JBL CS (serv.man2) EMC - CB Certificate ▷ View online
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
28 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
S 2
SML 01
Signal Generator
Rohde & Schwarz München
02-02/05-05-004
6000N
RF Amplifier
PMM
02-02/17-05-001
UPL
Audio Analyzer
Rohde & Schwarz München
02-02/19-05-001
RCo 8 Ohm
RC Network
Erika Fiedler Messtechnik
02-02/22-05-025
RCi 47 kOhm
RC Network
Erika Fiedler Messtechnik
02-02/22-05-029
MSF
Mains Filter
Erika Fiedler Messtechnik
02-02/22-05-067
PSU
RF Relaismatrix
Rohde & Schwarz München
02-02/50-05-002
JFW 50FHC-006-25
RF Attenuator 6 dB/25 W
jfw
02-02/50-05-020
ZFSC-2-2
Power Splitter
6011
Power Divider DC-118 GH Tactron Elektronik
02-02/50-05-080
S 3
SML 01
Signal Generator
Rohde & Schwarz München
02-02/05-05-004
URV 35
RF Voltmeter
Rohde & Schwarz München
02-02/07-05-009
URV 5 - Z 7
RF Probe
Rohde & Schwarz München
02-02/07-05-011
6000N
RF Amplifier
PMM
02-02/17-05-001
UPL
Audio Analyzer
Rohde & Schwarz München
02-02/19-05-001
Mains Stop Filter S3
Mains Stop Filter S3
Erika Fiedler Messtechnik
02-02/22-05-070
LBS
Band-Stop-Filter
Erika Fiedler Messtechnik
02-02/22-05-071
Open Strip Line
Open Strip Line
Natural Audio Lautsprecher
02-02/24-05-011
PSU
RF Relaismatrix
Rohde & Schwarz München
02-02/50-05-002
ZFSC-2-2
Power Splitter
6011
Power Divider DC-118 GH Tactron Elektronik
02-02/50-05-080
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
29 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
7 T e s t p r o t o c o l ( s )
7.1
Immunity requirements - S2 Test protocol(s)
Test point (injection into) : LFE
Mode of EUT : LFE
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker woofer
Output : 51 mW/4 Ohm
Channel : mono
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 05.12.2006
Place : Immunity Site 1
Test point (injection into) : LFE
Mode of EUT : LINE LEVEL IN
Criterion : Sound
Ref.-S/N : 55 dB
Monitoring : Speaker woofer
Output : 52 mW/4 Ohm
Channel : mono
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 05.12.2006
Place : Immunity Site 1
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
30 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
Test point (injection into) : LINE LEVEL IN
Mode of EUT : LFE
Criterion : Sound
Ref.-S/N : 56 dB
Monitoring : Speaker woofer
Output : 52 mW/4 Ohm
Channel : mono
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 05.12.2006
Place : Immunity Site 1
Test point (injection into) : LINE LEVEL IN
Mode of EUT : LINE LEVEL IN
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker woofer
Output : 50 mW/4 Ohm
Channel : mono
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 05.12.2006
Place : Immunity Site 1
Test point (injection into) : MAINS
Mode of EUT : LFE
Criterion : Sound
Ref.-S/N : 56 dB
Monitoring : Speaker woofer
Output : 52 mW/4 Ohm
Channel : mono
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 05.12.2006
Place : Immunity Site 1
mikes-testingpartners gmbh
File
No.
F31352-00-00HM
, page
31 of 32
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.2
Test point (injection into) : MAINS
Mode of EUT : LINE LEVEL IN
Criterion : Sound
Ref.-S/N : 58 dB
Monitoring : Speaker woofer
Output : 52 mW/4 Ohm
Channel : mono
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 05.12.2006
Place : Immunity Site 1
Click on the first or last page to see other CS (serv.man2) service manuals if exist.