DOWNLOAD JBL CINEMA SOUND 3 (serv.man2) Service Manual ↓ Size: 1.98 MB | Pages: 95 in PDF or view online for FREE

Model
CINEMA SOUND 3 (serv.man2)
Pages
95
Size
1.98 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
cinema-sound-3-sm2.pdf
Date

JBL CINEMA SOUND 3 (serv.man2) EMC - CB Certificate ▷ View online

 
 
Report No. JSH006110139-001 
Page 60 of 94  
Indirect contact discharges were applied to the VCP and the HCP at the following selected points: 
Point Description 
Point 
Result 
HCP f 
0,1m from the front of the EUT 
Edge of centre,coner  on HCP 
HCP b 
0,1m from the back of the EUT 
Edge of centre,coner  on HCP 
HCP r 
0,1m from the right side of the EUT 
Edge of centre,coner  on HCP 
HCP l 
0,1m from the left side of the EUT 
Edge of centre,coner  on HCP 
VCP f 
0,1m from the front of the EUT 
Edge of centre,coner  on VCP 
VCP b 
0,1m from the back of the EUT 
Edge of centre,coner  on VCP 
VCP r 
0,1m from the right of the EUT 
Edge of centre,coner  on VCP 
VCP l 
0,1m from the left of the EUT 
Edge of centre,coner  on VCP 
 
14.5 Additions, Deviations and Exclusions from Standards 
 None
 
 
 
Report No. JSH006110139-001 
Page 61 of 94  
 
15. Electric Fast Transient/Burst Immunity Test 
 
Test result 
PASS 
 
15.1 Severity Level and Performance Criterion 
15.1.1 Test level 
 
Open circuit output  test voltage(+/-10%) and repetition rate of the impulses (+/- 20%) 
 
On power supply port PE 
On I/O (input & output) signal, 
data and control ports 
 
Level 
Voltage peak 
kV 
Repetition rate 
kHz 
Voltage peak 
kV 
Repetition rate 
 kHz 
1  0.5  5 0.25 5 
0.5 5 
3  2 5 1 5 
4 4 
2.5 
2 5 
  X 
Special 
Special 
Special 
Special 
 
Notes : 1. “X” is a an open level. The level has to be specified in the dedicated  equipment specification. 
            2. The gray rows were the selected test level. 
 
 
 
15.1.2 Performance Criterion  
 
 
   Performance 
criterion 
B 
 
 
Report No. JSH006110139-001 
Page 62 of 94  
 
15.2 Block Diagram of Test Setup 
 
 
 
 
15.2 .1Test Setup and Test Procedure 
 
 
Table top EUT 
 
The EUT was placed on a 0.8m high wooded table, standing on the ground reference  
plane 2.6m by 1.8m in size, made by aluminium 0.5mm thick. 
 
The distance between the EUT and any other of the metallic surface except the GRP is  
greater than 0.5m. 
 
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated  
at a distance of 0.1m above the ground reference plane to insure the distance between the  
coupling device and the EUT were 1m or less. 
 
The EUT was arranged and connected to satisfy its functional requirement and supplied by  
The coupling-decoupling network (Best EMC). 
 
 
Floor Standing EUT 
 
The EUT was placed on a 0.1m high wooden support, standing on the ground reference 
plane 2.6m by 1.8m, made by aluminium 0.5mm thick. 
 
The distance between the EUT and any other of the metallic surface except the GRP is  
greater than 0.5m. 
 
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated  
at a distance of 0.1m above the ground reference plane to insure the distance between the  
coupling device and the EUT were 1m or less. 
 
The EUT was arranged and connected to satisfy its functional requirement and supplied by  
The coupling-decoupling network (Best EMC). 
 
Best EMC 
 
     
EUT 
GRP 
 
 
Report No. JSH006110139-001 
Page 63 of 94  
 
15.2.2 Photo for test set-up 
        
none 
 
15.3 Test Protocol 
 
Temperature  : 
23
°C  
Relative Humidity: 
34% 
 
Test No. 
Level 
[kV] 
Polarity 
+/- 
Line for test 
Pass/ 
Fail 
Comment 
1 1 +/- L P   
2 1 +/- N P   
3 1 +/- 
PE 
NA  
4 1 +/- 
L-N 
P   
5 1 +/- 
L-PE 
NA  
6 1 +/- 
N-PE 
NA  
7 1 +/- 
L,N.PE 
NA  
8 0.5 +/- DC -   
9 0.5 +/- I/O -   
 
 
 
 
15.4 Additions, Deviations and Exclusions from Standards 
 
 
None. 
Page of 95
Display

Click on the first or last page to see other CINEMA SOUND 3 (serv.man2) service manuals if exist.