Document
EMC - CB Certificate
Brand
Device
Audio
File
cs680-sm2.pdf
Date

JBL CS680 (serv.man2) EMC - CB Certificate ▷ View online

 
Page 25 of 47 
Report Ref No.: 614380 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
11.2 TABLE: 
summary 
of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage ........ : 
220-230 
— 
 Frequency 
(Hz)................................................... : 
50-60 
— 
 Ambient 
temperature 
(
o
C) ................................. :  25 
— 
No 
Component 
Fault 
Temp Rise/ 
Component 
Other results 
(include description and test duration) 
1 Apparatus 
Pmax 
65K/prim.winding 
63K/sec.winding 
56K/core 
53K/PCB 
42/heat sink on rear 
panel 
33K/rear metal encl.
Un=253V, Pn= 138W, In= 0.70A. max Uout= 22V 
Test time= 4h. 
No high temperatures, no remarks. 
Q105 
sc -- 
Un=198V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
3 Q107 sc 
-- 
Un=198V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
4 C133 sc 
-- 
Un=198V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
5 C122 sc 
-- 
Un=253V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
6 C122 sc 
-- 
Un=198V. Pn=450→260W, In=2.3→1.5A 
Printed conductors on the PCB were interrupted. 
When the conductors were bridged the thermal 
link in the transformer opened after 3.5 min. No 
high temperatures, no remarks. 
6 D115 
(  - +) 
sc 
-- 
Un=198V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
D110 
(  - +) 
sc -- 
Un=198V. Mains fuse blew immediately. 
No high temperatures, no remarks. 
C117 
sc -- 
Un=198V. P
mains
 decreased to 8W. Test 
time:12min. No high temperatures, no remarks. 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C) .............. 23 
— 
 
Ambient temperature t2 (
o
C) .............. 25 
— 
 
Page 26 of 47 
Report Ref No.: 614380 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage:  220-230 V 
Pollution degree: 
II 
Material Group: 
IIIb 
2 N force on internal parts applied: 
30 N force on outside of conductive enclosure applied: 
 
 
Location 
 
Operating Voltage 
 
Clearance (mm) 
 
Creepage (mm) 
 
 
V rms 
 
V peak 
 
Min 
 
Actual 
 
Min 
 
Actual 
 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
 
Primary (ac) to Earth (B) 
 
 
 
 
 
 
 
Primary (+dc) to Earth max (B) 
 
 
 
 
 
 
 
Primary (-dc) to Earth max (B) 
 
 
 
 
 
 
 
Across mains fuse (B) 
 
230 
 
345 
 
2.0 
 
8.2 
 
2.3 
 
8.2 
Across primary directly connected to 
the mains (B) 
 
230 
 
345 
 
2.0 
 
7.0 
 
2.3 
 
7.0 
 
Hazardous live secondary to Earth (B)
 
 
 
 
 
 
Optocoupler input to output (R) 
 
 
 
 
 
 
Primary to Secondary red  in 
transformer (R) 
 
295 
 
417 
 
4.0 
 
>10 
 
6.3 
 
8.1 
Primary to Secondary yellow (R) 
 
260 
 
368 
 
4.0 
 
>10 
 
5.3 
 
>8.1 
Primary to accessible conductive 
parts (R) 
 
230 
 
345 
 
4.0 
 
>10 
 
4.6 
 
7.0 
Hazardous live secondary to non-
hazardous live secondary (R) 
 
 
 
 
 
 
Hazardous live secondary to 
unearthed conductive enclosure (R) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed 
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the 
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an 
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth 
via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from 
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 
or 10 as required, then the value for clearance is used as the minimum creepage distance . 
 
"Min" = minimum required.
 
"Actual = Actual dimensions measured. 
 
 
Page 27 of 47 
Report Ref No.: 614380 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Mains Transformer 
Transtec 
TT0869803320
AC 230V, 50Hz 
IEC 60065 
— 
Thermal link 
Joint Force 
M33 
2A, 250V, 130
°C
IEC 60691 
TÜV 
 
Alt. Mains Transformer 
Transtec 
TT0869803320-E
AC 230V, 50Hz 
IEC 60065 
— 
Alt. Thermal link 
Joint Force 
L33 
2A, 250V, 130
°C
IEC 60691 
TÜV 
 
Bobbins Transformer 
EI Dupont de 
Nemours 
Nylon 66  
101, 101F 
Min. HB75 
Complies with 
IEC 60707
 
HB75 
— 
Mains Fuse 
Walter 
TSD 
T1.25AL 250V 
IEC 60127 
 
Appliance inlet 
CHILY 3528 10A 
250V 
FV 0 
IEC 60320-1 
 
Mains switch 
CHILY 
3024 
16(4) 8/128A, 
250V Class II 
IEC 61058-1 
IEC60065:2001
Sub-clause 
14.6 1a) 
FI 
X-Capacitor (across 
the mains switch)
 
Europtronic 
(Taiwan) Ind. 
Corp. 
MPX-X2 0,10µF, 
250V 
 
X2 
IEC 60384-14 
2
nd
 ed. 
 
Sec. Connector P103 
JWT 
A3963Wv2-5P 
V-1 
Complies with 
IEC 60707
 
HB75 
— 
PCB 
Jian He 
(Cheng Ho) 
Various V-1 
Complies with 
IEC 60707      
HB75 
— 
Mains cordset: 
Plug 
Well Shin 
 
WS-019 
 
10-16A   250V 
Connector 
 WS-002E 
10A 
 
250V 
Cord 
 
H05VV-F 
2 x 0.75mm² 
IEC 60799 
 
 
Plastic tub (internal 
enclosure)  
Chi Mei 
ABS Polylac 
PA-765B 
1.5mm/94V-2 
smallest 
thickness used: 
2mm 
Complies with 
IEC 60707     
HB75 
— 
Shrink tubing, 
covering mains switch 
and inlet  
Dongguan 
Quantai 
T-2 VW-1 
Complies with 
IEC 60707     
HB75 
— 
 
 
Page 28 of 47 
Report Ref No.: 614380 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
Group differences  
IEC 60065:2001          
                                                                
CB Bulletin 110A / GRP 06  I
 
 
Contents 
Add the following annexes: 
Annex ZB (nominative) Special national conditions 
Annex ZC (informative) A-deviations  
3.1 
Add the following indent at the end of the list 
Exposure to excessive sound pressures 
from headphones or earphones 
NOTE  A new method of measurement is described in 
EN 50332-1, Sound system equipment: Headphones 
and earphones associated 
with portable audio equipment – Maximum sound 
pressure level measurement methodology and limit 
considerations – Part 1: General 
method for ”one package equipment”, and in EN 
50332-2, Sound system equipment: Headphones and 
earphones associated with 
portable audio equipment – Maximum sound pressure 
level measurement methodology and limit 
considerations – Part 2: Guidelines to 
associate sets with headphones coming from different 
manufacturers. 
 N/A 
4.1.1 
Replace 
the text of the note by: 
NOTE For ROUTINE TEST reference is made to EN 
50333
 P 
5.1.i) 
Add 
the following note: 
NOTE For RATED POWER CONSUMPTION 
mesurements of TVs reference is made to EN 60107. 
 N/A 
Page of 59
Display