Harman Kardon HS 200 (serv.man6) EMC - CB Certificate ▷ View online

 
Report No. JSH006110476-001 
Page 12 of 69 
 
3.2 Block Diagram of Test Setup 
 
For AV product 
 
     
 
 
Set up at antenna terminal  
 
 
 
 
 
 
 
 
 
 
 
 
 
Report No. JSH006110476-001 
Page 13 of 69 
3.3 Test Setup and Test Procedure 
 
 
The EUT was set to achieve the maximum emission level. 
The mains terminal disturbance voltage was measured with the EUT in a shielded room. 
The EUT was connected to AC power source through an Artificial Mains Network which provide 
a  50
Ω linear impedance  
 
 Artificial hand is used if appropriate.    
 
The load/control terminal disturbance voltage was measured with passive voltage probe. 
 
For  Table top 
  
 
The EUT was placed on a 0.8m high non-metallic table above a metallic plane, The wall of 
shielded room used as Ground Reference Plane (GRP) 
 
For  Floor standing         
 
The EUT was placed on a 0.1m high non-metallic support above a metallic plane, The wall of 
shielded room used as Ground Reference Plane (GRP) 
 
For Both Table Top and Floor Standing 
 
The EUT keeps a distance of at least 0.8m from any other of the metallic surface. The Artificial 
Mains Network is situated at a distance of 0.8m from the EUT.  
During the test, mains lead of EUT excess 0.8m was folded back and forth parallel to the lead so as 
to form a horizontal bundle with a length between 0.3m and 0.4m. 
 
The bandwidth of test receiver ESCS 30 was set at 9kHz. 
 
The frequency range from 150kHz to 30MHz was checked. 
 
Amplitude measurements were performed with a quasi-peak detector and , if necessary ,with an  
average detector. 
 
For antenna terminal 
 
The measurement was preceded in a shielded room. 
The antenna terminals of the equipment under test and the auxiliary signal generator were 
connected to the measuring receiver by means of coaxial cables and a resistive combining network 
having a minimum attenuation of 6 dB. 
The impedance as seen from the equipment under test was equal to the nominal antenna input 
impedance for which the equipment under test has been designed (75
Ω). 
The output level of the auxiliary signal generator was set to give 70dB(uV) at the input of the 
equipment under test and the signal was an unmodulated carrier. 
 
Report No. JSH006110476-001 
Page 14 of 69 
3.4 Test Protocol 
Temperature  
25 
°C 
   
Relative Humidity 
52 %
 
      The worst result during FM mode and DVD playing mode 
 
 
At antenna terminal FM mode: Pass 
Frequency (MHz) 
Disturbance level 
dB(
µV) 
Permitted limit 
dB(
µV) 
Fundamental(<=1000) */*/* 
46 
Harmonics(30-950) */*/* 
46 
Harmonics(950-2150) */*/* 
54 
Other(30-2150) */*/* 
46 
Note: * means the emission level 10dB lower than the relevant limit. 
 
 
3.5 Measurement Uncertainty 
 
The measurement uncertainty describes the overall uncertainty of the given measured value  
during the operation of the EUT. 
Measurement uncertainty is calculated in accordance with CISPR 16-4-2: 2003. 
Measurement uncertainty of mains terminal disturbance voltage : 
± 3.6dB 
The measurement uncertainty is given with a confidence of 95%, k=2.
 
 
3.6 Additions, Deviations and Exclusions from Standards  
 None. 
 
Report No. JSH006110476-001 
Page 15 of 69 
 
4. Radiated emission 
 
Test result:   PASS 
 
4.1 Radiated emission limit from frequency range 30MHz – 1000MHz 
 
According to EN 55013 
Equipment type 
Source 
Frequency (MHz) 
Limit value dB(
µV/m) 
Quasi-peak 
Television receiver, 
video recorder and PC 
tuner cards 
Local Oscillator 
 
 
Other 
 
<=1000 
30 to 300 
300 to 1000 
30 to 230 
230 to 1000 
Fundamental            57* 
Harmonic                 52 
Harmonic                 56 
                                 40 
                                 47 
Television receiver, and 
receivers for broadcast 
satellite transmission, 
(except outdoor unit) 
Infrared remote control 
units and infrared 
headphone system 
Other 
 
30 to 230 
230 to 1000 
                                 40 
                                 47 
Frequency modulation 
sound receivers and PC 
tuner cards 
Local oscillator 
 
 
Other 
 
<=1000 
30 to 300 
300 to 1000 
.30 to 230 
230 to 1000 
Fundamental            60 
Harmonic                 52 
Harmonic                 56 
                                 40 
                                 47 
* in Japan, the limit 57dB
µV/m is relax to 66dBµV/m for operation channel <300MHz and to 70dBµV/m 
for operation channel >300MHz. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 70