JBL CS (serv.man2) EMC - CB Certificate ▷ View online
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
4 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
2 S U M M A R Y
2.1 General
remarks
None
2.2 Final
assessment
The equipment under test
fulfills the EMC requirements cited in clause 1 test standards.
Date of receipt of test sample
:
acc. to storage records
Testing commenced on
:
05. December 2006
Testing concluded on
:
06. December 2006
Checked by:
Tested by:
Eduard Stangl
Dipl. Ing.(FH)
Technical Director
Michael
Hackl
EMC Senior Expert
Michael Hackl
2006.12.06
21:18:05
+01'00'
2006.12.06
21:18:05
+01'00'
Eduard Stangl
Ich bestätige die Richtigkeit
und Integrität dieses
Dokuments
2006.12.07 11:01:37 +01'00'
Ich bestätige die Richtigkeit
und Integrität dieses
Dokuments
2006.12.07 11:01:37 +01'00'
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
5 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
3 E Q U I P M E N T U N D E R T E S T
3.1
Photo documentation of the EuT
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
6 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
3.2
Power supply system utilised
Power supply voltage
: 230 V / 50 Hz / 1
φ
3.3
Short description of the Equipment under Test (EuT)
Powered subwoofer used for reproduction of audio information’s.
Number of tested samples:
1
Serial number:
none
Feature list:
- Single scart
- Headphone socket
- Audio input
- Double scart
- Front/side A/V input
- Audio output
- Triple scart
- Speaker output
- PiP module
- Teletext
- 50 Hz
- 100 Hz
- Double tuner
- PC in/out
- Mono
- Stereo
-
EuT operation mode:
The equipment under test was operated during the measurement under the following conditions:
- 60 Hz 1/8 rated output power
- Pink noise 1/8 rated output power
- 60 Hz audio signal
EuT configuration:
(The CDF filled by the applicant can be viewed at the test laboratory.)
The following peripheral devices and interface cables were connected during the measurements:
-
The following peripheral devices and interface cables were connected during the measurements:
-
Model
:
-
Model :
-
Model :
-
Model :
- unscreened power cables
- customer specific cables
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
7 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
3.4 Performance
level
The test results shall be classified in terms of the loss of function or degradation of performance of the equipment
under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed
between the manufacturer and the purchaser of the product.
under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed
between the manufacturer and the purchaser of the product.
Definition related to the performance level:
based on the used product standard
based on the declaration of the manufacturer, requestor or purchaser
Criterion A:
Definition: normal performance within limits specified by the manufacturer, requestor or purchaser:
The equipment shall continue to operate as intended during the test. No change of actual operating state (for
example change of channel) is allowed as a result of the application of the test. The criterion of compliance with
the requirement is a wanted to unwanted audio signal ratio of
≥ 40 dB at a wanted audio signal level of 50 mW,
or at another audio signal level specified by the manufacturer. No degradation of test picture is allowed.
Criterion B:
Definition: temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment
under test recovers its normal performance, without operator intervention:
under test recovers its normal performance, without operator intervention:
After the test, the equipment shall continue to operate as intended without operator intervention. No loss of
function is allowed after the test when the apparatus is used as intended, but failures which are recovered
automatically but which cause temporary delay in processing, are permissible. No change of actual operating state
is allowed as a result of the application of the test. During the test, degradation of performance is allowed.
Criterion C:
Definition: temporary loss of function or degradation of performance, the correction of which requires operator intervention:
Criterion D:
Definition: loss of function or degradation of performance, which is not recoverable, owing to damage to hardware or software, or loss of data:
Click on the first or last page to see other CS (serv.man2) service manuals if exist.