Harman Kardon HS 500 (serv.man3) EMC - CB Certificate ▷ View online

 
 
Page 36 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
Between parts of T501 separated by basic or supplementary 
insulation 
2460Vp No 
Between parts of T502 separated by basic or supplementary 
insulation 
2630Vp No 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240 
— 
 Ambient 
temperature 
(
o
C) ...................................... : 18 
— 
Under fault conditions specified below and at power input 264V 
dT (K) 
Limit dT (K)
D514 short circuit, power consumption 8.7W, circuit protected. No high 
temperature, no hazard. Recoverable after fault removed. 
- - 
EC514 short circuit, power consumption 10.3W, circuit protected. No high 
temperature, no hazard. Recoverable after fault removed. 
- - 
D515 short circuit, power consumption 60W max, 5s, power consumption 3.3W 
circuit protected. No high temperature, no hazard. Recoverable after fault 
removed. 
- - 
EC516 short circuit, D515 damaged, power consumption 10.3W. No high 
temperature, no hazard.  
- - 
D516 short circuit, U503 damaged immediately, power consumption 1.3W. No 
high temperature, no hazard.  
- - 
D517 short circuit, power consumption 13.4W, circuit protected. No extreme high 
temperature, no hazard. Recoverable after fault removed. 
- - 
D518 short circuit, power consumption 15.0W, circuit protected. No high extreme 
temperature, no hazard. Recoverable after fault removed. 
- - 
EC521 short circuit, power consumption 13.0W, circuit protected. No high 
extreme temperature, no hazard. Recoverable after fault removed. 
- - 
R559 short circuit, power consumption 4.0W, circuit protected. No high 
temperature, no hazard. Recoverable after fault removed. 
- - 
U502 secondary short circuit, power consumption 4.0W, circuit protected. No high 
temperature, no hazard. Recoverable after fault removed. 
- - 
D519 short circuit, power consumption 51W, 2s, power consumption 10W, circuit 
protected. No high temperature, no hazard. Recoverable after fault removed. 
- - 
EC503 short circuit, power consumption 2.5W, circuit protected. No high 
temperature, no hazard. Recoverable after fault removed. 
- - 
U502 primary short circuit, power consumption 2.2W, circuit protected. No high 
temperature, no hazard. Recoverable after fault removed. 
- - 
R524 short circuit, power consumption 48W, as normal. No extreme high 
temperature, no hazard. Recoverable after fault removed. 
- - 
R525 short circuit, power consumption 20.0W, PFC no operating. No extreme 
high temperature, no hazard. Recoverable after fault removed. 
- - 
 
 
Page 37 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
R552 short circuit, amplifier board damaged, power consumption 20W. No high 
extreme temperature, no hazard.  
- - 
U504 secondary short circuit, power consumption 29W, the amplifier board no 
output. No high extreme temperature, no hazard. Recoverable after fault 
removed. 
- - 
U504 primary short circuit, power consumption 21W, the amplifier board no 
output. No high extreme temperature, no hazard. Recoverable after fault 
removed. 
- - 
U505 secondary short circuit, power consumption 19.6W, the amplifier board no 
output. No high extreme temperature, no hazard. Recoverable after fault 
removed. 
- - 
U505 primary short circuit, power consumption 48W, as normal. No high extreme 
temperature, no hazard. Recoverable after fault removed. 
- - 
EC507 short circuit, power consumption 25W, the amplifier board no output. No 
high extreme temperature, no hazard. Recoverable after fault removed. 
- - 
D511 short circuit, power consumption 24W, the amplifier board no output. No 
high extreme temperature, no hazard. Recoverable after fault removed. 
- - 
D510 short circuit, power consumption 24W, the amplifier board no output. No 
high extreme temperature, no hazard. Recoverable after fault removed. 
- - 
EC502 short circuit, F501 opened immediately, no hazard. 
DB501 short circuit, F501 opened immediately, no hazard. 
Q501: D-S short circuit, F501 opened immediately, no hazard. 
Q504: D-S short circuit, F501 opened immediately, no hazard. 
D507 short circuit, power consumption 2.7W, circuit protected. No high 
temperature, no hazard. Recoverable after fault removed.  
- - 
EC518 short circuit, D516 damaged, power consumption 5.0W. No high 
temperature, no hazard.  
- - 
EC512 short circuit, D517 damaged, power consumption 10.0W. No extreme high 
temperature, no hazard.  
- - 
Maximum volume on all loudspeakers, power consumption 161W, circuit 
protected in 10s, the power consumption down to 66W, no high temperature, no 
hazard. 
- - 
Adjust volume on all loudspeakers, and circuit no protected, power consumption 
max 112.8W, 2 hours, no high temperature, no hazard.                                        
Monitored point: PCB near heatsink (on amplifier board) 
62.1 150 
 
Winding temperature rise measurements 
 
Ambient temperature t1 (
o
C) .................................. :  
— 
 
Ambient temperature t2 (
o
C) .................................. :  
— 
 
 
 
Page 38 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14 
TABLE: list of critical components and materials 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
Mains plug for 
Europe 
Well Shin 
Technology CO., 
LTD. 
WS-019 
16A,250V~ 
DIN VDE 0620 
VDE 
Mains cord for 
Europe         
(WS-019) 
Well Shin 
Technology CO., 
LTD. 
HO5VV-F  
2×0.75mm
2
 
DIN VDE 0281-
VDE 
Mains plug for 
Europe 
LEONI 243 ~250V,2.5A 
EN 
50075 
KEMA 
Mains plug for 
UK 
KDJ Quality 
Electrical Co Ltd 
KDJ 828 
13A, 250V~ 
BS1363 
BSI 
(alternative) 
Hangzhou Fuxing 
Electrical LTD 
SW238  
SW238I 
SW238II 
13A, 250V~ 
BS1363 
BSI 
(alternative) 
Leoni (Xiamen) 
Electronics Co.  
360 ~250V, 
13A 
BS1363 
ASTA 
(alternative) 
Kaixuanfu Metal 
& Plastic Co Ltd 
HO-022  
HO-100 
250V, 13A 
BS1363 
BSI 
Mains cord for 
UK, Europe( 
243) 
Phino Electric 
Co., Ltd. 
H03VVH2-F 
2 x 0.75mm
2
 
DIN VDE 0281-
VDE 
(alternative) 
Shenzhen 
Baohing Electric 
Wire & Cable 
manufacture Co., 
Ltd. 
H03VVH2-F 
2×0,75mm
2
 
DIN VDE 0281 
VDE 
(alternative) 
LEONI (XIAMEN) 
ELECTRONICS 
CO.,  LTD 
H03VVH2-F 
2×0,75mm
2
 
DIN VDE 0281 
VDE 
Fuse-link built in 
the plug          
(for UK) 
DONGGUAN 
COOPER 
ELECTRONICS 
CO LTD 
TDC180 
13A, 240V, 
50Hz 
BS1362 ASTA 
(alternative) Pan 
Electrium 
7942 
13A, 240V, 
50Hz 
BS1362 ASTA 
(alternative) 
HANGZHOU 
FUXING 
ELECTRICAL 
LIMITED 
Richstar 13A 
13A, 240V, 
50Hz 
BS1362 BSI 
(alternative) 
HANGZHOU 
FUXING 
ELECTRICAL 
LIMITED 
Richstar 3A 
3A, 240V, 50Hz  BS1362 
BSI 
(alternative) 
DONGGUAN 
COOPER 
ELECTRONICS 
CO LTD 
TDC180 
3A, 240V, 50Hz  BS1362 
ASTA 
 
 
Page 39 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
Power Connector  
Well Shin 
Technology CO., 
LTD. 
WS-002E 
10A, 250V~ 
IEC 60320 
VDE 
Power Inlet  
Well Shin 
Technology CO., 
LTD. 
WS-044-0 
10A, 250V~ 
IEC 60320 
VDE 
Fuse 
F501 
Zhong Shan Lan 
Bao Electrical 
Appliances 
RTI-20 T5AL/250V 
IEC 
60127 
VDE 
(alternative) 
Hollyland Co., 
Ltd. 
50T T5AL/250V 
IEC 
60127 
VDE 
(alternative) 
Shanghai 
Songshan 
Electronic Co., 
Ltd. 
RF1-20 T5AL/250V 
IEC 
60127 
VDE 
Capacitor  C501, 
C503 
Wuxi Huatong 
Electronic Co., 
Ltd 
  
MKP 
   
~300V, 0.22μF 
40/085/21/C, X2
IEC 60384-14 
2:nd Ed. 
VDE 
(alternative) 
EUROPTRONIC 
(TAIWAN) 
INDUSTRIAL 
CORP 
MPX 
~275V, 0.22μF 
40/100/21/C, X2
IEC 60384-14 
2:nd Ed. 
NEMKO 
(alternative) 
CARLI 
ELECTRONICS 
CO LTD 
MPX 
~275V, 0.22μF 
40/100/21/C, X2
IEC 60384-14 
2:nd Ed. 
VDE 
Capacitor C502 
Wuxi Huatong 
Electronic Co., 
Ltd 
  
MKP 
   
~275V, 0.33μF 
40/085/21/C, X2
IEC 60384-14 
2:nd Ed. 
VDE 
(alternative) 
EUROPTRONIC 
(TAIWAN) 
INDUSTRIAL 
CORP 
MPX 
~275V, 0.33μF 
40/100/21/C, X2
IEC 60384-14 
2:nd Ed. 
NEMKO 
(alternative) 
CARLI 
ELECTRONICS 
CO LTD 
MPX 
~275V, 0.33μF 
40/100/21/C, X2
IEC 60384-14 
2:nd Ed. 
VDE 
Capacitor 
CY1, CY2, 
CY501, CY502 
 
PAN OVERSEAS 
ELECTRONIC 
CO LTD 
AH 
400V~, 2200pF 
25/125/21/C,Y1 
IEC 60384-14 
2:nd Ed. 
SEMKO 
(alternative) 
SHANTOU S E Z 
SONGTIAN 
ELECTRONIC 
CO LTD 
CD 
400V~, 2200pF 
25/085/21/C,Y1 
IEC 60384-14 
2:nd Ed. 
VDE 
Optocoupler 
U502, U504, 
U505 
Sharp 
Corporation 
PC817 
Internal DTI 
>0.4mm 
int./ext. Cl. &Cr. 
>4mm / 
≥6mm 
DIN VDE 0884 
VDE 
Page of 60