DOWNLOAD JBL CREATURE III (serv.man6) Service Manual ↓ Size: 1.27 MB | Pages: 127 in PDF or view online for FREE

Model
CREATURE III (serv.man6)
Pages
127
Size
1.27 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
creature-iii-sm6.pdf
Date

JBL CREATURE III (serv.man6) EMC - CB Certificate ▷ View online

 
Page 5 of 38
 
Report No. : W12-950-062
 
TRF No. IECEN60950_1C 
 
Korea Testing Certification
 
 
Test item particulars
 ................................................... :  
Equipment mobility..................................................... : [x] movable     [] hand-held       [] transportable 
[] stationary  [] for building-in  [] direct plug-in 
Connection to the mains ............................................ : [] pluggable equipment   [] type A   [] type B 
[] permanent connection 
[] detachable power supply cord      
[] non-detachable power supply cord 
[x] not directly connected to the mains 
Operating condition .................................................... : [x] continuous 
[] rated operating / resting time:  
Access location  ......................................................... : [x] operator accessible 
[] restricted access location 
Over voltage category (OVC)  ................................... : [] OVC I     [x] OVC II     [] OVC III     [] OVC IV 
[x] other: Not directly connected to the mains 
Mains supply tolerance (%) or absolute mains 
supply values  ............................................................ :
Not directly connected to the mains 
Tested for IT power systems  .................................... : [ ] Yes     [x] No 
IT testing, phase-phase voltage (V)  .......................... : N/A 
Class of equipment  ................................................... : [] Class I     [] Class II     [x] Class III      
[] Not classified 
Considered current rating of protective device as 
part of the building installation (A)  ............................ :
N/A 
Pollution degree (PD)  ............................................... : [] PD 1     [x] PD 2     [] PD 3 
IP protection class  .................................................... : IPX0 
Altitude during operation (m)  .................................... : 2000 
Altitude of test laboratory (m)  .................................... : <500m 
Mass of equipment (kg)  ............................................ : 1.6kg 
Possible test case verdicts:
 
 
- test case does not apply to the test object ................. : N/A (or N) 
- test object does meet the requirement....................... : P (Pass) 
- test object does not meet the requirement ................ : F (Fail) 
Testing
 .......................................................................... :  
Date of receipt of test item ............................................ : 2012-11-01 
Date(s) of performance of tests .................................... : From 2012-11-01 to 2012-11-20 
 
Page 6 of 38
 
Report No. : W12-950-062
 
TRF No. IECEN60950_1C 
 
Korea Testing Certification
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report a 
 comma / 
 point is used as the decimal separator. 
 
 
 
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: 
The application for obtaining a CB Test Certificate 
includes more than one factory location and a 
declaration from the Manufacturer stating that the 
sample(s) submitted for evaluation is (are) 
representative of the products from each factory has 
been provided ................................................................:
 Yes 
 Not applicable 
 
When differences exist; they shall be identified in the General product information section. 
Name and address of factory (ies) .......................... : Zhao Yang Electronic (ShenZhen) Co., Ltd. 
Section A, 4
th
 Floor, Building 1 & Building 2, De 
Yong Jia Industrial Park, Guang Qiao Road, Yu Lv 
Community, Gong Ming Street, Guang Ming New 
District, Shenzhen, P. R. China 
General product information: 
1. The speaker contains only secondary (SELV) circuit and the maximum operating temperature is 35
°C; 
2. The equipment’s Rear enclosure is secured to plastic enclosure by screw; 
3. The EUT is supplied by an approved AC/DC adapter (SPS) provided only;  
4. A separated certified external AC/DC adaptor complied with limited power sources according to IEC/EN 
60950-1 should be used (see appended tables 1.5.1); 
5. The EUT can be connected to the approved SPS via DC connector.   
 
 
 
 
Abbreviations used in the report: 
 
- normal conditions  
           N.C.   
 
 
- single fault conditions 
 
S.F.C 
functional 
insulation  OP 
   - 
basic 
insulation 
  BI 
double 
insulation 
  DI 
   - 
supplementary 
insulation 
SI 
- between parts of opposite 
 
 
polarity 
   BOP 
   - 
reinforced 
insulation 
 RI 
 
Indicate used abbreviations (if any) 
 
 
 
 
 
Page 7 of 38 
 
Report No. : W12-950-062
 
 
  
IEC 
60950-1/Am1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IECEN60950_1C 
 
Korea Testing Certification
 
1 GENERAL 
 
1.5 Components 
1.5.1 General 
 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended tables 1.5.1) 
1.5.2 
Evaluation and testing of components 
 
1.5.3 
Thermal controls 
No thermal controls 
N/A 
1.5.4 
Transformers 
No isolating transformers 
N/A 
1.5.5 Interconnecting 
cables 
 
N/A 
1.5.6 
Capacitors bridging insulation  
 
N/A 
1.5.7 
Resistors bridging insulation 
 
N/A 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
 N/A 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
 N/A 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable  
 N/A 
1.5.8 
Components in equipment for IT power systems 
 
N/A 
1.5.9 Surge 
suppressors 
 
N/A 
1.5.9.1 General 
 
N/A 
1.5.9.2 
Protection of VDRs 
 
N/A 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
N/A 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 N/A 
 
1.6 Power 
interface 
1.6.1 
AC power distribution systems 
Not directly connect to the 
mains 
N/A 
1.6.2 Input 
current 
(see appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
 
N/A 
1.6.4 
Neutral conductor  
Not directly connect to the 
mains 
N/A 
 
1.7 
Marking and instructions 
1.7.1 
Power rating and identification markings 
 
 
Page 8 of 38 
 
Report No. : W12-950-062
 
 
  
IEC 
60950-1/Am1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IECEN60950_1C 
 
Korea Testing Certification
 
1.7.1.1 
Power rating marking 
 
 
Multiple mains supply connections..........................:  N/A 
 
Rated voltage(s) or voltage range(s) (V)  .............. : 12  Vdc 
 
Symbol for nature of supply, for d.c. only ............... : DC Symbol used 
 
Rated frequency or rated frequency range (Hz)  ... :  
N/A 
 
Rated current (mA or A)  ........................................ : 3.0 A 
1.7.1.2 Identification 
markings 
 
 
Manufacturer’s name or trade-mark or identification 
mark  ...................................................................... :
 
 
Model identification or type reference  ................... : jbl creature III 
 
Symbol for Class II equipment only  ...................... : Class III equipment 
N/A 
 
Other markings and symbols  ................................ :  
N/A 
1.7.2 
Safety instructions and marking 
Installation and Operating 
Instructions provided 
1.7.2.1 General 
 
1.7.2.2 Disconnect 
devices 
 
N/A 
1.7.2.3 Overcurrent 
protective device 
 
N/A 
1.7.2.4 
IT power distribution systems 
 
N/A 
1.7.2.5 
Operator access with a tool 
 
N/A 
1.2.7.6 Ozone 
 
N/A 
1.7.3 
Short duty cycles 
Equipment is designed for 
continuous operation 
N/A 
1.7.4 
Supply voltage adjustment  ................................... : 
No  power selector 
N/A 
 
Methods and means of adjustment; reference to 
installation instructions  ......................................... : 
 N/A 
1.7.5 
Power outlets on the equipment  .......................... : 
 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference)  .......................... : 
 N/A 
1.7.7 Wiring 
terminals 
 
N/A 
1.7.7.1 Protective 
earthing 
and bonding terminals  .......... :   
N/A 
1.7.7.2 
Terminals for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
 
N/A 
1.7.8.1 Identification, location and marking  ...................... : 
 
N/A 
1.7.8.2 Colours 
  ................................................................ :   
N/A 
1.7.8.3 Symbols 
according to IEC 60417 ......................... : 
 
N/A 
1.7.8.4 Markings 
using 
figures   ....................................... : 
 
N/A 
Page of 127
Display

Click on the first or last page to see other CREATURE III (serv.man6) service manuals if exist.