DOWNLOAD Harman Kardon MAS 101-102-111 (serv.man5) Service Manual ↓ Size: 1.38 MB | Pages: 73 in PDF or view online for FREE

Model
MAS 101-102-111 (serv.man5)
Pages
73
Size
1.38 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
mas-101-102-111-sm5.pdf
Date

Harman Kardon MAS 101-102-111 (serv.man5) EMC - CB Certificate ▷ View online

Date: 2010-09-27 
 
Page 67 of 71 
No.:  MH184556 
 
 
   
 
Severity Levels for Electrostatic Discharge: 
Level 
Test Voltage 
Test Voltage 
 
Direct & Indirect Contact 
Discharge 
Air Discharge 
 
 
 
±
2kV 
±
2kV 
±
4kV 
±
4kV 
±
6kV 
±
8kV 
±
8kV 
±
15kV 
 
 
Results: 
Pass 
Please refer to the following table for individual details 
 
 
Individual Results 
Location 
Discharge Method 
Test Voltage 
Pass 
Failed 
HCP 
[Horizontal Coupling 
Plane] 
Indirect Contact 
±
4kV 
 
 
VCP 
[Vertical Coupling Plane] 
Indirect Contact 
±
4kV 
 
 
Enclosure 
Direct Contact 
±
4kV 
 
 
30 Metal screws 
Direct Contact 
±
4kV 
 
 
 
 
Remark:   
Calculated measurement uncertainty: 0.4kV 
    . 
Date: 2010-09-27 
 
Page 68 of 71 
No.:  MH184556 
 
 
   
 
3.2.8 
Radiated Immunity Keyed Carrier [900 MHz] 
 
Test Requirement: 
EN 55020 
 
Test Method: 
IEC 61000-4-3 
 
Severity: 
3V/m 
 
Modulation: 
Duty cycle 1/8, 217Hz repetition frequency 
 
 
 
Performance Criterion Requirement: 
 
 
 
Temperature: 
20.0 
o
 
Humidity: 
58.0 % 
 
Atmospheric Pressure: 
101.0kPa 
 
 
 
 
Test Date(s): 
2009-07-02 
 
 
 
 
Mode of Operation: 
FM, AUX, CD, LINE IN, PHONO IN,   
TV IN 
 
 
Test Method: 
The test was performed in accordance with IEC 61000-4-3. 
 
 
Test Setup: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
distance = 3m 
EUT 
Amplifier 
Signal Generator 
Computer 
Absorbers 
Date: 2010-09-27 
 
Page 69 of 71 
No.:  MH184556 
 
 
   
 
Severity Levels for Radiated Immunity: 
Level 
Field Strength 
 
[V/m] 
10 
 
 
Results: 
Pass 
Please refer to the following table for individual details 
 
 
Frequency 
Face 
Polarity 
Level 
Individual Results 
(MHz) 
 
 
(V/m) 
Pass 
Failed 
900   
0
Horizontal 
 
 
900   
90
Horizontal 
 
 
900   
180
Horizontal 
 
 
900   
270
Horizontal 
 
 
 
 
 
 
 
 
900   
0
Vertical 
 
 
900   
90
Vertical 
 
 
900   
180
Vertical 
 
 
900   
270
Vertical 
 
 
 
 
Remark: 
Calculated measurement uncertainty: -1.3V/m (Negative Value), +3.7V/m (Positive Value) 
 
Date: 2010-09-27 
 
Page 70 of 71 
No.:  MH184556 
 
 
   
 
3.2.9 
Electrical Fast Transients on AC Supply 
 
Test Requirement: 
EN 55020 
 
Test Method: 
IEC 61000-4-4 
 
Severity: 
Level 2 on AC[
±
1kV] 
 
 
 
Performance Criterion Requirement: 
 
 
 
Temperature: 
20.0 
o
 
Humidity: 
58.0 % 
 
Atmospheric Pressure: 
101.0 kPa 
 
 
 
 
Test Date(s): 
2009-07-06 
 
 
 
 
Mode of Operation: 
All modes 
Test Method: 
The test was performed in accordance with IEC 61000-4-4. 
 
 
Test Setup: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Burst Generator 
EUT 
    0.1m 
10cm height stand 
EUT 
Capacitive 
Coupling Clamp 
Signal Cable 
Mains Cable 
Page of 73
Display