DOWNLOAD JBL AUTHENTICS L8 (serv.man2) Service Manual ↓ Size: 3.3 MB | Pages: 42 in PDF or view online for FREE

Model
AUTHENTICS L8 (serv.man2)
Pages
42
Size
3.3 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
authentics-l8-sm2.pdf
Date

JBL AUTHENTICS L8 (serv.man2) EMC - CB Certificate ▷ View online

Report No.: EM201300650-1                         Application No.: ZJ00032008                       Page 5 of 42 
 
 
2. GENERAL DESCRIPTION OF EUT 
2.1 APPLICANT 
Name: 
Harman International Industries, Incorporated 
Address: 
2.2 MANUFACTURER 
Name: 
Harman International Industries, Incorporated     
Address: 
2.3 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST  
Equipment: 
Active speaker system with wireless streaming 
Model: 
AUTHENTICS L16
 
Adding Model: 
AUTHENTICS L8 
Trade Name: 
JBL 
Power supply 
AC 100-240V,50/60Hz 
Frequency 
Range: 
2412MHz~2472MHz: 802.11b; 802.11g;  
Modulation type:  802.11b:DSSS  
802.11g:OFDM  
Channel space: 
5MHz  
Antenna type: 
PCB antenna  
Antenna gain: 
3.80~4.20dBi 
Note: 
Pretest the two antenna port (con1 and con2). Found that con1 is worst and 
the antenna of this port is 3.80~4.20dBi. So we record con1 port data.  
2.4 TEST OPERATION MODES 
Test mode: 
TX mode: EUT continue transmitting in lowest, middle and highest channels. 
RX mode: EUT is receiving in middle channels. 
2.5 LOCAL SUPPORTIVE INSTRUMENTS 
Name of Equipment 
Manufacturer 
Model 
Serial Number 
Notebook Lenovo 
E46A 
EB24320428 
 
Report No.: EM201300650-1                         Application No.: ZJ00032008                       Page 6 of 42 
 
 
3. LABORATORY AND ACCREDITATIONS  
3.1 LABORATORY 
The tests and measurements refer to this report were performed by EMC Laboratory of 
Guangzhou GRG Metrology and Test CO., LTD. 
         Add. 
  :    163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China 
         Telephone:   +86-20-38699959, 38699960, 38699961 
Fax 
  :   +86-20-38695185 
3.2 ACCREDITATIONS 
Our laboratories are accredited and approved by the following approval agencies according to 
ISO/IEC 17025. 
USA 
FCC Listed Lab (No. 688188) 
China 
CNAS (No.L0446) 
China 
DILAC (No.DL175) 
Canada 
Registration No.:8355A-1 
3.3 MEASUREMENT UNCERTAINTY 
Measurement 
Frequency 
Uncertainty 
Radiated 
Emission 
Horizontal 
30MHz~1000MHz 
4.2dB 
1GHz~12.75GHz 
4.2dB 
Vertical 
30MHz~1000MHz 
4.4dB 
1GHz~12.75GHz 
4.4dB 
This uncertainty represents an expanded uncertainty factor of k =2. 
 
 
Report No.: EM201300650-1                         Application No.: ZJ00032008                       Page 7 of 42 
 
 
3.4 LIST OF USED TEST EQUIPMENT AT GRGT 
Name of Equipment 
Manufacturer 
Model 
Serial 
Number 
Calibration 
Due 
Maximum transmit power 
Power meter 
Agilent 
N1914 
MY53160018  2014-07-25 
Power sensor 
Agilent 
E9034 
MY53100025  2014-07-25 
Temperature& 
humidity chamber 
CEPREI CEEC-MSJ-60BE 11015 
2014-05-21 
AC power supply 
WEST WE-1120 
681598 
2014-05-31 
Shielding room 
ETS 
RFD_100 
3728 
2014-03-25 
Frequency Range 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Temperature& 
humidity chamber 
ETOMN NTH1000-40A 
08100012 
2014-05-21 
AC power supply 
WEST WE-1120 
681598 
2014-05-31 
Dwell Time 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Hopping channel separation 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Hopping sequence 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Spurious Emission from Tx/ Rx 
Biconical 
Log-periodic Antenna 
ETS.LINDGREN 3142C 
00075971 
2014-05-26 
Signal Generator 
R&S 
SML03 
103002 
2013-11-13 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Biconical antenna 
ELECTRO-METRICS BIA-30S 
166 
2014-05-26 
log-periodical antenna  ELECTRO-METRICS LPA-30 
383 
2014-05-26 
Horn antenna 
ETS.LINDGREN 
3117 
00075824 
2014-08-19 
Horn antenna 
SCHWARZBECK BBHA9120D D752 
2013-10-14 
Temperature and 
Humidity box 
CEPREI CEEC-MSJ-60BE 11015 
2014-05-21 
AC power supply 
WEST WE-1120 
681598 
2014-05-31 
 
Report No.: EM201300650-1                         Application No.: ZJ00032008                       Page 8 of 42 
 
 
4. RADIO TECHNICAL REQUIREMENTS SPECIFICATION 
4.1 MAXIMUM TRANSMIT POWER 
4.1.1  LIMITS 
Frequency 
EN300 328 clause 4.3.1 
2400MHz~2483.5 MHz 
20 dBm (i.e. 100mW) 
4.1.2  TEST METHOD 
EUT operation status: 
Keep EUT on transmitting mode by the software provided by 
manufacturer. 
Pretest the EUT at different transmission rate and report show 
the worst case data. 
     
Test channel: 
802.11b/g: 
Lowest channel: (2412MHz),Middle channel: (2442MHz), 
Highest channel: (2472MHz) 
Test condition: 
Normal and extreme test conditions. 
Test equipment used: 
Refer to section 3.4 
Test procedure: 
As 5.7.2.2 and annex C1 of standard EN 300328 
Remark:    
Pre-scan all the rate, found that:  
11Mbps of rate is the worst case of 802.11b;  
54Mbps of rate is the worst case of 802.11g ; 
 
4.1.3  TEST SETUP 
 
 
 
Attenuator 
 EUT     
Antenna 
connector  
Receiver 
Page of 42
Display