DOWNLOAD Harman Kardon MAS 101-102-111 (serv.man5) Service Manual ↓ Size: 1.38 MB | Pages: 73 in PDF or view online for FREE

Model
MAS 101-102-111 (serv.man5)
Pages
73
Size
1.38 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
mas-101-102-111-sm5.pdf
Date

Harman Kardon MAS 101-102-111 (serv.man5) EMC - CB Certificate ▷ View online

Date: 2010-09-27 
 
Page 63 of 71 
No.:  MH184556 
 
 
   
 
Results for Immunity to Radiated Interference: 
 
Results: 
 
Sound:- 
 
Operating mode(s):- 
FM, AUX, CD, LINE IN, 
PHONO IN, TV IN 
Monitoring Port(s):- 
 
Speaker L 
Pass 
Speaker R 
Pass 
Headphone L 
Pass 
Headphone R 
Pass 
 
Remark(s):- 
n/a  - Not Applicable 
Date: 2010-09-27 
 
Page 64 of 71 
No.:  MH184556 
 
 
   
 
3.2.6 
Screening Effectiveness Coaxial Antenna Terminal 
 
Test Requirement: 
EN 55020 
 
Test Method: 
EN 55020 
 
Level: 
Table 8a 
 
 
 
Performance Criterion Requirement: 
 
 
 
Test Date(s): 
2009-07-02 
 
 
 
 
Mode of Operation: 
FM Mode 
 
 
Test Method: 
The test was performed in accordance with EN55020. 
 
 
Test Setup: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Date: 2010-09-27 
 
Page 65 of 71 
No.:  MH184556 
 
 
   
 
Table 8a – Limits of screening effectiveness of the coaxial antenna terminals 
Equipment 
Wanted signal 
frequency or channel 
MHz or N 
Unwanted signal 
frequency 
MHz 
Level 
dB 
FM sound receivers 
f
m
 
f
m
 
± 0.001 
 20
 
Television receivers 
Videotape equipment 
Middle channel of each 
TV band 
04, 08, 25, 55 
fv ± 1 
 50
 
a
 The middle frequency of the FM band 
b
 With built-in television broadcast receiving facility in the RF recording mode 
c
 For system L 
d
 Each one falls inside the wanted channel (f
v
 = wanted channel video carrier) 
 
 
Results: 
Pass 
Please refer to the following table for individual results. 
 
 
Frequency   
Level 
Limit 
[MHz] 
[dB] 
[dB] 
98.0 
29.8 
≥20.0 
 
 
Remark: 
Only long antenna cable (>6m) connected. 
 
Date: 2010-09-27 
 
Page 66 of 71 
No.:  MH184556 
 
 
   
 
3.2.7 
Electrostatic Discharge 
 
Test Requirement: 
EN 55020 
 
Test Method: 
IEC 61000-4-2 
 
Severity: 
±
4kV for Direct & Indirect Contact Discharge 
 
 
±
8kV for Air Discharge 
 
 
 
Performance Criterion Requirement: 
 
 
 
Temperature: 
20.0
o
 
Humidity: 
56.0 % 
 
Atmospheric Pressure: 
101.0 kPa 
 
 
 
 
Test Date(s): 
2009-07-06 
 
 
 
 
Mode of Operation: 
All modes 
 
 
Test Method: 
The test was performed in accordance with IEC 61000-4-2. 
 
 
Test Setup: 
 
 
Page of 73
Display