JBL CINEMA SOUND 5 (serv.man2) EMC - CB Certificate ▷ View online
Report No. JSH006110138-001
Page 36 of 94
Current Test Result Summary (Run time)
Test Result: Pass
Source qualification: Normal
THC(A): 0.02 I-THD(pk%): 15.63 POHC(A): 0.007 POHC Limit(A): 0.251
Highest parameter values during test:
Highest parameter values during test:
V_RMS (Volts): 229.74
Frequency(Hz): 60.00
I_Peak (Amps): 0.295
I_RMS (Amps): 0.156
I_Fund (Amps): 0.153
Crest Factor:
1.909
Power (Watts): 30.7
Power Factor:
0.855
Harm# Harms(avg) 100%Limit %of
Limit Harms(max) 150%Limit %of
Limit Status
2 0.001 1.080 0.1
0.001 1.620 0.06
Pass
3 0.020 2.300 0.9
0.020 3.450 0.59
Pass
4 0.000 0.430 0.1
0.001 0.645 0.08
Pass
5 0.005 1.140 0.5
0.006 1.710 0.33
Pass
6 0.000 0.300 0.1
0.000 0.450 0.08
Pass
7 0.005 0.770 0.6
0.005 1.155 0.42
Pass
8 0.000 0.230 0.2
0.000 0.345 0.13
Pass
9 0.001 0.400 0.3
0.001 0.600 0.19
Pass
10 0.000 0.184 0.2
0.001 0.276 0.19
Pass
11 0.004 0.330 1.1
0.004 0.495 0.73
Pass
12 0.000 0.153 0.3
0.001 0.230 0.23
Pass
13 0.002 0.210 1.1
0.002 0.315 0.77
Pass
14 0.000 0.131 0.3
0.001 0.197 0.25
Pass
15 0.002 0.150 1.5
0.002 0.225 1.05
Pass
16 0.000 0.115 0.4
0.000 0.173 0.28
Pass
17 0.002 0.132 1.5
0.002 0.199 1.08
Pass
18 0.000 0.102 0.3
0.000 0.153 0.24
Pass
19 0.001 0.118 1.0
0.001 0.178 0.70
Pass
20 0.000 0.092 0.4
0.000 0.138 0.28
Pass
21 0.002 0.107 1.9
0.002 0.161 1.30
Pass
22 0.000 0.084 0.4
0.000 0.125 0.33
Pass
23 0.002 0.098 2.0
0.002 0.147 1.36
Pass
24 0.000 0.077 0.6
0.001 0.115 0.44
Pass
25 0.002 0.090 2.4
0.002 0.135 1.64
Pass
26 0.000 0.071 0.6
0.001 0.106 0.50
Pass
27 0.001 0.083 1.5
0.001 0.125 1.07
Pass
28 0.000 0.066 0.5
0.000 0.099 0.40
Pass
29 0.001 0.078 1.3
0.001 0.116 0.90
Pass
30 0.000 0.061 0.5
0.000 0.092 0.40
Pass
31 0.001 0.073 1.4
0.001 0.109 1.01
Pass
32 0.000 0.058 0.6
0.000 0.086 0.46
Pass
33 0.001 0.068 2.0
0.001 0.102 1.43
Pass
34 0.000 0.054 0.8
0.000 0.081 0.59
Pass
35 0.002 0.064 2.9
0.002 0.096 2.06
Pass
36 0.001 0.051 1.1
0.001 0.077 0.83
Pass
37 0.002 0.061 3.7
0.002 0.091 2.54
Pass
38 0.001 0.048 1.8
0.001 0.073 1.35
Pass
39 0.005 0.058 8.7
0.005 0.087 6.01
Pass
40 0.001 0.046 1.9
0.001 0.069 1.52
Pass
6.4 Measurement Uncertainty
The measurement uncertainty for harmonic test is under consideration according to CISPR 16-
4:2002
4:2002
6.5 Additions, Deviations and Exclusions from Standards
None
Report No. JSH006110138-001
Page 37 of 94
7. Voltage Fluctuations-Flicker
Test result
PASS
7.1 Block Diagram of Test Setup
7.2 Test Setup and Test Procedure
7.2.1 Definition
Flicker:
impression of unsteadiness of visual sensation induced by a lighting stimulus whose
luminance or spectral distribution fluctuates with time.
Pst:
Short-term flicker indicator The flicker severity evaluated over a short period (in
minutes); Pst=1 is the conventional threshold of irritability
Plt:
long-term flicker indicator; the flicker severity evaluated over a long period (a few
hous)
Using successive Pst valuse.
dc:
the relative steady-state voltage change
dmax:
the maximum relative voltage change
d(t):
the value during a voltage change
7.2.2 Photo For test Set-up
none
Harmonic & flicker
test system
test system
EUT
Report No. JSH006110138-001
Page 38 of 94
7.3 Test Protocol
The tested object operated under the operating condition specified in EN61000-3-
3:1995/+A1:2001
The following limits apply
-- “dc” shall not exceed 3.3%.
-- “dmax” shall not exceed 4/6/7%
-- d(t) shall not exceed 3.3% for more than 500ms.
-- “dmax” shall not exceed 4/6/7%
-- d(t) shall not exceed 3.3% for more than 500ms.
The appliance has rated input power less than 75W, and it has no means to
generate significant voltage flick and fluctuation, No test required.
Temperature
:
20
°C
Relative Humidity
:
45 %
Test Result: Pass
Status: Test Completed
U
Pst
UBU
i
UBU
and limit line
U
U
U
0.25
0.50
0.75
1.00
Pst
15:35:10
U
Plt and limit line
U
4.25
4.50
4.75
Plt[e-2]
15:35:10
Parameter values recorded during the test:
Vrms at the end of test (Volt):
Vrms at the end of test (Volt):
229.70
Highest dt (%):
-0.42
Test limit (%):
3.30
Pass
Time(mS) > dt:
0.0
Test limit (mS):
500.0
Pass
Highest dc (%):
0.00
Test limit (%):
3.30
Pass
Highest dmax (%):
-0.39
Test limit (%):
4.00
Pass
Highest Pst (10 min. period): 0.103
Test limit: 1.000
Pass
Report No. JSH006110138-001
Page 39 of 94
Notes: * means for
4% limit, without additional conditions
6% limit, switched manually or automatically more than twice per day
7% limit, switched automatically for no more than twice per day or attended
while in use.
7.4 Measurement Uncertainty
Measurement uncertainty for voltage fluctuation and flicker is under consideration according to
CISPR 16-4-2:2003.
7.5 Additions, deviations and exclusions from standards
None
Click on the first or last page to see other CINEMA SOUND 5 (serv.man2) service manuals if exist.