DOWNLOAD Harman Kardon SUB-TS 8 (serv.man2) Service Manual ↓ Size: 2.19 MB | Pages: 37 in PDF or view online for FREE

Model
SUB-TS 8 (serv.man2)
Pages
37
Size
2.19 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-ts-8-sm2.pdf
Date

Harman Kardon SUB-TS 8 (serv.man2) EMC - CB Certificate ▷ View online

 
 
File No. 
F24268-01-00HM
, page 8 of 26 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
4   T E S T  E N V I R O N M E N T  
4.1 
Address of the test laboratory 
 
 
MIKES BABT Product Service GmbH 
 Ohmstrasse 
2-4 
 
D - 94342 Strasskirchen 
 
 
 
 
4.2 Environmental 
conditions 
 
During the measurement the environmental conditions were within the listed ranges: 
 
Temperature: 
15-35 ° C 
 
 
 
 
Humidity: 30-60 
 
 
 
 
Atmospheric pressure: 
86-106 kPa 
 
 
 
 
4.3 
Statement of the measurement uncertainty 
 
The data and results referenced in this document are true and accurate. The reader is cautioned that there may 
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated 
for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit 
modelling – Uncertainty in EMC measurements“ and is documented in the MIKES BABT Product Service GmbH 
quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar 
to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued 
compliance of the device. 
 
 
 
 
File No. 
F24268-01-00HM
, page 9 of 26 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5   T E S T   C O N D I T I O N S   A N D   R E S U L T S  
5.1 Conducted 
disturbance 
For test instruments and accessories used see section 6 Part A 4
5.1.1 
Description of the test location 
 
Test location: 
Shielded room no. 2 
 
5.1.2 
Photo documentation of the test set-up 
 
 
 
5.1.3 Test 
result 
 
Frequency range: 
0.15 MHz - 30 MHz 
 
Min. limit margin 
>5 dB at 0.15 - 30 MHz 
 
The requirements are FULFILLED. 
 
Remarks: 
For detailed results, please see the following page(s).  
 
 
Only the worst results are shown, even all tests have been done.  
 
 
 
 
 
 
 
 File 
No. 
F24268-01-00HM
, page 10 of 26 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.1.4 Test 
protocol 
 
Test point  
L1 
Operation mode: 
60 Hz 1/8 power 
Remarks: n/a 
Result: passed 
 
 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
165
34,5
30,7 no Result
200
29,7
33,9
240
23,6
38,5
19070
5,8
54,2
27460
6,3
53,7
dB [µV]
PK: 
AV:
QP:
 
AV: 
×
 0.15
1
10
20
30  [MHz]
 Detector:
Legend 
QP  LIMIT
AV   LIMIT
0
10
20
30
40
50
60
70
80
  
 
 File 
No. 
F24268-01-00HM
, page 11 of 26 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
 
 
Test point:  
Operation mode: 
60 Hz 1/8 power 
Remarks: n/a 
Result: passed 
 
 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
165
32,9
32,3 no Result
200
31,2
32,4
235
23,7
38,6
27645
22,9
37,1
dB [µV]
PK: 
AV:
QP:
 
AV: 
×
 0.15
1
10
20
30  [MHz]
 Detector:
Legend 
QP  LIMIT
AV   LIMIT
0
10
20
30
40
50
60
70
80
  
Page of 37
Display

Click on the first or last page to see other SUB-TS 8 (serv.man2) service manuals if exist.