DOWNLOAD Harman Kardon HS 2X0 (serv.man4) Service Manual ↓ Size: 5.75 MB | Pages: 107 in PDF or view online for FREE

Model
HS 2X0 (serv.man4)
Pages
107
Size
5.75 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-2x0-sm4.pdf
Date

Harman Kardon HS 2X0 (serv.man4) EMC - CB Certificate ▷ View online

 
Test report no. SH09100839-001 
 
 
Page 80 of 106 
TRF55013a/effective date: September 15
th
, 2009 
15. Measurement of screening effectiveness (S4) 
Test result: PASS 
 
15.1 Limits and Performance Criterion 
15.1.1 Limits 
 
15.1.2 Performance Criterion   
   Performance criterion A 
 
 
15.2 Block Diagram of Test Setup 
Radio receiver: 
 
 
Test report no. SH09100839-001 
 
 
Page 81 of 106 
TRF55013a/effective date: September 15
th
, 2009 
 
Television Receiver: 
 
 
15.3 Test Setup and Test Procedure 
 
Measurement was performed in shielded room. 
Instruments used were following CISPR 16-1 and EN 55020. 
Measurement methods and operation conditions of EUT was according to clause 5.1, 
5.2 and 5.5 of EN55020. 
 
15.4 Test Protocol
 
 
Temperature  
22
°C  
Relative Humidity: 
54% 
 
Frequency (MHz) 
Limit level (dB) 
Test level (dB) 
Results (pass/fail) 
98.00 20  40.0 PASS 
 
 
15.5 Additions, Deviations and Exclusions from Standards 
 
None
 
 
 
 
Test report no. SH09100839-001 
 
 
Page 82 of 106 
TRF55013a/effective date: September 15
th
, 2009 
16. Electrostatic Discharge (ESD) 
 
Test result 
PASS 
 
16.1 Severity Level and Performance Criterion 
16.1.1 Test level 
1a – Contact discharge 
 
1b – Air discharge 
Level 
 
Test voltage 
kV 
Level Test 
voltage 
 kV 
3 6 3 
4 8 4 15 
 X 
Special 
  X  
Special 
 
Notes: 1. “X” is an open level. The level has to be specified in the dedicated             
equipment specification. If higher voltages than those shown are specified, special 
test equipment may be needed. 
           2. The gray rows were the selected test level. 
 
 
16.1.2 Performance Criterion   
Performance criterion: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Test report no. SH09100839-001 
 
 
Page 83 of 106 
TRF55013a/effective date: September 15
th
, 2009 
 
16.2 Block Diagram of Test Setup 
 
 For table-top equipment 
 
 
Note: HCP means Horizontal Coupling Plane 
VCP means Vertical Coupling Plane 
GRP means Ground Reference Plane 
Wooden support is a 0.8m height table 
 
 
 For floor standing equipment 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note: VCP means Vertical Coupling Plane 
GRP means Ground Reference Plane 
Wooden support is a 0.1m height rack 
 
EMC simulator 
ESD gun 
 
   EUT & AE 
 
VCP
GRP 
470k
Ω 
Resistor 
Insulate  
Support 
  HCP 
Wooden support 
ESD 
simulator 
ESD gun 
 
   EUT &AE 
 
VCP 
470k
Ω 
Resistor 
Wooden support 
GRP 
Page of 107