Sony CPD-G220 Service Manual ▷ View online
CHASSIS
SERVICE MANUAL
SPECIFICATIONS
CPD-G220
17VC
AEP Model
Chassis No. SCC-L38A-A
TORINITORON
®
COLOR GRAPHIC DISPLAY
CRT
0.24 mm aperture grille pitch(center)
17 inches measured diagonally
90-degree deflection
FD Trinitron
17 inches measured diagonally
90-degree deflection
FD Trinitron
Viewable image size
Approx. 327
×
243 mm (w/h)
×
(12 9 inches)
Resolution
Maximum Horizontal: 1600 dots
Vertical: 1200 lines
Vertical: 1200 lines
Recommended Horizontal: 1024 dots
Vertical: 768 lines
Vertical: 768 lines
Standard image area
Deflection frequency*
AC input voltage/current 100 to 240 V, 50/60 Hz, Max. 1.7A
Power consumption
Power consumption
Approx. 115 W
(without USB operation)
Dimensions
Approx. 402
×
418
×
421mm (w/h/d)
(15
7
/
8
×
16
1
/
2
×
16
Mass
Approx. 19 kg (41.9 lb 1 oz)
Plug and Play
DDC2B/DDC2Bi
GTF**
GTF**
Supplied accessories Power cord(1)
Macintosh G3/G4 adapter(1)
USB cable(1)
Warranty card(1)
Notes on cleaning the screen's surface(1)
Instruction manual(1)
USB cable(1)
Warranty card(1)
Notes on cleaning the screen's surface(1)
Instruction manual(1)
*Recommended horizontal and vertical timing condition
•Horizontal sync width should be more than 1.0
•Horizontal sync width should be more than 1.0
µ
sec.
•Horizontal blanking width should be more than 3.0
µ
sec.
•Vertical blanking width should be more than 500
µ
sec.
**If the input signal is Generalized Timing Formula(GTF)
compliant, the GTF feature of the monitor will automatically
provide an optical image for the screen.
Design and specification are subject to change without notice.
Approx. 312
×
234 mm (w/h)
(12
3
/
8
×
9
1
/
4
inches)
Horizontal: 30 to 96 kHz
Vertical: 48 to 170 Hz
Vertical: 48 to 170 Hz
viewing image Approx. 408 mm (16.0 inches)
5
/
8
inches)
7
/
8
5
/
8
CPD-G220(E)
2
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all
exposed metal parts to any exposed metal part having a return to chassis,
must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-
exposed metal parts to any exposed metal part having a return to chassis,
must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-
540A. Follow the manufacturers’ instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital
multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or
battery-operated AC voltmeter. The “limit” indication is 0.75 V, so
analog meters must have an accurate low-voltage scale. The Simpson 250
and Sanwa SH-63Trd are examples of a passive VOMs that are suitable.
Nearly all battery operated digital multimeters that have a 2 V AC range
are suitable. (See Fig. A)
analog meters must have an accurate low-voltage scale. The Simpson 250
and Sanwa SH-63Trd are examples of a passive VOMs that are suitable.
Nearly all battery operated digital multimeters that have a 2 V AC range
are suitable. (See Fig. A)
After correcting the original service problem, perform the following safety
checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-soldered
checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-soldered
connections. Check the entire board surface for solder splashes and
bridges.
bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or
contact high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and
mounting hardware have been replaced. Be absolutely certain that you
have replaced all the insulators.
have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly transistors, that
were installed during a previous repair. Point them out to the customer
and recommend their replacement.
and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of
deterioration. Point them out to the customer and recommend their
replacement.
replacement.
6. Check the line cords for cracks and abrasion. Recommend the
replacement of any such line cord to the customer.
7. Check the B+ and HV to see if they are specified values. Make sure your
instruments are accurate; be suspicious of your HV meter if sets always
have low HV.
have low HV.
8. Check the antenna terminals, metal trim, “metallized” knobs, screws, and
all other exposed metal parts for AC Leakage. Check leakage as
described right.
described right.
Fig. A. Using an AC voltmeter to check AC leakage.
1.5 k
Ω
0.15
µ
F
AC
Voltmeter
(0.75 V)
Voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Parts on Set
Earth Ground
SAFETY CHECK-OUT
CPD-G220(E)
3
WARNING!!
NEVER TURN ON THE POWER IN A CONDITION IN WHICH THE
DEGAUSS COIL HAS BEEN REMOVED.
DEGAUSS COIL HAS BEEN REMOVED.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY SHADING AND MARK
!
ON THE
SCHEMATIC DIAGRAMS, EXPLODED VIEWS AND IN THE
PARTS LIST ARE CRITICAL FOR SAFE OPERATION. REPLACE
THESE COMPONENTS WITH SONY PARTS WHOSE PART
NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN
SUPPLEMENTS PUBLISHED BY SONY. CIRCUIT ADJUST-
MENTS THAT ARE CRITICAL FOR SAFE OPERATION ARE
IDENTIFIED IN THIS MANUAL. FOLLOW THESE PROCEDURES
WHENEVER CRITICAL COMPONENTS ARE REPLACED OR IM-
PROPER OPERATION IS SUSPECTED.
PARTS LIST ARE CRITICAL FOR SAFE OPERATION. REPLACE
THESE COMPONENTS WITH SONY PARTS WHOSE PART
NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN
SUPPLEMENTS PUBLISHED BY SONY. CIRCUIT ADJUST-
MENTS THAT ARE CRITICAL FOR SAFE OPERATION ARE
IDENTIFIED IN THIS MANUAL. FOLLOW THESE PROCEDURES
WHENEVER CRITICAL COMPONENTS ARE REPLACED OR IM-
PROPER OPERATION IS SUSPECTED.
AVERTISSEMENT!!
NE JAMAIS METTRE SOUS TENSION QUAND LA BOBINE DE
DEMAGNETISATION EST ENLEVÉE.
DEMAGNETISATION EST ENLEVÉE.
ATTENTION AUX COMPOSANTS RELATIFS À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE TRAME ET UNE
MARQUE
MARQUE
!
SONT CRITIQUES POUR LA SÉCURITÉ. NE LES
REMPLACER QUE PAR UNE PIÈCE PORTANT LE NUMÉRO
SPECIFIÉ. LES RÉGLAGES DE CIRCUIT DONT L’IMPORTANCE EST
CRITIQUE POUR LA SÉCURITÉ DU FONCTIONNEMENT SONT
IDENTIFIÉS DANS LE PRÉSENT MANUEL. SUIVRE CES
PROCÉDURES LORS DE CHAQUE REMPLACEMENT DE
COMPOSANTS CRITIQUES, OU LORSQU’UN MAUVAIS
FONCTIONNEMENT EST SUSPECTÉ.
SPECIFIÉ. LES RÉGLAGES DE CIRCUIT DONT L’IMPORTANCE EST
CRITIQUE POUR LA SÉCURITÉ DU FONCTIONNEMENT SONT
IDENTIFIÉS DANS LE PRÉSENT MANUEL. SUIVRE CES
PROCÉDURES LORS DE CHAQUE REMPLACEMENT DE
COMPOSANTS CRITIQUES, OU LORSQU’UN MAUVAIS
FONCTIONNEMENT EST SUSPECTÉ.
CPD-G220(E)
4
POWER SAVING FUNCTION
This monitor meets the power-saving guidelines set by VESA, TCO’99,
and
and
E
NERGY
S
TAR. If no signal is input to the monitor from your
computer, the monitor will automatically reduce power consumption as
shown below.
shown below.
*
1
Figures reflect power consumption when no USB compatible
peripherals are connected to the monitor.
peripherals are connected to the monitor.
*
2
When your computer enters power saving mode, NO SIGNAL appears
on the screen. After a few seconds, the monitor enters power saving
mode.
on the screen. After a few seconds, the monitor enters power saving
mode.
*
3
“Deep sleep” is power saving mode defined by the Environmental
Protection Agency.
Protection Agency.
Power mode
Power consumption
*
1
f
(power)
indicator
normal operation
≤
115 W (without USB operation)
green
active off*
2
(deep sleep)*
3
≤
3 W
orange
power off
0 W (approximately)
off