                                                                            Page 8 of 64                   Report No. JSH006110064-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such High voltage 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. :
U1= 11.3Vp 
U2= 0.12Vp 
 
Discharge not exceeding 45 μC 1 
μC P 
 
 
Energy of discharge not exceeding 350 mJ 
No voltage exceeding 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 P 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
Holes with 3.7mm x 3.7 mm 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
         
 P 
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
         
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
         
 N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
9.9V P 
 
If C is not greater than 0,1 μF no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 P 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 P 
 
Test hook of fig. 4 for 10 s (20 N) 
 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N P 
9.2 
No hazard after removing a cover by hand 
Can not be removed by hand 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
(See appended table) 
10.2 Humidity 
treatment 48 h or 120 h ........................... : 48h, 30℃, 93%R.H. 
10.3 
Insulation resistance and dielectric strength 
(See appended table) 
 
 
                                                                            Page 9 of 64                   Report No. JSH006110064-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
11 FAULT 
CONDITIONS 
 
11.1 
No shock hazard under fault condition 
         
 P 
11.2 
Heating under fault condition 
         
 P 
 
No hazard from softening solder 
         
 P 
11.2.1 
Measurement of temperature rises 
 
P  
11.2.2 
Temperature rise of accessible parts 
 
P  
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(See appended table) 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
         
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
         
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
         
 N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 P 
11.2.5 
Temperature rise of windings 
(see appended table) 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table) 
 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
6.3kg 
N/A 
12.1.2 Vibration 
test 
Not carried out, no connection 
which might impair safety can 
become loosen 
12.1.3 
Impact hammer test 
0.5J P 
 
Steel ball test 
2J P 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
 P 
12.1.5 
Thermoplastic enclosures stress relief test 
70
o
C, 7h 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
 
                                                                            Page 10 of 64                   Report No. JSH006110064-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
12.3 
Remote controls with hazardous live parts 
         
 N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
         
 P 
12.5 
Antenna coaxial sockets providing isolation 
         
 N/A 
 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
 
 
Creepage distances in accordance with 13.4 
 
13.2 
Determination of operating voltage 
T501 pin 5,6 – pin 13,14,15   
313Vrms, 476Vp 
T502 pin 3 – pin 15   370Vrms, 
588Vp 
T502 pin 6 – pin 12,13,18   
182Vrms, 412Vp 
13.3 
Clearances 
(see appended table) 
P  
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
 P 
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
 P 
 
13.4 
Creepage distances 
(see appended table) 
 
Creepage distances greater than table 11 minima 
         
 P 
13.5 Printed 
boards 
         
 N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
         
 N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
         
 N/A 
 
                                                                            Page 11 of 64                   Report No. JSH006110064-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
         
 N/A 
 
 
14 COMPONENTS 
 
14.1 Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
R575 P 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 Resistors 
separately approved  .............................. : By VDE 
14.2 
Capacitors and RC units 
         
 P 
 
Capacitors separately approved 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y1: CY1, CY2, CY501, CY502 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2: C501, C502, C503 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such capacitor 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
No such capacitor 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
 
N/A 
 
Shielded by a barrier to V-0 or metal  ..................... :  
N/A 
14.3 
Inductors and windings 
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type .............................. :
Switching mode transformer  
T501: BCK-EC4201 
T502: BCK-ER2855 
Filter L512, L513: 
LCL-ET2812 
 
Transformers and inductors separately approved . :  
N/A 
14.3.2 General 
 
14.3.3 Constructional 
requirements 
 
Page of 65