JBL CS680 (serv.man2) EMC - CB Certificate ▷ View online
Page 21 of 47
Report Ref No.: 614380
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
20 RESISTANCE
TO
FIRE
20.1
Electrical components and mechanical parts
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined
in 20.1
in 20.1
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c.
meets V-1 or better to IEC60707, unless used
in a fire enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c.
meets V-1 or better to IEC60707, unless used
in a fire enclosure
PCB P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
>400 V (peak) a.c. or d.c. meets V-0 to
IEC 60707
available power exceeds 15 W at a voltage
>400 V (peak) a.c. or d.c. meets V-0 to
IEC 60707
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source
than the distances in Table 21 comply with the
relevant flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source
than the distances in Table 21 comply with the
relevant flammability category in Table 21
Bobbins
Fuse holder
(see list of critical. components and
materials)
(see list of critical. components and
materials)
P
Components and parts as above but shielded
from a potential ignition source, with the barrier
area in accordance with Table 21 and fig. 13
from a potential ignition source, with the barrier
area in accordance with Table 21 and fig. 13
N/A
Apparatus with voltages > 4 kV under normal
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min
enclosure
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min
enclosure
N/A
20.2
Fire enclosure
20.2.1
Potential ignition sources with open circuit
voltage > 4 kV (peak) a.c. or d.c. contained in a
fire enclosure to V-1
voltage > 4 kV (peak) a.c. or d.c. contained in a
fire enclosure to V-1
N/A
20.2.2
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 22 of 47
Report Ref No.: 614380
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
A
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH PROTECTION
AGAINST SPLASHING WATER
AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does
not apply
not apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with
3.5.4 modified to 2.4.10 of this standard
3.5.4 modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with
4.1.2, 4.1.3 and 4.2.1.2 modified in accordance
with annex B of this standard
4.1.2, 4.1.3 and 4.2.1.2 modified in accordance
with annex B of this standard
N/A
Complies with IEC 62151 clause 5 but with
5.3.1 modified in accordance with annex B of
this standard
5.3.1 modified in accordance with annex B of
this standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Page 23 of 47
Report Ref No.: 614380
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
7.1 TABLE:
temperature
rise measurements: Conditions
P
Power consumption in the OFF/Stand-by mode
of the functional switch (W) ................................: 0W in OFF mode
—
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
1 253 50
0.37 63 9.8 24
1 2198 50 0.30 46 7.5 14
1/8 of max non-clipping output
power (pink noise). Input signal
connected to ’Line in L/R’ (See
instructions in OM Excerpt on page
3)
power (pink noise). Input signal
connected to ’Line in L/R’ (See
instructions in OM Excerpt on page
3)
Loudspeaker impedance (Ω) .............................: 4
—
Several loudspeaker systems
Built-in speaker
Marking of loudspeaker terminals
-
Temperature Rise dT of Part
dT (K)
Limit dT (K)
Test Condition No.
No 1
No ___
No ___
Core of transformer
38
-
Inside plastic cover
18
-
Supply cords (Not under mechanical stress)
22
60 (50)
Wiring insulation touching D115
30
60 (50)
Heat sink supported by PCB
25
85 (75)
PCB, near D115
25
85 (75)
Heat sink, on rear panel
20
40 (30)
Rear panel, near AC inlet
17
40 (30)
Knobs (plastic)
14
50 (40)
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ............................. :
23
—
—
—
—
Ambient temperature t2 (
o
C) ............................. :
25
—
—
—
—
Temperature rise dT of winding:
(
) (
)
1
2
1
5
,
234
1
1
2
t
t
t
R
-R
R
dT
−
−
+
×
=
⎟
⎟
⎠
⎠
⎞
⎜
⎜
⎝
⎝
⎛
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT
(K)
Insulation
class
Prim.
winding
9.210 10.870 44 85
(75) E
Sec. winding red-red
1.1041
1.275
38
85 (75)
E
Sec. winding yellow-yellow
0.555
0.647
41
85 (75)
E
Note: Values in parenthesis intended for tropical climates.
Page 24 of 47
Report Ref No.: 614380
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
9.1
Shock Hazard
P
Under normal operating conditions: > 35Vpk ac / 60V dc
Notes: Reference Annex D
Notes: Reference Annex D
-
CLASS I: (single phase)
AC DC
U1: -
Vpk
-
mA
rms
U1:
-
V
- mA
U2: -
Vpk
- mA rms
CLASS II: (single phase)
AC DC
U1: 0.018V
pk
- mA rms
U1: -
V
- mA
U2: 0.013V
pk
- mA rms
- mA
10.3
TABLE: Insulation Resistance Measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between the poles of the circuit directly connected to
the supply mains.
>10 Min.
2
Reinforced insulation.
>10 Min.
4
10.3
TABLE: Electric Strength Measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Between the poles of the circuit directly connected to the
supply mains.
2120V peak
No
Reinforced insulation.
4240V peak
No
Click on the first or last page to see other CS680 (serv.man2) service manuals if exist.