Harman Kardon MAS 101-102-111 (serv.man5) EMC - CB Certificate ▷ View online
Date: 2010-09-27
Page 47 of 71
No.: MH184556
3.1.6
Harmonics Emissions on AC Supply
Test Requirement:
EN 61000-3-2
Test Method:
EN 61000-3-2
Level:
Class A
Test Date(s):
2009-07-03
Mode of Operation:
All Modes
Input Voltage:
230Va.c.
Test Method:
The test was performed in accordance with EN 61000-3-2.
Date: 2010-09-27
Page 48 of 71
No.: MH184556
Results and limit line for Harmonics Emissions:
For limits for Harmonics Emission Test, please refer to limit lines (saw-tooth lines) in the following
diagram.
diagram.
Results:
Pass
Please refer to the following table for individual results.
Remark:
Calculated measurement uncertainty: 6.8%
Date: 2010-09-27
Page 49 of 71
No.: MH184556
3.1.6
Emission for Fluctuations & Flicker
Test Requirement:
EN 61000-3-3
Test Method:
EN 61000-3-3
Level:
N/A
Test Date(s):
2009-07-03
Mode of Operation:
All Modes
Test Method:
The test was performed in accordance with EN 61000-3-3.
Date: 2010-09-27
Page 50 of 71
No.: MH184556
Limits for Flicker:
Please refer to the result table for details.
Results:
Pass
Please refer to the following table for individual results.
Maximum Occurring Levels:
Pst:
0.028
Limit =
1.0
(The Highest Short Term Flicker Value)
Plt:
0.028
Limit =
0.65
(The Highest Long Term Flicker Value)
dc(%):
0.006
Limit =
3.3% (The Highest Relative Steady State Voltage Change (1sec))
dmax(%):
0.080
Limit =
4%
(*The Highest Maximum Relative Voltage Change)
Tdt:
0.0
Limit =
500ms
(The Max Time (in milli-sec) that dt exceeds 3.3%)
Ut(V):
230V
(EUT Test RMS Voltage)
Remarks:
* - Some products may have more relax limits (refer to Clause 5 of EN 61000-3-3)
Calculated measurement uncertainty: ±8.0%
* - Some products may have more relax limits (refer to Clause 5 of EN 61000-3-3)
Calculated measurement uncertainty: ±8.0%
Click on the first or last page to see other MAS 101-102-111 (serv.man5) service manuals if exist.