JBL DSC 1000 EMC - CB Certificate ▷ View online
Page 40 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Insulation Sheet
GE PLASTICS
CHINA LTD
PC
Thickness:
0.51mm
FV0, 130℃
IEC 60065
UL(E205960)
and tested with
appliance
Varistor
GUANGDONG
FOSHAN
KESTAR
ELECTRONIC
CO LTD
FOSHAN
KESTAR
ELECTRONIC
CO LTD
MYG10K471
470V
IEC 61051-2
UL(E191293)
and tested with
appliance
and tested with
appliance
Page 41 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
National differences for CHINA
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1993 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1993 and adopted to IEC 60065:2001.)
IEC 60065 sub-clause 4.2.2: Test voltage is 0.9
times or 1.06 times rated voltage of the
equipment; GB8898 sub-clause 4.2.2: Test
voltage is 0.9 times or 1.1 times rated voltage of
the equipment, which of the equipment used in
China shall cover 220V ±10%, 50Hz.
times or 1.06 times rated voltage of the
equipment; GB8898 sub-clause 4.2.2: Test
voltage is 0.9 times or 1.1 times rated voltage of
the equipment, which of the equipment used in
China shall cover 220V ±10%, 50Hz.
P
IEC standard for plug is IEC 60083; The Chinese
national standard for Plugs is GB1002-1996,
which is not equivalent with IEC 60083
national standard for Plugs is GB1002-1996,
which is not equivalent with IEC 60083
P
Page 42 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
National differences for KOREA
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
5.101
Other marking ; Wording "____ “ or an
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
N
15.1.1
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
P
31
Radio frequency interference
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
Not
checked
Page 43 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
National differences for SINGAPORE
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1993 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 107A. These differences are taken from
IEC60065:1993 and adopted to IEC 60065:2001.)
Throughout the standard, whenever the words "white pine board" appear, insert
the words "or plywood board" to it.
the words "or plywood board" to it.
Noted
SS 143 Amendment No.1 and No. 2
4.1.3
Delete "45 % to 75 %" and insert "65 _ 5 %".
75% maximum in IEC
60065:2001
60065:2001
Noted
7.1
Resistance to heat without external forces
Adopt the temperature specified for the tropical
conditions.
Adopt the temperature specified for the tropical
conditions.
P
8.6
(9.3.4)*
Delete the note "A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
This is not in IEC 60065:2001.
Noted
10.2
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
Adopt the testing conditions designed for tropical
conditions.
120h at a relative humidity of
93%, ambient temperature
40
93%, ambient temperature
40
o
C
P
16
External flexible cords
Delete "IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V" and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords" whenever they
appear in this clause.
Delete "IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V" and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords" whenever they
appear in this clause.
Noted
16.2
Delete the notes in small print and insert "A
nominal cross-sectional area of 0.75 mm
nominal cross-sectional area of 0.75 mm
2
will
satisfy this requirement".
Noted
16.3b
(16.4b)*
Delete "Subclause 3.1 of IEC Publication 227-2:
Part 2: Test Methods" and insert "Subclause 9.1
of SS 236":
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Screene cords in accordance with Table 7 shall
Part 2: Test Methods" and insert "Subclause 9.1
of SS 236":
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
as given in Table 1.
Screene cords in accordance with Table 7 shall
Noted