Report No. JSH006110476-001 
Page 20 of 69 
5. Continuous Disturbance Power 
 
Test   result: 
Pass 
 
 
5.1 Disturbance Power Limits for the frequency range 30MHz to 300MHz 
 
 
Frequency (MHz) 
 
Quasi-peak 
dB(pW) 
Average 
 dB (pW) 
30 to 300 
 
45 to 55* 
35 to 45* 
 
Note: 1. * means the limit increasing linearly with the frequency. 
          2. If the limit for the measurement with the average detector is met when using a receiver  
             with a quasi-peak detector, the equipment under test shall be deemed to meet both limits  
             and the measurement with the receiver with average detector need not be carried out. 
 
 
Report No. JSH006110476-001 
Page 21 of 69 
 
 
5.2 Block Diagram of Test Setup 
 
 
 
Note: 
 
: power line 
 
  : 
signal 
lime 
 
 
5.3 Test Setup and Test Procedure 
 
The disturbance power was measured with the EUT in a shielded room. 
The EUT was placed on a non-metallic table at least 0.4m from other metallic surface and the 
mains  
lead of EUT was extended to about 6m long. The absorbing clamp was moved along the lead to 
obtain  
maximum disturbance.  
The EUT was set to achieve the maximum emission level, and for each point which appears a 
relevant  
high emission level, the absorbing clamp was moved around the lead to get the maximum 
disturbance  
value. 
 
The bandwidth of test receiver was set at 120kHz. 
  The frequency range from 30MHz to 300MHz was checked. 
Amplitude measurements were performed with a quasi-peak detector and, if necessary, with an  
average detector. 
Absorbing clamp 
moved over power 
cord to obtain max. 
reading o receiver 
Absorbing 
clamp 
Mains 
Absorber 
(ferrite rings)
 
Current 
transformer 
Absorber 
(ferrite rings)
 
            
 
 
E U T  
Transform
The transformer to provide 
a stable voltage to the EUT
during the test.
 
Radio 
noise meter
 
Report No. JSH006110476-001 
Page 22 of 69 
 
5.4 Test Protocol 
 
Temperature  
22   
°C 
   
Relative Humidity 
43   % 
At mains terminal 
 
 
At other leads  
AV Line 
 
 
Report No. JSH006110476-001 
Page 23 of 69 
 
 
 
 
5.5 Measurement Uncertainty 
 
The measurement uncertainty describes the overall uncertainty of the given measured value   
during  the operation of the EUT. 
Measurement uncertainty is calculated in accordance with CISPR 16-4-2:2003 
 Measurement uncertainty of mains terminal disturbance power : 
±4.5dB 
The measurement uncertainty is given with a confidence of 95%, k=2 
 
5.6 Additions, Deviations and Exclusions from Standards  
 
 None 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 