JBL DSC 1000 EMC - CB Certificate ▷ View online
Page 44 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
be tested before application of the screen and
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
shall be loaded with the current specified in Table
2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
After the test, any sheath on cords having three
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage test
specified in Subclause 8.2. or 8.3 as appropriate,
but with a test voltage not exceeding 2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB bulletin.
outer sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The
restraining clamps D shall be fixed so that the pull
is always applied by the weight from which the
carrier is mowing away. The carrier shall make 30
000 backward and forward movements (60 000
single strokes). Each conductor of the sample
shall be loaded with the current specified in Table
2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
After the test, any sheath on cords having three
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage test
specified in Subclause 8.2. or 8.3 as appropriate,
but with a test voltage not exceeding 2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB bulletin.
*In parenthesis: clauses according to IEC60065:1993.
Page 45 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
National differences MALAYSIA, according to CB bulletin No. 107A
IEC 60065, 7th ed.
IEC 60065, 7th ed.
The supply voltage in Malaysia is 240 Vac, at
50Hz.
50Hz.
P
Class 0 and 01 appliances are not allowed
P
13A fused plug-tops shall comply to Malaysian
standard (MS 589:Part1:1997), if applicable.
standard (MS 589:Part1:1997), if applicable.
Same as BS1363 type.
P
2-pin plug tops shall comply to Malaysian
standard (MS 1578:2003) if applicable
standard (MS 1578:2003) if applicable
N
Page 46 of 53
Report No: JSH0406745-001.
Remarks
External views of EUT
Page 47 of 53
Report No: JSH0406745-001.
Remarks