DOWNLOAD Harman Kardon HS 350 (serv.man3) Service Manual ↓ Size: 4.39 MB | Pages: 61 in PDF or view online for FREE

Model
HS 350 (serv.man3)
Pages
61
Size
4.39 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-350-sm3.pdf
Date

Harman Kardon HS 350 (serv.man3) EMC - CB Certificate ▷ View online

 
                                                                   Page 24 of 60                        Report No. JSH007120244-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
Biblio-
graphy 
Add 
the following standards: 
EN 50332-1:2000, Sound system equipment: Headphones and earphones 
associated with portable audio equipment — Maximum sound pressure level 
measurement methodology and limit considerations — Part 1: General method 
for "one package equipment" 
prEN 50332-2 (under consideration), Sound system 
equipment: Headphones and earphones associated with portable audio 
equipment — Maximum sound pressure level measurement methodology and 
limit considerations — Part 2: 
Guidelines to associate sets with headphones coming from different 
manufacturers
 
N/A  
 
Add 
the following notes for the standards indicated: 
IEC 60130 
NOTE Parts 9 and 17:1998 are harmonized as ENs (not modified). 
IEC 60169 
NOTE Partly harmonized in the EN 60169/HD 134 series (not modified). 
IEC 60173 
NOTE Harmonized as HD 27 S1:1978 (not modified). 
IEC 60335-2-56 
NOTE Harmonized as EN 60335-2-56:1997 (not modified)
IEC 60335-2-82 
NOTE Harmonized as EN 60335-2-82:2000 (not modified)
IEC 60695 
NOTE Harmonized as EN 60695 series (not modified). 
IEC 61040 
NOTE Harmonized as EN 61040:1992 (not modified). 
IEC 61558-2-1 
NOTE Harmonized as EN 61558-2-1:1997 (not modified). 
IEC 61558-2-4 
NOTE Harmonized as EN 61558-2-4:1997 (not modified). 
IEC 61558-2-6 
NOTE Harmonized as EN 61558-2-6:1997 (not modified).
 
Pass  
 
 
ZB 
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS 
 
2.6.1 
DK: certain types of Class I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
Class II 
N/A 
13.3.1 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 Pass 
15.1.1 
DK: mains cord for single-phase equipment having 
a rated current not exceeding 10 A shall be 
provided with a plug according to Heavy Current 
Regulations Section 107-2-D1 
         
 Pass 
 
DK: Class I equipment with socket-outlets with 
earthing contact, or which are intended to be used 
in locations where protection against indirect 
contact is required shall be provided with a plug in 
compliance with Standard Sheet DK 2-1a 
         
 N/A 
 
                                                                   Page 25 of 60                        Report No. JSH007120244-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
DK: socket-outlets for providing power to Class II 
equipment with a  rated current of 2,5 A shall have 
dimensions according to the drawing on page 131 
of EN 60 065:98 other dimensions shall be to 
IEC 60 083 Standard Sheet C 1a for portable 
socket-outlets 
         
 N/A 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
         
 N/A 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
 Pass 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
         
 Pass 
 
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the 
following amendments: 
N/A 
 
- dimensions 2,5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60 065:98 
         
 N/A 
 
- mechanical strength 2,5 A, 250 V socket-outlets 
tested as specified in EN 60 065, 12.1.3 
         
 N/A 
 
- protecting rim also tested 
         
 N/A 
 
NO: method b) of 8.1 is not permitted. Double or 
reinforced insulation is required between parts 
connected to the mains and parts connected to the 
public telecommunications network 
         
 N/A 
J.2 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 Pass 
 
 
ZC 
ANNEX ZC TO EN 60 065, A-DEVIATIONS 
 
DE: additional markings required in German language: 
 
 
- cathode ray tubes with an accelerating voltage 
between 20 kV and 30 kV (marking on the tube) 
No CRT used. 
N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage between 20 kV and 30 kV 
         
 N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage greater than 30 kV 
         
 N/A 
 
                                                                   Page 26 of 60                        Report No. JSH007120244-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
         
 N/A 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
         
 N/A 
 
IT: user instructions in Italian language including a 
conformity declaration 
         
 N/A 
 
IT: certification number on the back cover 
         
 N/A 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
No such switch used. 
Pass 
 
 
Amendment 1 to EN60065, 7th edition 
 
5.4.1 
A warning that batteries (battery pack or batteries 
installed) shall not be exposed to excessive heat 
such as sunshine, fire or the like. 
 N/A 
 
Special stability warning for the apparatus with 
CRT 
Warning: the CRT in this product employs a 
protective film on the face. This film must not be 
removed as it serves a safety function and removal 
will increase the risk of serious injury. 
 N/A 
8.7 Void 
 
N/A 
8.8 
For requirements for non-separable thin sheet 
insulation in two or more layers, see 8.22. 
 N/A 
8.22 
Requirements for non-separable thin sheet 
insulation in two or more layers 
 N/A 
15.2 
Delete the paragraph:  In supply apparatus of 
Class I with non-hazardous live output voltage: 
output circuit shall not be connected to the 
protective earthing conductor. 
 N/A 
18.1 
Protective film as part of the implosion protection 
system:  all edges covered by the enclosure of the 
apparatus 
 N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability. 
 N/A 
20.1 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 Pass 
 
b) Exemption for small components as defined in 
20.1 excluding metal, glass and ceramic. 
 Pass 
 
                                                                   Page 27 of 60                        Report No. JSH007120244-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
5.1 
TABLE: rated current/power consumption 
Pass 
 
Model  
Input voltage 
(V) 
Rated 
current 
(mA) 
Measured 
current 
(mA) 
Rated 
power (W) 
Measured 
power (W) 
condition/status 
240  - 
230 230 43.7 
HS 350 
100  - 
450 230 43.8 
Normal DVD playing 
 
 
 
 
 
 
 
 
 
 
 
 
 
7.1 
TABLE: temperature rise measurements  
Pass 
 
Power consumption in the OFF/Stand-by 
0W/2.1W max. 
— 
 
Position of the functional switch (W) ...................... :
On 
— 
 
Room temperature t1 (°C)  ...................................:
21.5 
 
 
Room temperature t2 (°C)  ...................................:
21.5 
 
 
Operating conditions 
Normal DVD playing, with 1/8 non-clipped 400Hz sinusoidal output power to the speaker, operates 4 hours 
until steady condition reached.  
Un (V) 
In (mA)  
Pn (W)  
Pout (V / mA) 
264 220 
43.7 
N.A. 
90 500 
44.9 
N.A. 
 
         
 
Loudspeaker impedance (Ω) ................................. : 6 Ω X 5 
— 
         
 
Several loudspeaker systems 
5 channel speakers 
Pass 
         
 
Marking of loudspeaker terminals 
Printed on rear enclosure 
Pass 
dT (K) 
monitored point: 
264 
90 
Permitted dT (K) 
Connector(CN701) 16.8 
20.8 
CX703 (X2 capacitor ) 
20.1 
25.7 
60 (85-25) 
Winding of LF705 
21.0 
25.1 
75* 
CX702 (X2 capacitor ) 
24.0 
26.3 
60 (85-25) 
Winding of LF704 
20.4 
22.9 
75* 
PCB near BD701 
27.1 
30.7 
85 
PCB near Q703 
26.9 
29.5 
85 
Winding of LF703 
26.4 
32.7 
75* 
Page of 61
Display

Click on the first or last page to see other HS 350 (serv.man3) service manuals if exist.