Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
3
GENERAL REQUIREMENTS
Safety class of the apparatus ............................. : Class II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
Yes
Noted
5
MARKING
Comprehensible and easily discernible
Printed on the rear enclosure
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1
Identification, maker, model ............................... : JBL, DSC 1000
P
Class II symbol if applicable
P
Rated supply voltage and symbol ....................... : 100-240V ~
P
Frequency if safety dependant
50/60Hz
P
Rated current or power consumption .................. : 380W
P
5.2
Earth terminal
Class II
N
Hazardous live terminals
N
Supply output terminals (other than mains)
N
5.3
Use of triangle with exclamation mark
On PCB
P
5.4
Instructions for use
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
P
Hazardous live terminals, instructions for wiring
No such terminals
N
Instructions for replacing lithium battery
No lithium battery
N
Instructions for modem if fitted
No modem fitted
N
Class I earth connection warning
N
Instructions for multimedia system connection
P
Special stability warning for fixed installation
N
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
P
Instructions for permanently connected equipment
N
6
HAZARDOUS RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N
6.2
Laser radiation, emission limits to IEC 60825-1 ... : Class I
P
Page 5 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Emission limits under fault conditions ................. : Class I
P
7
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table)
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No supportive function.
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB, windings
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
P
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Tools are required
P
8.5
Class I equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
P
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
TR1, TR2
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N
Page 6 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
CY1, CY2, CY3, CY4, CY5,
CY6
CY6
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
N
Separation by Class II isolating transformer
N
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced insulation > 0,4 mm (mm) ................. : TR1, TR2 bobbin: 0.8mm
Optocoupler PH1, PH2:
0.45mm
0.45mm
Separation sheet on internal
enclosure under power board:
0.5mm.
enclosure under power board:
0.5mm.
P
Thin sheet insulation
Inside TR1, TR2
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Withstand 4240Vp test.
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Live wires are double
insulated, no secondary wire
can come closer to live parts
insulated, no secondary wire
can come closer to live parts
P
8.11
Detaching of wires
Page 7 of 53
Report No: JSH0406745-001.
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Mating lock connector used for
mains. No risk of detached.
mains. No risk of detached.
N
Vibration test carried out ................................... : No, see above
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
P
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
Not used as a disconnect
device
device
N
8.19.2
Mains switch ON indication
Not used as a disconnect
device
device
N
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
N
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such high voltage
N
9.1.1.1
Touch current measured from terminal devices
using the network in annex D ............................. :
using the network in annex D ............................. :
U1<8.0Vp (a.c.)
U2<0.06Vp (a.c.)
U2<0.06Vp (a.c.)
P
Discharge not exceeding 45 µC
P
Energy of discharge not exceeding 350 m J
No voltage exceeding 15kV
N
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
< 2 mm, no entering
N