DOWNLOAD Harman Kardon SUB-TS 8 (serv.man2) Service Manual ↓ Size: 2.19 MB | Pages: 37 in PDF or view online for FREE

Model
SUB-TS 8 (serv.man2)
Pages
37
Size
2.19 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-ts-8-sm2.pdf
Date

Harman Kardon SUB-TS 8 (serv.man2) EMC - CB Certificate ▷ View online

 
Immunity conducted voltages (S2)
Manufa./Impo.  :  Harman Consumer
Model  :  SUB-TS7/230
E.U.T  :  Subwoofer
Serial-No.  :  PP001
________________________________________________________________________________________
Report No.  :  F 24268
Page 6 of 10
[dB(µV)]
80
90
100
110
120
130
[MHz]
0,3
1
3
10
30
100
0.15
150
Test point (injection into) :  LINE
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker Woofer
Output : 43 mW/8 Ohm
Channel : left
Margin : 6 dB
 
Test Engineer : M. Hackl
Date : 05.08.2004
Place : Immunity Site 1
 
 
 
Immunity conducted voltages (S2)
Manufa./Impo.  :  Harman Consumer
Model  :  SUB-TS7/230
E.U.T  :  Subwoofer
Serial-No.  :  PP001
________________________________________________________________________________________
Report No.  :  F 24268
Page 7 of 10
[dB(µV)]
90
100
110
120
130
140
 0,15 
[MHz]
20
40
60
80
100
120
140
 150 
Test point (injection into) :  MAINS
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker Woofer
Output : 54 mW/8 Ohm
Channel : left
Margin : 6 dB
 
Test Engineer : M. Hackl
Date : 05.08.2004
Place : Immunity Site 1
 
 
Frequency       Level           Limit      Margin 
  [MHz]       [dB(µV)]      [dB(µV)]     [dB] 
28,0
133,0
130,0
3,0
28,5
131,0
130,0
1,0
29,0
130,0
130,0
0,0
29,2
130,0
130,0
0,0
29,4
130,0
130,0
0,0
29,6
130,0
130,0
0,0
29,8
130,0
130,0
0,0
30,0
130,0
130,0
0,0
 
Immunity conducted voltages (S2)
Manufa./Impo.  :  Harman Consumer
Model  :  SUB-TS7/230
E.U.T  :  Subwoofer
Serial-No.  :  PP001
________________________________________________________________________________________
Report No.  :  F 24268
Page 8 of 10
[dB(µV)]
80
90
100
110
120
130
[MHz]
0,3
1
3
10
30
100
0.15
150
Test point (injection into) :  SUB
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 56 dB
Monitoring : Speaker Woofer
Output : 45 mW/8 Ohm
Channel : left
Margin : 6 dB
 
Test Engineer : M. Hackl
Date : 05.08.2004
Place : Immunity Site 1
 
 
 
Immunity radiated fields (S3)
Manufa./Impo.  :  Harman Consumer
Model  :  SUB-TS7/230
E.U.T  :  Subwoofer
Serial-No.  :  PP001
________________________________________________________________________________________
Report No.  :  F 24268
Page 9 of 10
Measurement Protocol
 
Mode
Channel
Monitoring
Check
S/N
Result
LINE
left
Speaker Woofer
Sound
 58 
DATA!
Test Engineer : M. Hackl
Date : 12.08.2004
Place : Immunity Site 1
The above mentioned list shows all measurements performend on the EUT for immunity from
radiated fields.
If Result -- DATA! -- then more details on next pages.
If Result -- >x dB o.L. -- then all Results more x dB over Limit
Page of 37
Display

Click on the first or last page to see other SUB-TS 8 (serv.man2) service manuals if exist.