Harman Kardon HS 350 (serv.man3) EMC - CB Certificate ▷ View online
Page 20 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
See components list
Pass
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
See components list
Pass
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No voltage exceeding 4Kv
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
Rated: V-0
Pass
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
Rated: V-0
Pass
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
See components list
Pass
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 21 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
IP20
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2 Humidity
treatment carried out for 7 days
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
Not to be connected to the
telecommunication networks
telecommunication networks
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Page 22 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60065:2002)
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60065:2002)
3.1
Add
the following indent at the end of the list:
- exposure to excessive sound pressures from
headphones or earphones.
headphones or earphones.
NOTE A new method of measurement is described in EN
50332-1, Sound system equipment:
Headphones and earphones associated with portable audio
equipment - Maximum sound pressurelevel measurement
methodology and limit considerations - Part 1: General
method for "one package equipment”, and in EN 50332-2,
Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound
pressure level measurement methodology and limit
considerations - Part 2: Guidelines to associate sets with
headphones coming from different manufacturers.
N/A
4.1.1
Replace
the text of the note by:
NOTE For ROUTINE TEST reference is made to EN 50333.
N/A
5.1.i)
Add
the following note:
NOTE For RATED POWER CONSUMPTION measurements
of TVs reference is made to
EN 60107.
N/A
6.1
Replace
the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under
fault conditions.
Compliance is checked by measurement under
the following conditions
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under
fault conditions.
Compliance is checked by measurement under
the following conditions
:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Soldered joints and paint lockings are examples of
adequate locking.
N/A
Page 23 of 60 Report No. JSH007120244-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
6.1
(Cont)
The amount of ionizing radiation is regulated by
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any
point 10 cm from the outer surface of the
apparatus, the dose-rate shall not exceed
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any
point 10 cm from the outer surface of the
apparatus, the dose-rate shall not exceed
1µSv/h (0,1 mR/h) taking account of the
background level.
background level.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
A picture is considered to be intelligible if the
following conditions are met:
following conditions are met:
- a scanning amplitude of at least 70 % of the
usable screen width;
usable screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1,5 MHz in the centre, with a similar vertical
degradation;
1,5 MHz in the centre, with a similar vertical
degradation;
- not more than one flashover per 5 min.
N/A
13.3.1
Delete note 4.
Pass
14
Delete note 4 and note 5.
Pass
15.1.1
Delete note 1 and note 2.
Pass
15.2
Delete note 2.
Pass
16.1
Delete note 1.
Pass
16.2
Delete the note.
Pass
20
Delete note 2.
Pass
Annex B
Replace note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
special national conditions apply.
N/A
Annex G
Delete the note.
N/A
Annex J.2 Delete the notes of Table J.1
N/A
Annex N
Add after the introduction:
For ROUTINE TEST reference is made to EN
50333.
50333.
N/A
Click on the first or last page to see other HS 350 (serv.man3) service manuals if exist.