Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-ts-8-sm2.pdf
Date

Harman Kardon SUB-TS 8 (serv.man2) EMC - CB Certificate ▷ View online

 
 File 
No. 
F24268-01-00HM
, page 12 of 26 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.2 
 Disturbance power 
For test instruments and accessories used see section 6 Part A 7
5.2.1 
Description of the test location 
 
Test location: 
Shielded room no. 7 
 
5.2.2 
Photo documentation of the test set-up 
 
 
 
5.2.3 Test 
result 
 
Frequency range: 
30 MHz - 300 MHz 
 
Min. limit margin 
>5 dB at 30 - 300 MHz 
 
The requirements are FULFILLED. 
 
Remarks: 
For detailed results, please see the following page(s).  
 
 
 
 
 
 
 
 
 
 
 File 
No. 
F24268-01-00HM
, page 13 of 26 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.2.4 Test 
protocol 
 
Test point:  
All cables 
Operation mode: 
60 Hz 1/8 power 
Remarks: n/a 
Result: passed 
 
 
30-300
<25
<25
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading 
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading 
AV
[dBpW]
Limit QP
[dBpW]
 
 
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP  dBpW
Power AV  dBpW
QP
AV
<25dBpW
 
 
 File 
No. 
F24268-01-00HM
, page 14 of 26 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.3 Harmonic 
current 
For test instruments and accessories used see section 6 Part H & Fl
5.3.1 
Description of the test location 
 
Test location: 
Test location no. 1 
 
5.3.2 
Photo documentation of the test set-up 
 
 
 
5.3.3 Test 
result 
 
The requirements are FULFILLED. 
 
Remarks: 
For detailed results, please see the following page(s).  
 
 
 
 
 
 
 
 
 
 
 File 
No. 
F24268-01-00HM
, page 15 of 26 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.3.4 Test 
protocol 
 
Operation mode: 
Pink noise 1/8 power 
Remarks: n/a 
Result: passed 
 
 
Maximum RMS current and corresponding values in timewindow 165:
Voltage:
Current:
Power:
Powerfactor:
Testconditions:
230.35 Vrms
0.342 Arms
56.1 W
0.711
EN 61000-3-2 / A14, f=50 Hz, Phase=L1, Range=0.80 A
Time window cycles=16, Grouping of harmonics=off
P1=56.2 W
CosPhi1: 0.963
THD=0.01 %
THD=87.48 %
78.9 VA
THV=0.015 V
THC=0.224 A
POHV=0.002 V
POHC=0.006 A
PWHD=0.01 %
PWHD=21.37 %
Entire measurement (2.5 min = 469 time windows)
Worst 2.5 min
Average
P
A
S
S
F
A
I
L
Ha
Maximum Window EN61000-3-2
 Class A
Margin
in MaxWin
100 to
150%
Ex-
ceeded
100 to
150%
Ex-
ceeded
Value
Ex-
ceeded
DC
0.0074 A
129
-.- - - -
- - - . -
0
0
n.e.
n.e. -0.0001 A
0 X
1
0.2533 A
165
-.- - - -
- - - . -
0
0
n.e.
n.e. 0.2369 A
0 X
2
0.0061 A
128
1.0800 A
-99.4 %
0
0
n.e.
n.e. 0.0033 A
0 X
3
0.1680 A
165
2.3000 A
-92.7 %
0
0
n.e.
n.e. 0.1549 A
0 X
4
0.0036 A
1
0.4300 A
-99.2 %
0
0
n.e.
n.e. 0.0022 A
0 X
5
0.1295 A
165
1.1400 A
-88.6 %
0
0
n.e.
n.e. 0.1219 A
0 X
6
0.0025 A
1
0.3000 A
-99.2 %
0
0
n.e.
n.e. 0.0016 A
0 X
7
0.0659 A
159
0.7700 A
-91.4 %
0
0
n.e.
n.e. 0.0636 A
0 X
8
0.0016 A
1
0.2300 A
-99.3 %
0
0
n.e.
n.e. 0.0010 A
0 X
9
0.0256 A
433
0.4000 A
-93.6 %
0
0
n.e.
n.e. 0.0249 A
0 X
10
0.0013 A
1
0.1840 A
-99.3 %
0
0
n.e.
n.e. 0.0007 A
0 X
11
0.0103 A
165
0.3300 A
-96.9 %
0
0
n.e.
n.e. 0.0092 A
0 X
12
0.0013 A
1
0.1533 A
-99.2 %
0
0
n.e.
n.e. 0.0006 A
0 X
13
0.0137 A
165
0.2100 A
-93.5 %
0
0
n.e.
n.e. 0.0128 A
0 X
14
0.0008 A
241
0.1314 A
-99.4 %
0
0
n.e.
n.e. 0.0004 A
0 X
15
0.0093 A
433
0.1500 A
-93.8 %
0
0
n.e.
n.e. 0.0089 A
0 X
16
0.0005 A
241
0.1150 A
-99.5 %
0
0
n.e.
n.e. 0.0003 A
0 X
17
0.0043 A
361
0.1324 A
-96.7 %
0
0
n.e.
n.e. 0.0041 A
0 X
18
0.0006 A
1
0.1022 A
-99.4 %
0
0
n.e.
n.e. 0.0003 A
0 X
19
0.0049 A
165
0.1184 A
-95.9 %
0
0
n.e.
n.e. 0.0044 A
0 X
20
0.0005 A
1
0.0920 A
-99.5 %
0
0
n.e.
n.e. 0.0002 A
0 X
21
0.0043 A
357
0.1071 A
-96.0 %
0
0
n.e.
n.e. 0.0041 A
0 X
22
0.0003 A
426
0.0836 A
-99.6 %
0
0
n.e.
n.e. 0.0002 A
0 X
23
0.0027 A
361
0.0978 A
-97.3 %
0
0
n.e.
n.e. 0.0025 A
0 X
24
0.0004 A
1
0.0767 A
-99.4 %
0
0
n.e.
n.e. 0.0002 A
0 X
25
0.0023 A
165
0.0900 A
-97.5 %
0
0
n.e.
n.e. 0.0020 A
0 X
26
0.0005 A
1
0.0708 A
-99.3 %
0
0
n.e.
n.e. 0.0002 A
0 X
27
0.0022 A
370
0.0833 A
-97.4 %
0
0
n.e.
n.e. 0.0020 A
0 X
28
0.0004 A
1
0.0657 A
-99.4 %
0
0
n.e.
n.e. 0.0002 A
0 X
29
0.0017 A
359
0.0776 A
-97.9 %
0
0
n.e.
n.e. 0.0015 A
0 X
30
0.0004 A
1
0.0613 A
-99.3 %
0
0
n.e.
n.e. 0.0002 A
0 X
31
0.0013 A
370
0.0726 A
-98.2 %
0
0
n.e.
n.e. 0.0012 A
0 X
32
0.0004 A
1
0.0575 A
-99.2 %
0
0
n.e.
n.e. 0.0001 A
0 X
33
0.0013 A
370
0.0682 A
-98.1 %
0
0
n.e.
n.e. 0.0012 A
0 X
34
0.0003 A
1
0.0541 A
-99.4 %
0
0
n.e.
n.e. 0.0001 A
0 X
35
0.0011 A
357
0.0643 A
-98.4 %
0
0
n.e.
n.e. 0.0009 A
0 X
36
0.0002 A
271
0.0511 A
-99.6 %
0
0
n.e.
n.e. 0.0001 A
0 X
37
0.0008 A
370
0.0608 A
-98.6 %
0
0
n.e.
n.e. 0.0007 A
0 X
38
0.0002 A
1
0.0484 A
-99.6 %
0
0
n.e.
n.e. 0.0001 A
0 X
39
0.0008 A
370
0.0577 A
-98.6 %
0
0
n.e.
n.e. 0.0007 A
0 X
40
0.0001 A
270
0.0460 A
-99.7 %
0
0
n.e.
n.e. 0.0001 A
0 X
HARMONIC ANALYSIS: Test PASS