JBL CINEMA SOUND 5 (serv.man2) EMC - CB Certificate ▷ View online
Report No. JSH006110138-001
Page 32 of 94
Rear USB Horizontal:
0
10
20
30
40
50
60
70
80
Level [dB
/m]
礦
30M
50M
70M
100M
200M
300M
500M
700M
1G
Frequency [Hz]
x
x
MES cs5_H3_red
MES cs5_H3_pre
LIM EN 55022 F 3 QP
MES cs5_H3_pre
LIM EN 55022 F 3 QP
Field Strength QP
Rear USB Vertical:
0
10
20
30
40
50
60
70
80
Level [dB
/m]
礦
30M
50M
70M
100M
200M
300M
500M
700M
1G
Frequency [Hz]
x
x
x
x
x
x
MES cs5_v3_red
MES cs5_v3_pre
LIM EN 55022 F 3 QP
MES cs5_v3_pre
LIM EN 55022 F 3 QP
Field Strength QP
Report No. JSH006110138-001
Page 33 of 94
5.5 Measurement uncertainty
The measurement uncertainty describes the overall uncertainty of the given measured value
during the operation of the EUT.
Measurement uncertainty is calculated in accordance with CISPR 16-4-2: 2003.
Measurement uncertainty of mains terminal disturbance voltage :
during the operation of the EUT.
Measurement uncertainty is calculated in accordance with CISPR 16-4-2: 2003.
Measurement uncertainty of mains terminal disturbance voltage :
± 5.2dB
The measurement uncertainty is given with a confidence of 95%, k=2.
5.6 Additions, Deviations and Exclusions from Standards
None
Report No. JSH006110138-001
Page 34 of 94
6. Harmonics
Test result:
PASS
6.1 Block Diagram of Test Setup
6.2 Test Setup and Test Procedure
Harmonics of the fundamental current were measured up to 40 order harmonics using a digital
power
meter with an analogue output and frequency analyser which was integrated in the harmonic &
flicker
test system. The measurements were carried out under steady conditions .
The appliance has rated input power less than 75W, and is not luminaire , and according to the
standards, no limit apply.
6.2.1 Photo For test Set-up
Harmonic & flicker
test system
test system
EUT
Report No. JSH006110138-001
Page 35 of 94
6.3 Test Protocol
Temperature :
20
°C
Relative
Humidity:
45%
Test Result: Pass
Source qualification: Normal
U
Current & voltage waveforms
U
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
U
Harmonics and Class A limit line
U
U
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
U
Test result: Pass Worst harmonic was #39 with 6.01% of the limit.