Harman Kardon HS 500 (serv.man3) EMC - CB Certificate ▷ View online
Page 8 of 59
Report No: JSH006020710-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
< 2 mm, no entering
N
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set control
N
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
< 5V
P
If C is not greater than 0,1 μF no test needed
> 0.2
μF
N
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
P
30 mm diameter test tool for 5 s (100 or 250 N) ... : 100N P
9.2
No hazard after removing a cover by hand
Can not be removed by hand
N
10 INSULATION
REQUIREMENTS
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
(See appended table)
P
10.2 Humidity
treatment 48 h or 120 h .......................... : 48h, 30
O
C, 93%R.H.
P
10.3
Insulation resistance and dielectric strength
(See appended table)
P
11 FAULT
CONDITIONS
P
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
(See appended table)
P
No hazard from softening solder
P
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(See appended table)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N
Page 9 of 59
Report No: JSH006020710-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than
2 cm²
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table)
P
12 MECHANICAL
STRENGTH
P
12.1.1
Bump test where mass >7 kg
5.3kg
N
12.1.2 Vibration
test
Not carried out, no connection
which might impair safety can
become loosen
which might impair safety can
become loosen
P
12.1.3
Impact hammer test
0.5J P
Steel ball test
2J P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
P
12.1.5
Thermoplastic enclosures strain relief test
70
o
C, 7h
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
P
12.5
Antenna coaxial sockets providing isolation
N
12.6
Telescoping or rod antennas construction
N
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
P
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
Page 10 of 59
Report No: JSH006020710-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
13.2
Determination of operating voltage
T501: pin13, 14, 15- pin 5, 6:
270Vrms, 500Vp
270Vrms, 500Vp
T502: pin3 - pin 15: 380Vrms,
580Vp
580Vp
P
13.3 Clearances
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: 4.0mm required
240Vrms) —accessible parts /
enclosure: 4.0mm required
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: 4.2mm
required
270Vrms, 500Vp) —accessible
parts / enclosure: 4.2mm
required
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: 5.1mm
required
380Vrms, 580Vp) —accessible
parts / enclosure: 5.1mm
required
Primary heat sink —accessible
parts / enclosure: 5.1mm
required
parts / enclosure: 5.1mm
required
L-N before fuse link:
2.0mm required
T501: P—S: 4.2mm required
T502: P—S: 5.1mm required
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
Measured distance:
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: >4.5mm
240Vrms) —accessible parts /
enclosure: >4.5mm
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
Primary heat sink —accessible
parts / enclosure: >10mm
parts / enclosure: >10mm
L-N before fuse link: 3.7mm
T501: P—S: >6.5mm
T502: P—S: >8.0mm
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N
Page 11 of 59
Report No: JSH006020710-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
13.4 Creepage
distances
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: 5.0mm required
240Vrms) —accessible parts /
enclosure: 5.0mm required
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: 5.6mm
required
270Vrms, 500Vp) —accessible
parts / enclosure: 5.6mm
required
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: 7.7mm
required
380Vrms, 580Vp) —accessible
parts / enclosure: 7.7mm
required
Primary heat sink —accessible
parts / enclosure: 7.7mm
required
parts / enclosure: 7.7mm
required
L-N before fuse link: 3.0mm
required
required
T501: P—S: 5.6mm required
T502: P—S: 7.7mm required
P
Creepage distances greater than table 11 minima Measured distance:
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: >5.5mm
240Vrms) —accessible parts /
enclosure: >5.5mm
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
Primary heat sink —accessible
parts / enclosure: >10mm
parts / enclosure: >10mm
L-N before fuse link: 3.7mm
T501: P—S: >6.5mm
T502: P—S: >8.0mm
P
13.5 Printed
boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N