JBL CS (serv.man2) EMC - CB Certificate ▷ View online
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
12 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
5.2 Disturbance
power
For test instruments and accessories used see section 6 Part A 7.
5.2.1 Description of the test location
Test location:
Test location:
Shielded Room S7
5.2.2 Photo documentation of the test set-up
5.2.3 Test
result
Frequency range:
30 MHz - 300 MHz
Min. limit margin
>5 dB
The requirements are
FULFILLED.
Remarks:
For detailed results, please see the following page(s).
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
13 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
5.2.4 Test
protocol
Test point:
AC power line
Operation mode:
60 Hz 1/8 rated output power
Remarks: N/A
Date:
Date:
06. December 2006
Tested by:
Rüdiger Gramsch
Result: passed
30-300
<25
<25
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading
AV
[dBpW]
Limit QP
[dBpW]
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
< 25 dBpW
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
14 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
Test point:
Line input cable
Operation mode:
60 Hz 1/8 rated output power
Remarks: N/A
Date:
Date:
06. December 2006
Tested by:
Rüdiger Gramsch
Result: passed
85,450
33,0
20,0
-0,2
32,8
19,8
47,1
37,1
-14,3
-17,3
108,350
29,0
20,0
-0,7
28,3
19,3
47,9
37,9
-19,6
-18,6
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading
AV
[dBpW]
Limit QP
[dBpW]
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
15 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
Test point:
LFE input cable
Operation mode:
60 Hz 1/8 rated output power
Remarks: N/A
Date:
Date:
06. December 2006
Tested by:
Rüdiger Gramsch
Result: passed
82,800
33,0
21,0
0,3
33,3
21,3
47,0
37,0
-13,7
-15,7
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading
AV
[dBpW]
Limit QP
[dBpW]
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
Click on the first or last page to see other CS (serv.man2) service manuals if exist.