4 T E S T E N V I R O N M E N T
4.1
Address of the test laboratory
MIKES BABT Product Service GmbH
Ohmstrasse
2-4
D - 94342 Strasskirchen
4.2 Environmental
conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:
15-35 ° C
Humidity: 30-60
%
Atmospheric pressure:
86-106 kPa
4.3
Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated
for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit
modelling – Uncertainty in EMC measurements“ and is documented in the MIKES BABT Product Service GmbH
quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar
to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.
File No.
F24268-01-00HM
, page 9 of 26
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5 T E S T C O N D I T I O N S A N D R E S U L T S
5.1 Conducted
disturbance
For test instruments and accessories used see section 6 Part A 4.
5.1.1
Description of the test location
Test location:
Shielded room no. 2
5.1.2
Photo documentation of the test set-up
5.1.3 Test
result
Frequency range:
0.15 MHz - 30 MHz
Min. limit margin
>5 dB at 0.15 - 30 MHz
The requirements are FULFILLED.
Remarks:
For detailed results, please see the following page(s).
Only the worst results are shown, even all tests have been done.
File
No.
F24268-01-00HM
, page 10 of 26
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.1.4 Test
protocol
Test point
L1
Operation mode:
60 Hz 1/8 power
Remarks: n/a
Result: passed
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
165
34,5
30,7 no Result
200
29,7
33,9
240
23,6
38,5
19070
5,8
54,2
27460
6,3
53,7
dB [µV]
PK:
AV:
QP:
♦
AV:
×
0.15
1
10
20
30 [MHz]
Detector:
Legend
QP LIMIT
AV LIMIT
0
10
20
30
40
50
60
70
80
File
No.
F24268-01-00HM
, page 11 of 26
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
Test point:
N
Operation mode:
60 Hz 1/8 power
Remarks: n/a
Result: passed
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
165
32,9
32,3 no Result
200
31,2
32,4
235
23,7
38,6
27645
22,9
37,1
dB [µV]
PK:
AV:
QP:
♦
AV:
×
0.15
1
10
20
30 [MHz]
Detector:
Legend
QP LIMIT
AV LIMIT
0
10
20
30
40
50
60
70
80