JBL CINEMA SOUND 3 (serv.man3) EMC - CB Certificate ▷ View online
Page 24 of 64 Report No. JSH006110064-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
20.1
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1 excluding metal, glass and ceramic.
20.1 excluding metal, glass and ceramic.
P
Page 25 of 64 Report No. JSH006110064-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.1
TABLE: rated current/power consumption
P
Model
Input voltage
(V)
(V)
Rated
current
(mA)
current
(mA)
Measured
current
(mA)
current
(mA)
Rated
power (W)
power (W)
Measured
power (W)
power (W)
condition/status
100 -- 381
300
37.8
CINEMA
SOUND 3
240 -- 178
300
37.5
DVD player
-- -- -- -- --
--
-- -- -- -- --
--
-- -- -- -- --
--
-- -- -- -- --
--
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
Stand-by: 1.7W Max.
—
Position of the functional switch (W) ...................... : On
—
Room temperature t1 (°C) ...................................: N/A
Room temperature t2 (°C) ...................................: N/A
Operating conditions
Normal DVD playing, with 1/8 non-clipped 400Hz sinusoidal output power to the speaker, operates 4 hours
until steady condition reached. Ambient 24
until steady condition reached. Ambient 24
o
C.
Un (V)
In (mA)
Pn (W)
Pout (V / mA)
264 169
37.4
--
240 178
37.6
--
100 381
37.8
--
90 424
38.3
--
Loudspeaker impedance (Ω) ................................. :
6Ω X 5
—
Several loudspeaker systems
5 channel speakers
P
Marking of loudspeaker terminals
Printed on rear enclosure
P
dT (K)
monitored point:
90V
264V
Permitted dT (K)
Power cord
1
1
60
Inlet 13
13
60
22 21 60
Page 26 of 64 Report No. JSH006110064-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Operating conditions
Fuse holder
31
23
--
CY501 (Y1 capacitor)
18
16
60 (85-25)
C503(X2 capacitor)
28
23
60 (85-25)
C502 (X2 capacitor )
23
19
60 (85-25)
C501 (X2 capacitor )
22
18
60 (85-25)
PCB near D508
31
27
85
Winding of L512
25
20
75*
EC502 (electrolytic capacitor)
27
22
80 (105-25)
Winding of L501
28
20
75*
PCB near Q501
28
24
85
PCB near Q504
27
24
85
Winding of T501
31
28
75*
Bobbin of T501
30
28
75
Winding of T502
35
33
75*
Bobbin of T502
34
32
75
PCB near U404(on amplifier board)
38
35
85
PCB near D501
32
31
85
Enclosure (metallic)
16
15
40
Enclosure (non-metallic)
10
8
60
EC405 (electrolytic capacitor)
28
24
80 (105-25)
EC406 (electrolytic capacitor)
32
29
80 (105-25)
EC407 (electrolytic capacitor)
22
20
80 (105-25)
* The limit value reduced by 10K due to the thermal coupler method used.
winding temperature rise measurements:
Temperature rise dT of winding:
R1 (Ω) R2 (Ω)
dT (K)
required
dT (K)
dT (K)
Insulation
class
class
--
-- -- -- -- --
--
--
-- -- -- -- --
--
-- -- -- -- --
--
--
-- -- -- -- --
10.3
TABLE: insulation resistance measurements
P
Page 27 of 64 Report No. JSH006110064-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between poles of the circuit directly connected to the mains
100
2
Between Pri. and Sec. circuits
10
4
Between Pri. circuit and accessible parts
10
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Between poles of the circuit directly connected to the mains
2120 V peak
No
Between Pri. and Sec. circuits
4240 V peak
No
Between Pri. circuit and accessible parts
4240 V peak
No
11.2
TABLE: summary of fault condition tests
P
Model/type of power supply .................................: A.C. power supply
—
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 90 - 264
Ambient temperature (
o
C) ...................................... : 24
—
No. Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse
No.
Fuse
current
(A)
Result
Dielectric
strength
test after
the test
1. D514 SC 264 30
m
F501
0.188
18.3W consumption, circuit
protected, no high
temperature, no hazard,
recoverable when fault
removed
protected, no high
temperature, no hazard,
recoverable when fault
removed
Pass
2. D515 SC 264 5
m
F501
0.079
4.6W consumption, circuit
protected, no high
temperature, no hazard,
recoverable when fault
removed
protected, no high
temperature, no hazard,
recoverable when fault
removed
Pass
3. D516 SC 264 30
m
F501
0.184
18.4W consumption, circuit
protected, no high
temperature, no hazard,
recoverable when fault
removed
protected, no high
temperature, no hazard,
recoverable when fault
removed
Pass
4. D519 SC 264 15
m
F501
0.132
11.2W consumption, circuit
protected, no high
temperature, no hazard,
recoverable when fault
removed
protected, no high
temperature, no hazard,
recoverable when fault
removed
Pass