                                                                               Page 2 of 63                                  Report No. SH09051259-001 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
Manufacturer ...................................... :  Same as applicant. 
Factory................................................ :  WANLIDA GROUP CO., LTD. 
WANLIDA INDUSTRY ZONE, NANJING, FUJIAN, CHINA. 363601 
Rating(s)............................................. :  100-240V ~ 50/60Hz, 300W, Class II 
Copy of marking plate 
 
On DVD loader: 
       
 
      
 
 
 
Summary of Testing and Conclusions: 
 
From the result of our examination and tests in the submitted samples, conclude they comply with the 
requirements of the standard EN 60065_2002+A1_2006. 
 
In this report, the test record for the alternative components, such as T502, T503, LF501, LF502 have been 
considered the most rigorous result. 
 
 
                                                                               Page 3 of 63                                  Report No. SH09051259-001 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
Test case verdicts 
Test case does not apply to the test object..................:
N/A 
Test item does meet the requirement...........................:
P(ass) 
Test item does not meet the requirement.....................:
F(ail) 
Testing 
Date of receipt of test item  ...........................................:
May 17, 2009 
Date(s) of performance of test ......................................:
May 17, 2009 – June 01, 2009
 
General remarks
 
 
This report shall not be reproduced except in full without the written approval of the testing laboratory. 
 
The test results presented in this report relate only to the item(s) tested. 
 
Determination of the test result includes consideration of measurement uncertainty from the test equipment 
and methods. 
 
"(see appended table)" refers to a table appended to the report. 
“(see remark #)” refers to a remark appended to the report. 
“(see Annex #) refers to an annex appended to the report. 
 
Throughout this report a point is used as the decimal separator. 
 
General product information: 
 
N.A 
 
 
 
                                                                  Page 4 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus ................................. : Class II 
Pass 
 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 
Ventilation instructions require the use of the test 
box 
Yes Pass 
 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
Printed on the rear enclosure 
Pass 
 
Permanent durability against water and petroleum 
spirit 
 Pass 
5.1 
Identification, maker, model  ................................... : harman/kardon 
Pass 
 
Class II symbol if applicable 
 
Pass 
 
Rated supply voltage and symbol .......................... : 100-240V ~ 
Pass 
 
Frequency if safety dependant 
50/60Hz 
Pass 
 
Rated current or power consumption  .................... : 300W 
Pass 
5.2 Earth 
terminal 
Class 
II 
N/A 
 
Hazardous live terminals 
 
N/A 
 
Supply output terminals (other than mains) 
 
N/A 
5.3 
Use of triangle with exclamation mark 
On PCB  
Pass 
5.4 Instructions 
for 
use 
 
Pass 
5.4.1 
Mains powered equipment not exposed to dripping 
or splashing. Warning concerning objects filled 
with liquid, etc. 
 Pass 
 
Hazardous live terminals, instructions for wiring 
No such terminals 
N/A 
 
Instructions for replacing lithium battery 
No lithium battery 
N/A 
 
Instructions for modem if fitted 
No modem fitted 
N/A 
 
Class I earth connection warning 
 
N/A 
 
Instructions for multimedia system connection 
 
Pass 
 
Special stability warning for fixed installation 
 
N/A 
5.4.2 
Disconnect device: plug/coupler or all-pole mains 
switch location, accessibility and markings 
 Pass 
 
Instructions for permanently connected equipment  
N/A 
 
                                                                  Page 5 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation 
N/A 
6.1 
EN 60065 
European Council Directive 96/29/Euratom of 13 
May 1996 10cm from outer surface of apparatus 
<1µSv/h (0,1mR/h) 
No ionizing radiation 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  .... : Class 1 
Pass 
 
Emission limits under fault conditions .................... : Laser Optical Pickup: Class 1 
Pass 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table) 
Pass 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
Pass 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
Pass 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table) 
Pass 
7.1.4 
Temperature rise of windings 
(see appended table) 
Pass 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
Pass 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No such supporting parts 
N/A 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
PCB, windings 
Pass 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Tools are required 
Pass 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used 
Pass 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
Tools are required 
Pass 
8.5 
Class I equipment 
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 