...
kV.
Justification:
German ministerial decree against ionizing
radiation ( Röntgenverordnung),
dated 1987-01-08.
The following markings are required:
a) In case of intrinsically ionizing radiation safe
cathode-ray tubes with accelerating voltages
between 20 kV and 30 kV:
- On the cathode-ray tube itself the wording:
Eigensichere Kathodenstrahlröhre nach Anlage
III Röntgen-verordnung
- Inside the apparatus:
the maximum allowed accelerating voltage in kV,
and the maximum allowed beam current in mA.
- On the outer of the apparatus:
a notice in German language that produced X-
rays are sufficiently shielded by the intrinsically
safe cathode-ray tube.
b) In case of approval of the whole TV receiver
with an accelerating voltage
exceeding 20 kV:
- On the outer of the apparatus:
the licence number .../.../.../Rö, and the following
text:
Die in diesem Gerät entstehende
Röntgenstrahlung ist ausreichend
abgeschirmt. Beschleunigungsspannung: max: ...
kV.
- Supplied with the apparatus:
a copy of the "Zulassungsschein", together with
the notices required there.
c) In case of TV receivers with accelerating
voltages not exceeding 20 kV:
Die in diesem Gerät entstehende
Röntgenstrahlung ist ausreichend
abgeschirmt. Beschleunigungsspannung: max: ...
kV.
Justification:
German ministerial decree against ionizing
radiation ( Röntgenverordnung),
dated 1987-01-08.
NOTE The German ministerial decree (Röntgenverordnung)
is under revision.
N
Page 33 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
5.1
Italy
The following requirements shall be fulfilled:
- The power consumption in Watts (W) shall be
indicated on TV receivers and in their instruction
for use (Measurement according to EN 60555-2)
The following requirements shall be fulfilled:
- The power consumption in Watts (W) shall be
indicated on TV receivers and in their instruction
for use (Measurement according to EN 60555-2)
NOTE EN 60555-2 has since been replaced by IEC 60107-
1:1997.
1:1997.
- TV receivers shall be provided with an
instruction for use, schematic diagrams
and adjustments procedure in Italian language.
- Marking for controls and terminals shall be in
Italian language. Abbreviation and international
symbols are allowed provided that they are
explained in the instruction for use.
- The ECC manufacturers are bound to issue a
conformity declaration according to the above
requirements in the instruction manual. The
correct statement for conformity to be written in
the instruction manual, shall be:
Questo apparecchio è fabbricato nella CEE nel
rispetto delle disposizioni del D.M. marzo 1992
ed è in particolare conforme alle prescrizioni
dell'art.
1 dello stesso D.M.
- The first importers of TV receivers
manufactured outside EEC are bound to submit
the TV receivers for previous conformity
certification to the Italian Post Ministry (PP.TT).
The TV receivers shall have on the backcover the
certification number in the following form:
D.M. 26/03/1992 xxxxx/xxxxx/S or T or pT
S for stereo
T for teletext
pT for retrofitable teletext
Justification:
Ministerial Decree of 26 March 1992: National
rules for television receivers
trade.
instruction for use, schematic diagrams
and adjustments procedure in Italian language.
- Marking for controls and terminals shall be in
Italian language. Abbreviation and international
symbols are allowed provided that they are
explained in the instruction for use.
- The ECC manufacturers are bound to issue a
conformity declaration according to the above
requirements in the instruction manual. The
correct statement for conformity to be written in
the instruction manual, shall be:
Questo apparecchio è fabbricato nella CEE nel
rispetto delle disposizioni del D.M. marzo 1992
ed è in particolare conforme alle prescrizioni
dell'art.
1 dello stesso D.M.
- The first importers of TV receivers
manufactured outside EEC are bound to submit
the TV receivers for previous conformity
certification to the Italian Post Ministry (PP.TT).
The TV receivers shall have on the backcover the
certification number in the following form:
D.M. 26/03/1992 xxxxx/xxxxx/S or T or pT
S for stereo
T for teletext
pT for retrofitable teletext
Justification:
Ministerial Decree of 26 March 1992: National
rules for television receivers
trade.
NOTE The ministerial decree above contains additional, but
not safety relevant requirements.
N
14
Sweden
The following is added:
Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification:
Ordinance (1990:944) on Prohibition in cnnection
with Handling, Importation and Exportation of
Chemical Products (Certain Cases)
The following is added:
Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification:
Ordinance (1990:944) on Prohibition in cnnection
with Handling, Importation and Exportation of
Chemical Products (Certain Cases)
Only approved MOMS is
provided.
provided.
P
Page 34 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
OFF: 0
Stand-by: <1.3W
P
Position of the functional switch (W) ....................: --
—
Operating conditions
25
o
C, normal DVD playing, operates for 4h until steady condition reached.
Un (V)
In (A)
Pn (W)
Pout (W)
100 x 0.9 = 90
0.633
36.9
N.A.
240 x 1.1 = 264
0.249
37.8
N.A.
Loudspeaker impedance (O) ..............................: 4 O X 5
—
Several loudspeaker systems
5 channel speakers
P
Marking of loudspeaker terminals
Printed on rear enclosure
P
Monitored point:
dT (K) 90V / 264V
Limit dT (K)
Enclosure (metal)
9.8 / 13.3
40
Enclosure (plastic)
8.0 / 12.5
60
Fuse holder
20.2 / 18.2
60
Live wire insulation near heat sink inside enclosure
16.5 / 22.0
60
Mains wire insulation outside enclosure
5.7 / 6.2
60
Mating lock connector
19.1 / 18.7
-
PCB (near primary heat sink)
24.1 / 30.3
95
Transformer winding (TR1)
41.5 / 50.4
75*
Bobbin of TR1
46. / 55.6
125 (T150)
Transformer winding (TR2)
42.6 / 48.7
75*
Bobbin of TR1
44.9 / 50.9
125 (T150)
Line filter winding (LF2)
34.1 / 16.0
75*
Y capacitor
14.5 / 13.2
60 (T85)
X capacitor
19.0 / 16.4
60 (T85)
Power switch
7.1 / 7.6
60 (T85)
Electrolytic capacitor (EC16)
15.3 / 14.9
80 (T105)
Electrolytic capacitor (AC62)
17.1 / 18.7
80 (T105)
Winding temperature rise measurements
N
Ambient temperature t1 (
o
C) ...............................:
—
Page 35 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Ambient temperature t2 (
o
C) ...............................:
—
Temperature rise dT of winding:
R
1
(O)
R
2
(O)
dT (K)
Limit dT
(K)
Insulation
class
* The limit value reduced by 10K due to the thermal coupler method used.
7.2
TABLE: softening temperature of thermoplastics
N
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MO)
Required R (MO)
Between mains poles (primary fuse disconnected)
>100
2
Between parts separated by basic or supplementary insulation
>100
2
Between parts separated by double or reinforced insulation
>100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120
No
Between parts separated by basic or supplementary insulation
2120
No
Between parts separated by double or reinforced insulation
4240
No
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ........... : 100-240
—
Ambient temperature (
o
C) .................................. : 25
—
Monitored point: TR1 insulation tape between primary and secondary.
Under fault conditions specified below
dT (K)
Limit dT (K)
One diode short circuit, fuse FU1 opened immediately.
-
-
EC16 short circuit, fuse FU1 opened immediately.
-
-
PH2 pin 1-2 short circuit, power consumption 26 - 38W, no extreme high
temperature, no hazard.
temperature, no hazard.
57
105 (T130)
PH2 pin 3-4 short circuit, as normal, no hazard.
51
105 (T130)