6.7 ELECTROSTATIC DISCHARGE
st Sp
rd:
IEC 61000-4-2
6.7.1 Te
ecification
Basic Standa
Discharge Impedance:
330 ohm / 150 pF
Discharge Voltage:
Air Discharge:2kV/4kV/8 Kv (Direct)
Contact Discharge:2kV/4kV (Direct/Indirect)
Contact Discharge:2kV/4kV (Direct/Indirect)
Polarity:
Positive & Negative
Number of Discharge:
Air Discharge: min. 10 times at each test point
Contact Discharge: min. 25 times at each test point
Contact Discharge: min. 25 times at each test point
Discharge Mode:
Single Discharge
Discharge Period:
1 second minimum
6.7.2 Test Procedure
he test generator necessary to perform direct and indirect application of discharges
the EUT in the following manner:
. Contact discharge was applied to conductive surfaces and coupling planes of the
UT.
t
th single discharges. For the single discharge
suc
le discharges was at least 1 second. The EUT shall be
to a
discharges, 100 each at negative and positive polarity, at a
st points shall be subjected to at least 50
er of the front edge of the horizontal coupling plane.
receive at least 50 direct contact
discharges.
If no direct contact test points are available, then at least 200 indirect discharges
shall be applied in the indirect mode. Test shall be performed at a maximum
repetition rate of one discharge per second.
The selected point, which was performed with electrostatic discharge, please
refers to the “Photo(s) shown the location(s) of ESD evaluated”.
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and
positioned at a distance 0.1m from, the EUT, with the Discharge Electrode
touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned
vertically at a distance of 0.1m from the EUT, with the Discharge Electrode
touching the coupling plane. The four faces of the EUT will be performed with
electrostatic discharge.
If no direct contact test points are available, then at least 200 indirect discharges
shall be applied in the indirect mode. Test shall be performed at a maximum
repetition rate of one discharge per second.
The selected point, which was performed with electrostatic discharge, please
refers to the “Photo(s) shown the location(s) of ESD evaluated”.
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and
positioned at a distance 0.1m from, the EUT, with the Discharge Electrode
touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned
vertically at a distance of 0.1m from the EUT, with the Discharge Electrode
touching the coupling plane. The four faces of the EUT will be performed with
electrostatic discharge.
b. Air discharges at insulation surfaces of the EUT.
It was at least ten single discharges with positive and negative at the same selected
point.
point.
c. For the actual test configuration, please refer to the related Item –EUT Test Photos.
T
to
a
E
to
a
E
During the est, it was performed wi
time
between
time
between
cessive sing
exposed
minimum of four test points. One of the te
minimum of four test points. One of the te
t least 200
indirect discharges to the cent
The remaining three test points shall each
The remaining three test points shall each
Report No:W-N-1109009-CY-01-1
Telecom Technology Center
6.7.3 Deviation From Test Standard
p
No deviation
6.7.4 Test Setu
e:
Not
TA
The
standing on the
Ground Reference Plane. The GRP consisted of a sheet of aluminum at least 0.25mm
thic
thic
tem. A
Hor
to the
GR
40k total impedance. The equipment under test, was
inst
, and its
cables were placed on the HCP and isolated by an insulating support of 0.5mm
thic
thic
wal
FLO
The equipment under test was installed in a representative system as described in
FLO
The equipment under test was installed in a representative system as described in
lated from the Ground Reference
Pla
of a
of a
m that is at least 0.25mm thick, and 2.5meters square connected to the
sides.
BLE-TOP EQUIPMENT
configuration consisted of a wooden table 0.8 meters high
k, and 2.5 meters square connected to the protective grounding sys
izontal Coupling Plane (1.6m x 0.8m) was placed on the table and attached
P by means of a cable with 9
alled in a representative system as described in section 7 of IEC 61000-4-2
kness. A distance of1-meter minimum was provided between the EUT and the
ls of the laboratory and any other metallic structure.
OR-STANDING EQUIPMENT
section 7 of IEC 61000-4-2, and its cables were iso
ne by an insulating support of 0.1-meter thickness. The GRP consisted of a sheet
luminu
protective grounding system and extended at least 0.5 meters from the EUT on all
38
Report No:W-N-1109009-CY-01-1
Telecom Technology Center
Note: (1) P/N denotes the Positive/Negative polarity of the output voltage.
(2) Test condition: Direct / Indirect (HCP/VCP) discharges: Minimum 25 times
itive/Negative) at each point. Air discharges: Minimum 10 times
(Positive/Negative) at each point.
n(s) in which discharge (Air and contact discharge) to be applied
y photos shown in next page(s)
(4) The Indirect (HCP/VCP) discharges description of test point as
following:1.left side 2.right side 3.front side 4.rear side
(5) N/A - denotes test is not applicable in this test report
(6) Criteria A: There was no change operated with initial operating during the
(6) Criteria A: There was no change operated with initial operating during the
test.
(7) Criteria B: The EUT function loss during the test, but self-recoverable after
the test.
(8) Criteria C: The system shut down during the test.
(9) The test was performed in ESD Room.
(9) The test was performed in ESD Room.
(Pos
(3) Test locatio
illustrated b
39
Report No:W-N-1109009-CY-01-1
Telecom Technology Center
6.7.5 Test Photographs
Red arrow mark for Air Discharge and Blue arrow mark for Contact Discharge