Page 12 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
No such parts 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
No such parts 
 
14 COMPONENTS 
14.1 Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such components 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N 
 
b) Resistors separately approved .......................... :  
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes  
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y1: CY1, CY2, CY501, CY502 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2: C501, C502, C503 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such component 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
EC502 metal case 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
EC502 metal case 
 
Shielded by a barrier to V-0 or metal ..................... :  N 
14.3 
Inductors and windings 
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type .............................. :
Switching mode transformer  
T501: BCK-EC4201 
T502: BCK-ER2855 
Filter L512, L513: 
LCL-ET2812 
 
Transformers and inductors separately approved  : No 
14.3.2 General 
 
 
 
Page 13 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14.3.3 Constructional 
requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T501 basic insulation 
minimum 5.3 mm between 
T501 core and primary, 
Supplementary insulation 
minimum 2.9mm between 
T501 core and secondary. 
T502 basic insulation 
minimum 4.2 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.2mm between 
T502 core and secondary.
 
 
Coil formers and partition walls > 0,4 mm 
T501 bobbin: >0.8mm 
T502 bobbin: >0.8mm
 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T501 basic insulation 
minimum 5.3 mm between 
T501 core and primary, 
Supplementary insulation 
minimum 2.9mm between 
T501 core and secondary. 
T502 basic insulation 
minimum 4.2 mm between 
T502 core and primary, 
Supplementary insulation 
minimum 4.2mm between 
T502 core and secondary.
 
 
Coil formers and partition walls > 0,4 mm 
T501 bobbin: >0.8mm 
T502 bobbin: >0.8mm
 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II construction 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
No such components 
 
 
Page 14 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Fuse F501: >4.0mm 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such components 
 
b) Thermal cut-outs tested as part of the 
submission 
 N 
14.5.1.2 
a) Thermal links separately approved 
No such components 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices re-settable by soldering 
 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
F501 approved. 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : F501: T5A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : Only one fuse holder 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
 
 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such parts 
 
PTC-S devices (15 W) category V-1 or better 
 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 N 
14.6 
Switches 
No such parts 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
 N 
14.6.1 b) 
Tested in the apparatus: 
 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 N 
 
 
Page 15 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 N 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
 N 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
 N 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
 N 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 N 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
 N 
 
Socket outlet current marking correct 
 
14.7 
Safety interlocks 
No such device 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
No such device 
 
Voltage setting device not likely to be changed 
accidentally 
 N 
14.9 Motors 
 
14.9.1 
Endurance test on motors 
Only low voltage DC servo 
motor in DVD loader 
 
Motor start test 
 N 
 Dielectric 
strength 
test 
 N 
14.9.2 
Not adversely affected by oil or grease etc. 
 N 
14.9.3 
Protection against moving parts 
 N 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 N 
14.10 Batteries 
 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
Only non-rechargeable alkali 
batteries in IR remote 
controller. 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
No recharging circuit in 
apparatus 
14.10.3 
Recharging currents and times within 
manufacturers limits 
No recharging circuit in 
apparatus 
Page of 60
Display